Determination of diethylene glycol and ethylene glycol in liquid preparations for oral use
10.5.2
Definition
2025-02
Monograph text
opening
2025-02
Introduction and scope
Introduction and scope Diethylene glycol (DEG) and ethylene glycol (EG) are toxic substances commonly used as industrial solvents and antifreeze agents. Even small quantities can be fatal, particularly for children. Over the past decades, numerous incidents of medicine contamination with EG and DEG have been reported. These cases involved liquid preparations for oral use manufactured with excipients such as glycerol and propylene glycol that were contaminated, adulterated or mistakenly substituted with DEG or EG. Such incidents have resulted in hundreds of deaths worldwide, often through kidney failure. Although no definitive safe levels for human ingestion have been established, a detection threshold of 0.10 % for each substance is generally considered acceptable in raw materials and finished pharmaceutical products from a safety perspective. Gas chromatography with a flame ionization detector (GC-FID) is a reliable and widely used analytical technique for the accurate and precise detection of volatile substances. It has frequently been applied for the determination of DEG and EG in pharmaceutical excipients and formulations. Other analytical techniques described in the literature include High-performance thin-layer chromatography (HPTLC) [1], Ultrahigh-performance supercritical fluid chromatography - Mass spectrometry after precolumn derivatization [2] and Gas chromatography - Tandem mass spectrometry [3]. The following text describes an HPTLC and a GC-FID method for the determination of DEG and EG in liquid preparations for oral use. National Quality Control Laboratories should be prepared to test samples from their markets for DEG and EG to safeguard patients from contaminated products. The selection of the analytical method should be based on the availability of suitable equipment and the training and expertise of laboratory personnel. The HPTLC method may thereby be particularly suitable for less-resourced laboratories. The described HPTLC procedure is presented as a semiquantitative limit test, involving several manual operations and a visual comparison of band intensities. The sensitivity and precision of the method depend both on the analyst’s expertise and training and the performance of the equipment used. However, the procedure can also be implemented as a fully quantitative method, for example using automatic sample application and densitometric evaluation of chromatograms. Depending on whether it is implemented as a semiquantitative or quantitative method, the procedure may serve either as a screening tool for detecting non-compliance (to be followed by a confirmatory test) or as a complementary technique to corroborate results obtained with other quantitative procedure, such as the described GC method. Laboratories that confirm the presence of DEG or EG contamination in excipients or finished products should notify the relevant regulatory authorities without delay.
Determination by High-performance thin-layer chromatography (HPTLC)
Determination by High-performance thin-layer chromatography (HPTLC) Note. EG and DEG exhibit similar RF values in the described HPTLC procedure. Reference solutions containing 50:50 (m/m) mixtures of DEG and EG are used to calibrate the analyte response. As a result, analysts determine the combined concentration of DEG and EG rather than quantifying each contaminant individually.
Procedure
Procedure. Carry out the test as described under 1.18 High-Performance Thin-layer chromatography, using an HPTLC silica gel 60 F254 plate (2-10 µm) as the stationary phase. Prepare the following solutions: Developing solvent system. A freshly prepared mixture of water R, concentrated ammonia solution R, toluene R and acetone R (9.5:1:5:85 V/V/V/V). Add the solvents in the described order and mix. Derivatization reagent. Prepare a mixture of 0.75 g of potassium permanganate R, 5 g of sodium carbonate R and 0.625 mL of sodium hydroxide (~ 100 g/L) TS in 100 mL of water R. Stock solutions For solution (H1) (EG+DEG stock solution, 20% (m/m) with reference to the sample concentration in solutions S10, 10 mg EG + 10 mg DEG per mL), dissolve 500 mg of diethylene glycol RS and 500 mg of ethylene glycol RS in 50.0 mL of methanol R. For solution (H2) (EG+DEG stock solution, 2% (m/m) with reference to the sample concentration in solutions S10, 1 mg EG + 1 mg DEG per mL), dilute 10.0 mL of solution (H1) to 100.0 mL with methanol R. For solution (H3) (PG/Glycerol stock solution), transfer 5.0 g of propylene glycol R and 5.0 g of glycerol R to a 500 mL volumetric flask, add 400 mL of methanol R, sonicate for 5 minutes and make up to volume with the same solvent. Sample solution For solution (S10) (sample solution, 100 mg sample per mL), transfer 1.000 g of the liquid preparation for oral use under investigation to a 10.0 mL volumetric flask. Add 5 mL of methanol R, stopper the flask and shake vigorously. Make up to volume with methanol R, mix thoroughly and filtrate, if necessary. For solution (S11) (EG and DEG spiked sample solution, 1.0 % (m/m)), transfer 1.000 g of the liquid preparation for oral use under investigation to a 10.0 mL volumetric flask. Add 1.0 mL of solution (R0) and 4 mL of methanol R, stopper the flask and shake vigorously. Make up to volume with methanol R, mix thoroughly and filtrate, if necessary. Reference solution containing EG and DEG For solution (R0) (EG+DEG reference solution, 10% (m/m) with reference to the sample concentration in solution (S10), 5 mg EG + 5 mg DEG per mL), transfer 10.0 mL of solution (H1) to a 20 mL volumetric flask and dilute to volume with methanol R. For solution (R1) (EG+DEG reference solution, 5% (m/m) with reference to the sample concentration in solution (S10), 2.5 mg EG + 2.5 mg DEG per mL), transfer 5.0 mL of solution (H1) to a 20 mL volumetric flask, add 5.0 mL of solution (H3) and dilute to volume with methanol R. For solution (R2) (EG+DEG reference solution, 1% (m/m) with reference to the sample concentration in solution (S10), 0.5 mg EG + 0.5 mg DEG per mL), transfer 5.0 mL of solution (H1) to a 100 mL volumetric flask, add 25.0 mL of solution (H3) and dilute to volume with methanol R. For solution (R3) (EG+DEG reference solution, 0.2% (m/m) with reference to the sample concentration in solution (S10), 0.1 mg EG + 0.1 mg DEG per mL), transfer 10.0 mL of solution (H2) to a 100 mL volumetric flask, add 25.0 mL of solution (H3) and dilute to volume with methanol R. For solution (R4) (EG+DEG reference solution, 0.1% (m/m) with reference to the sample concentration in solution (S10), 0.05 mg EG + 0.05 mg DEG per mL), transfer 5.0 mL of solution (H2) to a 100 mL volumetric flask, add 25.0 mL of solution (H3) and dilute to volume with methanol R. For solution (R5) (EG+DEG reference solution, 0.05% (m/m) with reference to the sample concentration in solution (S10), 0.025 mg EG + 0.025 mg DEG per mL), transfer 2.5 mL of solution (H2) to a 100 mL volumetric flask, add 25.0 mL of solution (H3) and dilute to volume with methanol R. Analysis. Apply 5 µL of each of solutions (S10), (S11), (R1), (R2), (R3), (R4) and (R5) as bands and dry them in air. Precondition the plate to control its activity and develop it in a saturated chamber. Remove the plate, dry it in a stream of air at room temperature and examine it under white light, short-wave and long-wave UV light. Use a pencil to lightly circle the spots that are visible in daylight and under UV light. The substances identified may originate from active ingredients, their impurities or degradants, excipients, or other matrix components. To identify the spots due to EG/DEG, propylene glycol, glycerol and other components of the sample that are not visible in daylight and under UV light, spray the plate with the derivatization reagent and dry it in a stream of warm air for about 15 to 20 minutes. Let the plate rest for 5 minutes. Examine the plate under white light. Bright yellow spots should be visible. The following substances are eluted with the following RF values: sorbitol, if present, about 0.08; glycerol about 0.37; DEG and EG about 0.53; propylene glycol about 0.61. Determine if components of the sample interfere with the EG/DEG determination by comparing the RF values of spots circled in daylight or UV light with the RF value of the spot due to EG/DEG after derivatization. The test is not valid unless the chromatograms obtained with solutions (R1), (R2), and (R3) show three resolved spots due to propylene glycol, EG / DEG and glycerol and in the chromatogram obtained with solution (S11) the spot due to EG or DEG is free of interferences. Determine whether a spot due to EG/DEG is present in the chromatogram obtained with solution (S10). If present, estimate the approximate percentage content of DEG or EG (m/m) in the liquid preparation for oral use under investigation by comparing the intensity of the spot due to EG or DEG in the chromatogram obtained with solution (S10) with the intensities of the spots due to EG/DEG in the chromatograms obtained with solutions (R1) to (R5).
