Determination Of Arsenic, Cadmium And Lead Using Aas With Cold-vapour Or Hydride Atomization
Definition
Carry out the test as described by the "Atomic Spectrometry: Emission and Absorption" (Appendix 2.3) and measure the content of arsenic and mercury by the "Method of Direct Calibration" (Method I, Appendix 2.3) or by the "Method of Standard Additions" (Method II, Appendix 2.3), using standard solutions of arsenic or mercury and an automated continuous-flow hydride vapour generation system. The absorbance value of the blank solution is subtracted from the value obtained with the test solution. ## ARSENIC Sample solution To 19.0 mL of the test solution or of the blank solution as prescribed above, add 1 mL of a 20 per cent w/v solution of potassium iodide. Allow the test solution to stand at room temperature for about 50 minutes or at $ 7 0^{\circ} $ for about 4 minutes. Acid reagent Use Heavy metal-free hydrochloric acid. Reducing reagent Prepare a 0.6 per cent w/v solution of sodium tetrahydroborate in a 0.5 per cent w/v solution of sodium hydroxide. The recommended instrumental parameters in Table 2 may be used. ## MERCURY Sample solution Use Test solution or Blank solution, as prescribed above. Acid reagent Prepare a 51.5 per cent w/v solution of heavy metal-free hydrochloric acid. Reducing reagent Prepare a 1.0 per cent w/v solution of stannous chloride in heavy metal-free dilute hydrochloric acid. The recommended instrumental parameters in Table 2 may be used. Table 2 Instrumental Parameters for AAS with Cold-Vapour or Hydride Atomization <table border="1"><tr><td></td><td></td><td>As</td><td>Hg</td></tr><tr><td>Wavelength</td><td>nm</td><td>193.7</td><td>253.7</td></tr><tr><td>Slit width</td><td>nm</td><td>0.2</td><td>0.5</td></tr><tr><td>Lamp current</td><td>mA</td><td>10</td><td>4</td></tr><tr><td>Acid reagent flow rate</td><td>mL/min</td><td>1.0</td><td>1.0</td></tr><tr><td>Reducing reagent flow rate</td><td>mL/min</td><td>1.0</td><td>1.0</td></tr><tr><td>Sample solution flow rate</td><td>mL/min</td><td>7.0</td><td>7.0</td></tr><tr><td>Absorption cell</td><td></td><td>Quartz(heated)</td><td>Quartz(unheated)</td></tr><tr><td>Nitrogen flow rate</td><td>L/min</td><td>0.1</td><td>0.1</td></tr></table> ## Determination of Arsenic, Cadmium, Mercury, and Lead Using ICP-AES Carry out the test as described by the "ICP-AES" (Appendix 2.10) and measure the content of arsenic, cadmium, mercury, and lead by the "Method of Direct Calibration" (Method I, Appendix 2.3), using standard solutions of each heavy metal or a mixture of all measured metals, and the instrumental parameters recommended in Table 3. The emission value of the blank solution is subtracted from the value obtained with the test solution. Table 3 Instrumental Parameters for ICP-AES <table border="1"><tr><td></td><td></td><td>As</td><td>Cd</td><td>Hg</td><td>Pb</td></tr><tr><td rowspan="3">Wavelength</td><td rowspan="3">nm</td><td>193.696/</td><td>214.438/</td><td>184.950/</td><td>220.351/</td></tr><tr><td>197.197/</td><td>226.502/</td><td>253.652/</td><td>283.306/</td></tr><tr><td>189.042</td><td>228.802</td><td>435.835</td><td>168.215</td></tr><tr><td>Ar, Monitorline</td><td>nm</td><td>430.010</td><td>430.010</td><td>430.010</td><td>430.010</td></tr><tr><td>Plasma energy</td><td>W</td><td>1200</td><td>1200</td><td>1200</td><td>1200</td></tr><tr><td>Peak algorithm with background correction</td><td></td><td>yes</td><td>yes</td><td>yes</td><td>yes</td></tr></table> ## Determination of Arsenic, Cadmium, Mercury, and Lead Using ICP-MS Carry out the test as described by the "ICP-MS" (Appendix 2.10) and measure the content of arsenic, cadmium, mercury, and lead by the "Method of Direct Calibration" (Method I, Appendix 2.3) using standard solutions of each heavy metal and the analytical isotopes and additional masses recommended in Table 4. The signal intensity of the blank solution is subtracted from the value obtained with the test solution. ## System Suitability A system suitability test must be carried out on the day of the analysis to en
Monograph text
Full text
