Thai Pharmacopoeia · TP-2011-Supplement-2024
Coriander Oil
น้ำมันลูกผักชี
Definition
Thai name ชื่อหมวดหลัก (NAM MAN LUK PHAK CHI) Category Carminative; pharmaceutical aid. Coriander Oil is the volatile oil distilled with steam from the dried ripe fruit of Coriandrum sativum L. (Family Umbelliferae). Constituents Coriander Oil contains predominantly monoterpene alcohols as linalool. It also contains terpenes (e.g., $ \alpha $ -pinene, limonene, $ \gamma $ -terpinene), and camphor. Description Clear colourless or pale yellow liquid odourless. Solubility test Soluble, at $ 2 0^{\circ} $ in 3 volumes of ethanol (70 per cent). Packaging and storage Coriander Oil shall be kept in well-filled, tightly closed containers, protected from light, and stored at a temperature not exceeding 25 $ ^{\circ} $ . ## Identification Carry out the test as described in the "Thin-Layer Chromatography" (Appendix 3.1). Standard solution Dissolve 10 $ \mu\mathrm{L} $ of linalool, and 2 $ \mu\mathrm{L} $ of geranyl acetate in 1.0 mL of toluene. Test solution Dissolve 10 $ \mu\mathrm{L} $ in toluene and dilute to 1.0 mL with the same solvent. Adsorbent Silica gel F254 (TLC or HPLC plate). Mobile phase Ethyl acetate and toluene (5:95). Application Apply 10 $ \mu\mathrm{L} $ (or 2 $ \mu\mathrm{L} $ ) each of Standard solution and Test solution as 15-mm (or 8-mm) bands. Development and drying Allow the solvent front to ascend 10 cm (or 6 cm) above the line of application. Dry the developed plate in air for 5 minutes. Results When examined under visible light, the test solution shows a violet band due to linalool in the lower third, corresponding in colour and $ R_{\mathrm{f}} $ to the band shown by the standard solution. A violet-blue band near the starting line and a bluish violet band in the upper third of the chromatogram is present. Detection Spray the plate with anisaldehyde TS, heat at 105 $ ^{\circ} $ for 5 minutes and examine under visible light Observe the result. The retention time of the major peaks in the chromatogram of the Coriander Oil correspond to
Monograph text
Category
Carminative; pharmaceutical aid. Coriander Oil is the volatile oil distilled with steam from the dried ripe fruit of Coriandrum sativum L. (Family Umbelliferae).
Constituents
Coriander Oil contains predominantly monoterpene alcohols as linalool. It also contains terpenes (e.g., α -pinene, limonene, γ -terpinene), and camphor.
Description
Clear colourless or pale yellow liquid odourless.
Solubility
test Soluble, at 2 0° in 3 volumes of ethanol (70 per cent).
Packaging and storage
Coriander Oil shall be kept in well-filled, tightly closed containers, protected from light, and stored at a temperature not exceeding 25° .
Identification
Carry out the test as described in the "Thin-Layer Chromatography" (Appendix 3.1). Standard solution Dissolve 10 μL of linalool, and 2 μL of geranyl acetate in 1.0 mL of toluene. Test solution Dissolve 10 μL in toluene and dilute to 1.0 mL with the same solvent. Adsorbent Silica gel F254 (TLC or HPLC plate). Mobile phase Ethyl acetate and toluene (5:95). Application Apply 10 μL (or 2 μL ) each of Standard solution and Test solution as 15-mm (or 8-mm) bands. Development and drying Allow the solvent front to ascend 10 cm (or 6 cm) above the line of application. Dry the developed plate in air for 5 minutes. Results When examined under visible light, the test solution shows a violet band due to linalool in the lower third, corresponding in colour and R_{f} to the band shown by the standard solution. A violet-blue band near the starting line and a bluish violet band in the upper third of the chromatogram is present. Detection Spray the plate with anisaldehyde TS, heat at 105° for 5 minutes and examine under visible light Observe the result. The retention time of the major peaks in the chromatogram of the Coriander Oil correspond to those in the chromatogram of the Standard