Determination by gas chromatography with flame-ionization detection (GC-FID)
Determination by gas chromatography with flame-ionization detection (GC-FID) Carry out the test as described under 1.14.1 Chromatography, Gas chromatography using the internal standard method. For the procedure, use a capillary glass or quartz column (30 m × 0.53 mm), the inner surface of which is coated with a layer of macrogol 20M R (1.0 μm). Maintain the temperature of the column at 100 °C for 5 minutes. Increase the temperature at a rate of 10 °C per minute to 245 °C and maintain it at this point for 4 minutes. Maintain the temperature of the injection port and the detector at 250 °C. Use helium R or nitrogen R as the carrier gas with a linear velocity of about 38 cm per second. Use split injection ratio of 1:20 and a flame-ionization detector for detection. The retention times and the separation of peaks are similar when using helium R or nitrogen R as the carrier gas. Although the peaks are slightly sharper when using helium R, the use of nitrogen R is preferable from a sustainability perspective. Laboratories that can only obtain a column with a maximum temperature of 240 °C or below may change the temperature accordingly, if necessary. However, lowering the temperature may affect the ability of the method to clean the column of substances with a high boiling point thus deteriorating column performance over time. The described procedure was validated using helium as a carrier gas. The use of nitrogen or hydrogen may also be suitable with little or no changes in peak resolution. Helium is a non-renewable gas that may be or eventually become difficult to source. Nitrogen and hydrogen can be produced on-demand using suitable generators. For solution (IS) (10 mg IS per mL), weigh 0.500 g of the internal standard 1,3-butanediol R and dilute to 50.0 mL with water R. During the elaboration of the analytical procedure, it was noted that the peak due to 1,3-butanediol may show peak tailing when columns with thinner layers of macrogol are used. In such cases, 1,3 propanediol R was found to be a suitable alternative to 1,3-butanediol R. For solution (A) (sample solution, 25 mg of sample per mL), weigh 0.500 g of the liquid preparation for oral use under investigation into a 20 mL volumetric flask, add 1.0 mL of solution (IS) and 1.0 mL of water R and mix thoroughly. Make up to volume with ethanol R and sonicate for 5 minutes. Place the solution in an ice bath for 15 minutes and filter. For solution (B) (sample solution without IS), weigh 0.500 g of the liquid preparation for oral solution under investigation into a 20 mL volumetric flask, add 2.0 mL of water R and mix thoroughly. Make up to volume with ethanol R and sonicate for 5 minutes. Place the solution in an ice bath for 15 minutes and filter. For solution (C) (EG, PG, DEG stock solution; 10 mg each per mL), weigh 1.000 g of each ethylene glycol RS, propylene glycol R and diethylene glycol RS and dilute to 100.0 mL with ethanol R. For solution (D) (EG, PG, DEG stock solution; 1.0 mg each per mL), dilute 2.0 mL of solution (C) to 20.0 mL with ethanol R. For solution (E) (EG, DEG calibration solution, 1.25 mg each per mL, 5% with regards to sample concentration in solution (A)), mix 25.0 mL of solution (C) with 10.0 mL of solution (IS), 15 mL of water R and dilute to 200.0 mL with ethanol R. For solution (F) (EG, DEG calibration solution, 0.5 mg each per mL, 2% with regards to sample concentration in solution (A)), mix 1.0 mL of solution (C) with 1.0 mL of solution (IS), 1.5 mL of water R and dilute to 20.0 mL with ethanol R. For solution (G) (EG, DEG calibration solution, 0.1 mg each per mL, 0.4% with regards to sample concentration in solution (A)), mix 2.0 mL of solution (D) with 1.0 mL of solution (IS), 1.5 mL of water R and dilute to 20.0 mL with ethanol R. For solution (H) (EG, DEG calibration solution, 0.025 mg each per mL, 0.1% with regards to sample concentration in solution (A)), dilute 2.0 mL of solution (D) to 20.0 mL with ethanol R. Mix 5.0 mL of this solution with 1.0 mL solution (IS), 1.5 mL of water R and dilute to 20.0 mL with ethanol R. For solution (I) (sensitivity control solution, 0.01 mg each per mL), dilute 2.0 mL of solution (D) to 20.0 mL with ethanol R. Mix 2.0 mL of this solution with 1.0 mL solution (IS), 1.5 mL of water R and dilute to 20.0 mL with ethanol R. Inject separately 1.0 µL each of solutions (A), (B), (E), (F), (G), (H) and (I) and record the chromatograms. After each injection, wash the needle first with water R, then with methanol/water (1:1 V/V) and, finally, with 2-propanol R. Depending on the dimensions of the liner used, the injection volume may need to be adjusted to avoid backflushing of the sample. Measure the response of the peaks corresponding to DEG, EG, propylene glycol and 1,3-butanediol in the chromatograms obtained. The substances, if present, are eluted at the following relative retention with reference to 1,3-butanediol (retention time about 14 minutes): propylene glycol about 0.83; EG about 0.87; and DEG about 1.20. The test is not valid unless the resolution between the peaks corresponding to EG and propylene glycol in the chromatogram obtained with solution (G) is at least 4.0. Also, the test is not valid unless, in the chromatogram obtained with solution (I), the signal-to-noise ratios of the peaks due to DEG and EG are both at least 10. Furthermore, the test is not valid unless, in the chromatogram obtained with solution (B), any peak having the same retention time as 1,3-butanediol is not more than 0.01 times the area of the peak corresponding to 1,3-butanediol in the chromatogram obtained with solution (A). The procedure was successfully applied to numerous samples from the market. However, as with all compendial procedures, it cannot be entirely excluded that certain excipients or sample components may interfere with the signals due to EG, DEG or the internal standard. In such cases, the use of a mass-selective detector may enhance the selectivity of