Carry out the test as described by the "Atomic Spectrometry: Emission and Absorption" (Appendix 2.3) and measure the content of arsenic and mercury by the "Method of Direct Calibration" (Method I, Appendix 2.3) or by the "Method of Standard Additions" (Method II, Appendix 2.3), using standard solutions of arsenic or mercury and an automated continuous-flow hydride vapour generation system. The absorbance value of the blank solution is subtracted from the value obtained with the test solution. ## ARSENIC Sample solution To 19.0 mL of the test solution or of the blank solution as prescribed above, add 1 mL of a 20 per cent w/v solution of potassium iodide. Allow the test solution to stand at room temperature for about 50 minutes or at 7 0° for about 4 minutes. Acid reagent Use Heavy metal-free hydrochloric acid. Reducing reagent Prepare a 0.6 per cent w/v solution of sodium tetrahydroborate in a 0.5 per cent w/v solution of sodium hydroxide. The recommended instrumental parameters in Table 2 may be used. ## MERCURY Sample solution Use Test solution or Blank solution, as prescribed above. Acid reagent Prepare a 51.5 per cent w/v solution of heavy metal-free hydrochloric acid. Reducing reagent Prepare a 1.0 per cent w/v solution of stannous chloride in heavy metal-free dilute hydrochloric acid. The recommended instrumental parameters in Table 2 may be used. Table 2 Instrumental Parameters for AAS with Cold-Vapour or Hydride Atomization <table border="1"><tr><td></td><td></td><td>As</td><td>Hg</td></tr><tr><td>Wavelength</td><td>nm</td><td>193.7</td><td>253.7</td></tr><tr><td>Slit width</td><td>nm</td><td>0.2</td><td>0.5</td></tr><tr><td>Lamp current</td><td>mA</td><td>10</td><td>4</td></tr><tr><td>Acid reagent flow rate</td><td>mL/min</td><td>1.0</td><td>1.0</td></tr><tr><td>Reducing reagent flow rate</td><td>mL/min</td><td>1.0</td><td>1.0</td></tr><tr><td>Sample solution flow rate</td><td>mL/min</td><td>7.0</td><td>7.0</td></tr><tr><td>Absorption cell</td><td></td><td>Quartz(heated)</td><td>Quartz(unheated)</td></tr><tr><td>Nitrogen flow rate</td><td>L/min</td><td>0.1</td><td>0.1</td></tr></table> ## Determination of Arsenic, Cadmium, Mercury, and Lead Using ICP-AES Carry out the test as described by the "ICP-AES" (Appendix 2.10) and measure the content of arsenic, cadmium, mercury, and lead by the "Method of Direct Calibration" (Method I, Appendix 2.3), using standard solutions of each heavy metal or a mixture of all measured metals, and the instrumental parameters recommended in Table 3. The emission value of the blank solution is subtracted from the value obtained with the test solution. Table 3 Instrumental Parameters for ICP-AES <table border="1"><tr><td></td><td></td><td>As</td><td>Cd</td><td>Hg</td><td>Pb</td></tr><tr><td rowspan="3">Wavelength</td><td rowspan="3">nm</td><td>193.696/</td><td>214.438/</td><td>184.950/</td><td>220.351/</td></tr><tr><td>197.197/</td><td>226.502/</td><td>253.652/</td><td>283.306/</td></tr><tr><td>189.042</td><td>228.802</td><td>435.835</td><td>168.215</td></tr><tr><td>Ar, Monitorline</td><td>nm</td><td>430.010</td><td>430.010</td><td>430.010</td><td>430.010</td></tr><tr><td>Plasma energy</td><td>W</td><td>1200</td><td>1200</td><td>1200</td><td>1200</td></tr><tr><td>Peak algorithm with background correction</td><td></td><td>yes</td><td>yes</td><td>yes</td><td>yes</td></tr></table> ## Determination of Arsenic, Cadmium, Mercury, and Lead Using ICP-MS Carry out the test as described by the "ICP-MS" (Appendix 2.10) and measure the content of arsenic, cadmium, mercury, and lead by the "Method of Direct Calibration" (Method I, Appendix 2.3) using standard solutions of each heavy metal and the analytical isotopes and additional masses recommended in Table 4. The signal intensity of the blank solution is subtracted from the value obtained with the test solution. ## System Suitability A system suitability test must be carried out on the day of the analysis to ensure that the sample preparation and measurement system are appropriate. ## Acceptance criterion for preparation of sample solution A clear solution is obtained. Acceptance criterion for measurement system The measured concentration of a standard