solution (a), as obtained in the Chromatographic profile. Specific gravity 0.860 to 0.880 (Appendix 4.9). Optical rotation + 7° to + 13° (Appendix 4.8). Refractive index 1.462 to 1.470, at 20° (Appendix 4.7). Acid value Not more than 3.0; use 5 g (Appendix 5.4) Chromatographic profile Carry out the test as described in the "Gas Chromatography" (Appendix 3.4) Standard solution (a) Dissolve 10 μL of a-pinene, 10 μL of limonene, 10 μL of γ -terpinene, 10 μL of p-cymene, 10 mg of camphor, 20 μL of linalool, 10 μL of a-terpineol, 10 μL of geranyl acetate and 10 μL of geraniol in 1 mL of heptane. Standard solution (b) Dissolve 5 μL of geraniol in heptane and dilute to 10.0 mL with the same solvent. Test solution Use Coriander oil. Chromatographic system DETECTOR Flame ionization COLUMN A fused-silica capillary column (60 m \times 0.25 mm) packed with macrogol 20000 (0.25 μm ). TEMPERATURE Column The temperature programme is as follows: <table border="1"><tr><td>Time(Minutes)</td><td>Temperature(°)</td></tr><tr><td>0-10</td><td>60</td></tr><tr><td>10-75</td><td>60→190</td></tr><tr><td>75-120</td><td>190</td></tr></table> Injection port 220° Detector 240° CARRIER GAS Helium SPLIT RATIO 1:65 FLOW RATE 1 mL per minute System suitability SAMPLE Standard solution (a) Suitability requirements RESOLUTION Not less than 1.5 between linalool and camphor peaks. Procedure Inject a portion (about 0.2 mL) of Standard solution (a), Standard solution (b) and Test solution into the chromatograph. Identify the peaks due to the components in Coriander Oil, using the retention times determined from the chromatogram obtained from the standard solution (a). Measure the areas of the principal peaks in the chromatogram obtained from the Coriander Oil. Calculation Calculate the percentage content of the components of Coriander Oil taken by normalization procedure.
Limits
- a-pinene: 3.0 per cent to 7.0 per cent. - limonene: 1.5 per cent to 5.0 per cent. - γ -terpinene: 1.5 per cent to 8.0 per cent. - p-cymene: 0.5 per cent to 4.0 per cent. - camphor: 3.0 per cent to 6.0 per cent. - linalool: 65.0 per cent to 78.0 per cent. - a-terpineol: 0.1 per cent to 1.5 per cent. - geranyl acetate: 0.5 per cent to 4.0 per cent. - geraniol: 0.5 per cent to 3.0 per cent. - disregard limit: area of the peak in the chromatogram obtained from the standard solution (b) (0.05 per cent). Chiral purity Not more than 14 per cent of (R)-linalool. Carry out the test as described in the "Gas Chromatography" (Appendix 3.4). Standard solution Dissolve 10 μL of linalool and 5 mg of borueol in pentane and dilute to 10.0 mL with the same solvent. Test solution Dissolve 20 mg of Coriander Oil in pentane and dilute to 10.0 mL with the same solvent. Chromatographic system DETECTOR Flame ionization COLUMN A fused-silica capillary column (25 m \times 0.25 mm) packed with modified b-cyclodextrin for chiral chromatography (0.25 \mum). TEMPERATURE Column The temperature programme is as follows: <table border="1"><tr><td>Time(Minutes)</td><td colspan="2">Temperature(°)</td></tr><tr><td>0-65</td><td colspan="2">50→180</td></tr><tr><td colspan="3">Injection port230°Detector230°CARRIER GASHeliumSPLIT RATIO1:30FLOW RATE1.3mL per minute</td></tr><tr><td colspan="3">System suitabilitySAMPLEStandard solution</td></tr><tr><td colspan="3">Suitability requirementsRESOLUTIONNot less than5.5between(R)-linalo first peak)and(S)-linalool(second peak)and not less than2.9between the peaks due to(S)-linalool and</td></tr></table> borneol (third peak). Procedure Separately inject equal volumes (about 1 μL ) of Standard solution and Test solution into the chromatograph. Measure the responses for the major peaks. Calculation Calculate the percentage content of (R)-linalool using the expression: \frac {A _ {R}}{A _ {S} + A _ {R}} \times 1 0 0 \mathrm{A_{S}} = area of the peak due to (S)- linalool; A_{R} area of the peak due to (R)- linalool.