References
References Sonja Drobnjak; Detection and limit test of DEG and EG impurities in syrup products, CBS Edition: 134, 30 April 2025; https://camag.com/article/detection-and-limit-test-of-diethylene-glycol-and-ethylene-glycol-impurities-in-syrup-by-hptlc/ Si-Tong Zheng, Zi-Ying Wang, Zhen Liu, Yingxiang Du, Ling Cao, Sheng Tang, Hian Kee Lee, Yaozuo Yuan, Hai-Wei Shi; Rapid Determination of Trace Ethylene Glycol and Diethylene Glycol in Propylene Glycol-Contained Syrups by Ultrahigh-Performance Supercritical Fluid Chromatography-Mass Spectrometry after Precolumn Derivatization; Journal of Chromatography A; Volume 1737; 2024; https://doi.org/10.1016/j.chroma.2024.465433. Altamimy, Monerah A. et al.; A Selective Gas Chromatography–Tandem Mass Spectrometry Method for Quantitation of Ethylene and Diethylene Glycol in Paediatric Syrups; Heliyon; Volume 10; Issue 7; 2024; https://doi.org/10.1016/j.heliyon.2024.e27559. WHO Expert Committee on Specifications for Pharmaceutical Preparations: fifty-seventh report. Geneva: World Health Organization; 2024; Annex 4 (WHO Technical Report Series, No. 1052).
No counterparts indexed yet — search this title across all datasets
View raw JSON-LD
{
"@id": "https://www.openphar.org/data/phint/monographs/10-5-2",
"@type": "IndexedMonograph",
"prefLabel": {
"en": "Determination of diethylene glycol and ethylene glycol in liquid preparations for oral use"
},
"monographId": "10.5.2",
"edition": "PhInt-13",
"category": "monographs",
"definition": {
"en": "2025-02"
},
"sections": [
{
"name": "opening",
"text": "2025-02"
},
{
"name": "Introduction and scope",
"text": "Introduction and scope\n\nDiethylene glycol (DEG) and ethylene glycol (EG) are toxic substances commonly used as industrial solvents and antifreeze agents. Even small quantities can be fatal, particularly for children.\n\nOver the past decades, numerous incidents of medicine contamination with EG and DEG have been reported. These cases involved liquid preparations for oral use manufactured with excipients such as glycerol and propylene glycol that were contaminated, adulterated or mistakenly substituted with DEG or EG. Such incidents have resulted in hundreds of deaths worldwide, often through kidney failure.\n\nAlthough no definitive safe levels for human ingestion have been established, a detection threshold of 0.10 % for each substance is generally considered acceptable in raw materials and finished pharmaceutical products from a safety perspective.\n\nGas chromatography with a flame ionization detector (GC-FID) is a reliable and widely used analytical technique for the accurate and precise detection of volatile substances. It has frequently been applied for the determination of DEG and EG in pharmaceutical excipients and formulations. Other analytical techniques described in the literature include High-performance thin-layer chromatography (HPTLC) [1], Ultrahigh-performance supercritical fluid chromatography - Mass spectrometry after precolumn derivatization [2] and Gas chromatography - Tandem mass spectrometry [3].\n\nThe following text describes an HPTLC and a GC-FID method for the determination of DEG and EG in liquid preparations for oral use. National Quality Control Laboratories should be prepared to test samples from their markets for DEG and EG to safeguard patients from contaminated products. The selection of the analytical method should be based on the availability of suitable equipment and the training and expertise of laboratory personnel. The HPTLC method may thereby be particularly suitable for less-resourced laboratories.\n\nThe described HPTLC procedure is presented as a semiquantitative limit test, involving several manual operations and a visual comparison of band intensities. The sensitivity and precision of the method depend both on the analyst’s expertise and training and the performance of the equipment used. However, the procedure can also be implemented as a fully quantitative method, for example using automatic sample application and densitometric evaluation of chromatograms.\n\nDepending on whether it is implemented as a semiquantitative or quantitative method, the procedure may serve either as a screening tool for detecting non-compliance (to be followed by a confirmatory test) or as a complementary technique to corroborate results obtained with other quantitative procedure, such as the described GC method.\n\nLaboratories that confirm the presence of DEG or EG contamination in excipients or finished products should notify the relevant regulatory authorities without delay."