solution of the metal at a concentration within the range of the used calibration curve does not differ from the actual concentration by more than 20 per cent. Table 4 Recommended Analytical Isotopes and Additional Masses for ICP-MS <table border="1"><tr><td>Isotope</td><td>Element of Interest</td></tr><tr><td>75</td><td>Arsenic</td></tr><tr><td>106,108,111,114</td><td>Cadmium</td></tr><tr><td>202</td><td>Mercury</td></tr><tr><td>206,207,208</td><td>Lead</td></tr></table> ## Validation Requirements The analytical procedures used must be validated in accordance with the relevant general methods as described in the "Atomic Spectrometry: Emission and Absorption" (Appendix 2.3), "ICP-AES" (Appendix 2.10) and "ICP-MS" (Appendix 2.10). Additionally, the following criteria must be fulfilled. ## Specificity Specificity is the ability to ensure that the analytical procedures for sample preparation and measurement allow a reliable determination of the metal(s) in the presence of components (e.g., carrier gas, impurities, matrix) that may be expected to be present. Acceptance criteria The procedure must be able to assess unequivocally each heavy metal to be determined with this procedure in the presence of components that may be expected to be present, including other heavy metals, matrix components and other sources of interference; specificity is demonstrated by complying with the accuracy requirement for the metal(s) to be determined. ## Range The calibration range of each metal is within the linear range of the method; test solutions containing residues at a level outside the calibration range may be diluted to concentrations within the calibration range. Acceptance criterion Range is demonstrated by complying with the recove
No counterparts indexed yet — search this title across all datasets
View raw JSON-LD
{
"@id": "https://www.openphar.org/data/thp/appendices/determination-of-arsenic-cadmium-and-lead-using-aas-with-cold-vapour-or-hydride-",
"@type": "IndexedMonograph",
"prefLabel": {
"en": "Determination Of Arsenic, Cadmium And Lead Using Aas With Cold-vapour Or Hydride Atomization"
},
"edition": "THP-2020-Vol-II",
"category": "appendices",
"definition": {
"en": "Carry out the test as described by the \"Atomic Spectrometry: Emission and Absorption\" (Appendix 2.3) and measure the content of arsenic and mercury by the \"Method of Direct Calibration\" (Method I, Appendix 2.3) or by the \"Method of Standard Additions\" (Method II, Appendix 2.3), using standard solutions of arsenic or mercury and an automated continuous-flow hydride vapour generation system.\n\nThe absorbance value of the blank solution is subtracted from the value obtained with the test solution.\n\n## ARSENIC\n\nSample solution To 19.0 mL of the test solution or of the blank solution as prescribed above, add 1 mL of a 20 per cent w/v solution of potassium iodide. Allow the test solution to stand at room temperature for about 50 minutes or at $ 7 0^{\\circ} $ for about 4 minutes.\n\nAcid reagent Use Heavy metal-free hydrochloric acid.\n\nReducing reagent Prepare a 0.6 per cent w/v solution of sodium tetrahydroborate in a 0.5 per cent w/v solution of sodium hydroxide.\n\nThe recommended instrumental parameters in Table 2 may be used.\n\n## MERCURY\n\nSample solution Use Test solution or Blank solution, as prescribed above.\n\nAcid reagent Prepare a 51.5 per cent w/v solution of heavy metal-free hydrochloric acid.\n\nReducing reagent Prepare a 1.0 per cent w/v solution of stannous chloride in heavy metal-free dilute hydrochloric acid.\n\nThe recommended instrumental parameters in Table 2 may be used.