Same substance in other pharmacopoeias
View raw JSON-LD
{
"@id": "https://www.openphar.org/data/tp/monographs/coriander-oil",
"@type": "IndexedMonograph",
"prefLabel": {
"en": "Coriander Oil",
"th": "น้ำมันลูกผักชี"
},
"edition": "TP-2011-Supplement-2024",
"category": "monographs",
"definition": {
"en": "Thai name ชื่อหมวดหลัก (NAM MAN LUK PHAK CHI)\n\nCategory Carminative; pharmaceutical aid.\n\nCoriander Oil is the volatile oil distilled with steam from the dried ripe fruit of Coriandrum sativum L. (Family Umbelliferae).\n\nConstituents Coriander Oil contains predominantly monoterpene alcohols as linalool. It also contains terpenes (e.g., $ \\alpha $ -pinene, limonene, $ \\gamma $ -terpinene), and camphor.\n\nDescription Clear colourless or pale yellow liquid odourless.\n\nSolubility test Soluble, at $ 2 0^{\\circ} $ in 3 volumes of ethanol (70 per cent).\n\nPackaging and storage Coriander Oil shall be kept in well-filled, tightly closed containers, protected from light, and stored at a temperature not exceeding 25 $ ^{\\circ} $ .\n\n## Identification\n\nCarry out the test as described in the \"Thin-Layer Chromatography\" (Appendix 3.1).\n\nStandard solution Dissolve 10 $ \\mu\\mathrm{L} $ of linalool, and 2 $ \\mu\\mathrm{L} $ of geranyl acetate in 1.0 mL of toluene.\n\nTest solution Dissolve 10 $ \\mu\\mathrm{L} $ in toluene and dilute to 1.0 mL with the same solvent.\n\nAdsorbent Silica gel F254 (TLC or HPLC plate). Mobile phase Ethyl acetate and toluene (5:95).\n\nApplication Apply 10 $ \\mu\\mathrm{L} $ (or 2 $ \\mu\\mathrm{L} $ ) each of Standard solution and Test solution as 15-mm (or 8-mm) bands.\n\nDevelopment and drying Allow the solvent front to ascend 10 cm (or 6 cm) above the line of application.\n\nDry the developed plate in air for 5 minutes.\n\nResults When examined under visible light, the test solution shows a violet band due to linalool in the lower third, corresponding in colour and $ R_{\\mathrm{f}} $ to the band shown by the standard solution. A violet-blue band near the starting line and a bluish violet band in the upper third of the chromatogram is present.\n\nDetection Spray the plate with anisaldehyde TS, heat at 105 $ ^{\\circ} $ for 5 minutes and examine under visible light Observe the result.\n\nThe retention time of the major peaks in the chromatogram of the Coriander Oil correspond to"
},
"sections": [
{
"name": "Category",
"text": "Carminative; pharmaceutical aid.\nCoriander Oil is the volatile oil distilled with steam from the dried ripe fruit of Coriandrum sativum L. (Family Umbelliferae)."
},
{
"name": "Constituents",
"text": "Coriander Oil contains predominantly monoterpene alcohols as linalool. It also contains terpenes (e.g., α -pinene, limonene, γ -terpinene), and camphor."
},
{
"name": "Description",
"text": "Clear colourless or pale yellow liquid odourless."
},
{
"name": "Solubility",
"text": "test Soluble, at 2 0° in 3 volumes of ethanol (70 per cent)."
},
{
"name": "Packaging and storage",
"text": "Coriander Oil shall be kept in well-filled, tightly closed containers, protected from light, and stored at a temperature not exceeding 25° ."
},
{
"name": "Identification",
"text": "Carry out the test as described in the \"Thin-Layer Chromatography\" (Appendix 3.1).\nStandard solution Dissolve 10 μL of linalool, and 2 μL of geranyl acetate in 1.0 mL of toluene.\nTest solution Dissolve 10 μL in toluene and dilute to 1.0 mL with the same solvent.\nAdsorbent Silica gel F254 (TLC or HPLC plate). Mobile phase Ethyl acetate and toluene (5:95).\nApplication Apply 10 μL (or 2 μL ) each of Standard solution and Test solution as 15-mm (or 8-mm) bands.\nDevelopment and drying Allow the solvent front to ascend 10 cm (or 6 cm) above the line of application.\nDry the developed plate in air for 5 minutes.\nResults When examined under visible light, the test solution shows a violet band due to linalool in the lower third, corresponding in colour and R_{f} to the band shown by the standard solution. A violet-blue band near the starting line and a bluish violet band in the upper third of the chromatogram is present.\nDetection Spray the plate with anisaldehyde TS, heat at 105° for 5 minutes and examine under visible light Observe the result.