\n\n\n\nTable 2 Instrumental Parameters for AAS with Cold-Vapour or Hydride Atomization\n\n\n\n<table border=\"1\"><tr><td></td><td></td><td>As</td><td>Hg</td></tr><tr><td>Wavelength</td><td>nm</td><td>193.7</td><td>253.7</td></tr><tr><td>Slit width</td><td>nm</td><td>0.2</td><td>0.5</td></tr><tr><td>Lamp current</td><td>mA</td><td>10</td><td>4</td></tr><tr><td>Acid reagent flow rate</td><td>mL/min</td><td>1.0</td><td>1.0</td></tr><tr><td>Reducing reagent flow rate</td><td>mL/min</td><td>1.0</td><td>1.0</td></tr><tr><td>Sample solution flow rate</td><td>mL/min</td><td>7.0</td><td>7.0</td></tr><tr><td>Absorption cell</td><td></td><td>Quartz(heated)</td><td>Quartz(unheated)</td></tr><tr><td>Nitrogen flow rate</td><td>L/min</td><td>0.1</td><td>0.1</td></tr></table>\n\n## Determination of Arsenic, Cadmium, Mercury, and Lead Using ICP-AES\n\nCarry out the test as described by the \"ICP-AES\" (Appendix 2.10) and measure the content of arsenic, cadmium, mercury, and lead by the \"Method of Direct Calibration\" (Method I, Appendix 2.3), using standard solutions of each heavy metal or a mixture of all measured metals, and the instrumental parameters recommended in Table 3.\n\nThe emission value of the blank solution is subtracted from the value obtained with the test solution.\n\n\n\nTable 3 Instrumental Parameters for ICP-AES\n\n\n\n<table border=\"1\"><tr><td></td><td></td><td>As</td><td>Cd</td><td>Hg</td><td>Pb</td></tr><tr><td rowspan=\"3\">Wavelength</td><td rowspan=\"3\">nm</td><td>193.696/</td><td>214.438/</td><td>184.950/</td><td>220.351/</td></tr><tr><td>197.197/</td><td>226.502/</td><td>253.652/</td><td>283.306/</td></tr><tr><td>189.042</td><td>228.802</td><td>435.835</td><td>168.215</td></tr><tr><td>Ar, Monitorline</td><td>nm</td><td>430.010</td><td>430.010</td><td>430.010</td><td>430.010</td></tr><tr><td>Plasma energy</td><td>W</td><td>1200</td><td>1200</td><td>1200</td><td>1200</td></tr><tr><td>Peak algorithm with background correction</td><td></td><td>yes</td><td>yes</td><td>yes</td><td>yes</td></tr></table>\n\n## Determination of Arsenic, Cadmium, Mercury, and Lead Using ICP-MS\n\nCarry out the test as described by the \"ICP-MS\" (Appendix 2.10) and measure the content of arsenic, cadmium, mercury, and lead by the \"Method of Direct Calibration\" (Method I, Appendix 2.3) using standard solutions of each heavy metal and the analytical isotopes and additional masses recommended in Table 4.\n\nThe signal intensity of the blank solution is subtracted from the value obtained with the test solution.\n\n## System Suitability\n\nA system suitability test must be carried out on the day of the analysis to en"
},
"sections": [
{
"name": "Full text",
"text": "Carry out the test as described by the \"Atomic Spectrometry: Emission and Absorption\" (Appendix 2.3) and measure the content of arsenic and mercury by the \"Method of Direct Calibration\" (Method I, Appendix 2.3) or by the \"Method of Standard Additions\" (Method II, Appendix 2.3), using standard solutions of arsenic or mercury and an automated continuous-flow hydride vapour generation system.\n\nThe absorbance value of the blank solution is subtracted from the value obtained with the test solution.\n\n## ARSENIC\n\nSample solution To 19.0 mL of the test solution or of the blank solution as prescribed above, add 1 mL of a 20 per cent w/v solution of potassium iodide. Allow the test solution to stand at room temperature for about 50 minutes or at 7 0° for about 4 minutes.\n\nAcid reagent Use Heavy metal-free hydrochloric acid.\n\nReducing reagent Prepare a 0.6 per cent w/v solution of sodium tetrahydroborate in a 0.5 per cent w/v solution of sodium hydroxide.\n\nThe recommended instrumental parameters in Table 2 may be used.\n\n## MERCURY\n\nSample solution Use Test solution or Blank solution, as prescribed above.\n\nAcid reagent Prepare a 51.5 per cent w/v solution of heavy metal-free hydrochloric acid.\n\nReducing reagent Prepare a 1.0 per cent w/v solution of stannous chloride in heavy metal-free dilute hydrochloric acid.\n\nThe recommended instrumental parameters in Table 2 may be used.\n\n\n\nTable 2 Instrumental Parameters for AAS with Cold-Vapour or Hydride Atomization\n\n\n\n<table border=\"1\"><tr><td></td><td></td><td>As</td><td>Hg</td></tr><tr><td>Wavelength</td><td>nm</td><td>193.7</td><td>253.7</td></tr><tr><td>Slit width</td><td>nm</td><td>0.2</td><td>0.5</td></tr><tr><td>Lamp current</td><td>mA</td><td>10</td><td>4</td></tr><tr><td>Acid reagent flow rate</td><td>mL/min</td><td>1.0</td><td>1.0</td></tr><tr><td>Reducing reagent flow rate</td><td>mL/min</td><td>1.0</td><td>1.0</td></tr><tr><td>Sample solution flow rate</td><td>mL/min</td><td>7.0</td><td>7.0</td></tr><tr><td>Absorption cell</td><td></td><td>Quartz(heated)</td><td>Quartz(unheated)</td></tr><tr><td>Nitrogen flow rate</td><td>L/min</td><td>0.1</td><td>0.1</td></tr></table>\n\n## Determination of Arsenic, Cadmium, Mercury, and Lead Using ICP-AES\n\nCarry out the test as described by the \"ICP-AES\" (Appendix 2.10) and measure the content of arsenic, cadmium, mercury, and lead by the \"Method of Direct Calibration\" (Method I, Appendix 2.3), using standard solutions of each heavy metal or a mixture of all measured metals, and the instrumental parameters recommended in Table 3.\n\nThe emission value of the blank solution is subtracted from the value obtained with the test solution.\n\n\n\nTable 3 Instrumental Parameters for ICP-AES\n\n\n\n<table border=\"1\"><tr><td></td><td></td><td>As</td><td>Cd</td><td>Hg</td><td>Pb</td></tr><tr><td rowspan=\"3\">Wavelength</td><td rowspan=\"3\">nm</td><td>193.696/</td><td>214.438/</td><td>184.950/</td><td>220.351/</td></tr><tr><td>197.197/</td><td>226.502/</td><td>253.652/</td><td>283.306/</td></tr><tr><td>189.042</td><td>228.802</td><td>435.835</td><td>168.215</td></tr><tr><td>Ar, Monitorline</td><td>nm</td><td>430.010</td><td>430.010</td><td>430.010</td><td>430.010</td></tr><tr><td>Plasma energy</td><td>W</td><td>1200</td><td>1200</td><td>1200</td><td>1200</td></tr><tr><td>Peak algorithm with background correction</td><td></td><td>yes</td><td>yes</td><td>yes</td><td>yes</td></tr></table>\n\n## Determination of Arsenic, Cadmium, Mercury, and Lead Using ICP-MS\n\nCarry out the test as described by the \"ICP-MS\" (Appendix 2.10) and measure the content of arsenic, cadmium, mercury, and lead by the \"Method of Direct Calibration\" (Method I, Appendix 2.3) using standard solutions of each heavy metal and the analytical isotopes and additional masses recommended in Table 4.\n\nThe signal intensity of the blank solution is subtracted from the value obtained with the test solution.\n\n## System Suitability\n\nA system suitability test must be carried out on the day of the analysis to ensure that the sample preparation and measurement system are appropriate.\n\n## Acceptance criterion for preparation of sample solution A clear solution is obtained.\n\nAcceptance criterion for measurement system The measured concentration of a standard solution of the metal at a concentration within the range of the used calibration curve does not differ from the actual concentration by more than 20 per cent.\n\n\n\nTable 4 Recommended Analytical Isotopes and Additional Masses for ICP-MS\n\n\n\n<table border=\"1\"><tr><td>Isotope</td><td>Element of Interest</td></tr><tr><td>75</td><td>Arsenic</td></tr><tr><td>106,108,111,114</td><td>Cadmium</td></tr><tr><td>202</td><td>Mercury</td></tr><tr><td>206,207,208</td><td>Lead</td></tr></table>\n\n## Validation Requirements\n\nThe analytical procedures used must be validated in accordance with the relevant general methods as described in the \"Atomic Spectrometry: Emission and Absorption\" (Appendix 2.3), \"ICP-AES\" (Appendix 2.10) and \"ICP-MS\" (Appendix 2.10). Additionally, the following criteria must be fulfilled.\n\n## Specificity\n\nSpecificity is the ability to ensure that the analytical procedures for sample preparation and measurement allow a reliable determination of the metal(s) in the presence of components (e.g., carrier gas, impurities, matrix) that may be expected to be present.\n\nAcceptance criteria The procedure must be able to assess unequivocally each heavy metal to be determined with this procedure in the presence of components that may be expected to be present, including other heavy metals, matrix components and other sources of interference; specificity is demonstrated by complying with the accuracy requirement for the metal(s) to be determined.\n\n## Range\n\nThe calibration range of each metal is within the linear range of the method; test solutions containing residues at a level outside the calibration range may be diluted to concentrations within the calibration range.\n\nAcceptance criterion Range is demonstrated by complying with the recove"
}
]
}