\nThe retention time of the major peaks in the chromatogram of the Coriander Oil correspond to those in the chromatogram of the Standard solution (a), as obtained in the Chromatographic profile. Specific gravity 0.860 to 0.880 (Appendix 4.9). Optical rotation + 7° to + 13° (Appendix 4.8). Refractive index 1.462 to 1.470, at 20° (Appendix 4.7). Acid value Not more than 3.0; use 5 g (Appendix 5.4) Chromatographic profile Carry out the test as described in the \"Gas Chromatography\" (Appendix 3.4)\nStandard solution (a) Dissolve 10 μL of a-pinene, 10 μL of limonene, 10 μL of γ -terpinene, 10 μL of p-cymene, 10 mg of camphor, 20 μL of linalool, 10 μL of a-terpineol, 10 μL of geranyl acetate and 10 μL of geraniol in 1 mL of heptane.\nStandard solution (b) Dissolve 5 μL of geraniol in heptane and dilute to 10.0 mL with the same solvent. Test solution Use Coriander oil. Chromatographic system DETECTOR Flame ionization COLUMN A fused-silica capillary column (60 m \\times 0.25 mm) packed with macrogol 20000 (0.25 μm ). TEMPERATURE Column The temperature programme is as follows:\n<table border=\"1\"><tr><td>Time(Minutes)</td><td>Temperature(°)</td></tr><tr><td>0-10</td><td>60</td></tr><tr><td>10-75</td><td>60→190</td></tr><tr><td>75-120</td><td>190</td></tr></table>\nInjection port 220° Detector 240° CARRIER GAS Helium SPLIT RATIO 1:65 FLOW RATE 1 mL per minute System suitability SAMPLE Standard solution (a) Suitability requirements\nRESOLUTION Not less than 1.5 between linalool and camphor peaks.\nProcedure Inject a portion (about 0.2 mL) of Standard\nsolution (a), Standard solution (b) and Test solution into the chromatograph. Identify the peaks due to the components in Coriander Oil, using the retention times determined from the chromatogram obtained from the standard solution (a). Measure the areas of the principal peaks in the chromatogram obtained from the Coriander Oil.\nCalculation Calculate the percentage content of the components of Coriander Oil taken by normalization procedure."
},
{
"name": "Limits",
"text": "- a-pinene: 3.0 per cent to 7.0 per cent.\n- limonene: 1.5 per cent to 5.0 per cent.\n- γ -terpinene: 1.5 per cent to 8.0 per cent.\n- p-cymene: 0.5 per cent to 4.0 per cent.\n- camphor: 3.0 per cent to 6.0 per cent.\n- linalool: 65.0 per cent to 78.0 per cent.\n- a-terpineol: 0.1 per cent to 1.5 per cent.\n- geranyl acetate: 0.5 per cent to 4.0 per cent.\n- geraniol: 0.5 per cent to 3.0 per cent.\n- disregard limit: area of the peak in the\nchromatogram obtained from the standard solution (b) (0.05 per cent).\nChiral purity Not more than 14 per cent of (R)-linalool. Carry out the test as described in the \"Gas\nChromatography\" (Appendix 3.4).\nStandard solution Dissolve 10 μL of linalool and 5 mg of borueol in pentane and dilute to 10.0 mL with the same solvent.\nTest solution Dissolve 20 mg of Coriander Oil in pentane and dilute to 10.0 mL with the same solvent.\nChromatographic system\nDETECTOR Flame ionization\nCOLUMN A fused-silica capillary column (25 m \\times 0.25 mm) packed with modified b-cyclodextrin for chiral chromatography (0.25 \\mum).\nTEMPERATURE\nColumn The temperature programme is as follows:\n<table border=\"1\"><tr><td>Time(Minutes)</td><td colspan=\"2\">Temperature(°)</td></tr><tr><td>0-65</td><td colspan=\"2\">50→180</td></tr><tr><td colspan=\"3\">Injection port230°Detector230°CARRIER GASHeliumSPLIT RATIO1:30FLOW RATE1.3mL per minute</td></tr><tr><td colspan=\"3\">System suitabilitySAMPLEStandard solution</td></tr><tr><td colspan=\"3\">Suitability requirementsRESOLUTIONNot less than5.5between(R)-linalo first peak)and(S)-linalool(second peak)and not less than2.9between the peaks due to(S)-linalool and</td></tr></table>\nborneol (third peak).\nProcedure Separately inject equal volumes (about 1 μL ) of Standard solution and Test solution into the chromatograph. Measure the responses for the major peaks.\nCalculation Calculate the percentage content of (R)-linalool using the expression:\n\\frac {A _ {R}}{A _ {S} + A _ {R}} \\times 1 0 0 \\mathrm{A_{S}} = area of the peak due to (S)- linalool; A_{R} area of the peak due to (R)- linalool."
}
]
}