},
{
"name": "Determination by High-performance thin-layer chromatography (HPTLC)",
"text": "Determination by High-performance thin-layer chromatography (HPTLC)\n\nNote. EG and DEG exhibit similar RF values in the described HPTLC procedure. Reference solutions containing 50:50 (m/m) mixtures of DEG and EG are used to calibrate the analyte response. As a result, analysts determine the combined concentration of DEG and EG rather than quantifying each contaminant individually."
},
{
"name": "Procedure",
"text": "Procedure. Carry out the test as described under 1.18 High-Performance Thin-layer chromatography, using an HPTLC silica gel 60 F254 plate (2-10 µm) as the stationary phase.\n\nPrepare the following solutions:\n\nDeveloping solvent system. A freshly prepared mixture of water R, concentrated ammonia solution R, toluene R and acetone R (9.5:1:5:85 V/V/V/V). Add the solvents in the described order and mix.\n\nDerivatization reagent. Prepare a mixture of 0.75 g of potassium permanganate R, 5 g of sodium carbonate R and 0.625 mL of sodium hydroxide (~ 100 g/L) TS in 100 mL of water R.\n\nStock solutions\n\nFor solution (H1) (EG+DEG stock solution, 20% (m/m) with reference to the sample concentration in solutions S10, 10 mg EG + 10 mg DEG per mL), dissolve 500 mg of diethylene glycol RS and 500 mg of ethylene glycol RS in 50.0 mL of methanol R.\n\nFor solution (H2) (EG+DEG stock solution, 2% (m/m) with reference to the sample concentration in solutions S10, 1 mg EG + 1 mg DEG per mL), dilute 10.0 mL of solution (H1) to 100.0 mL with methanol R.\n\nFor solution (H3) (PG/Glycerol stock solution), transfer 5.0 g of propylene glycol R and 5.0 g of glycerol R to a 500 mL volumetric flask, add 400 mL of methanol R, sonicate for 5 minutes and make up to volume with the same solvent.\n\nSample solution\n\nFor solution (S10) (sample solution, 100 mg sample per mL), transfer 1.000 g of the liquid preparation for oral use under investigation to a 10.0 mL volumetric flask. Add 5 mL of methanol R, stopper the flask and shake vigorously. Make up to volume with methanol R, mix thoroughly and filtrate, if necessary.\n\nFor solution (S11) (EG and DEG spiked sample solution, 1.0 % (m/m)), transfer 1.000 g of the liquid preparation for oral use under investigation to a 10.0 mL volumetric flask. Add 1.0 mL of solution (R0) and 4 mL of methanol R, stopper the flask and shake vigorously. Make up to volume with methanol R, mix thoroughly and filtrate, if necessary.\n\nReference solution containing EG and DEG\n\nFor solution (R0) (EG+DEG reference solution, 10% (m/m) with reference to the sample concentration in solution (S10), 5 mg EG + 5 mg DEG per mL), transfer 10.0 mL of solution (H1) to a 20 mL volumetric flask and dilute to volume with methanol R.\n\nFor solution (R1) (EG+DEG reference solution, 5% (m/m) with reference to the sample concentration in solution (S10), 2.5 mg EG + 2.5 mg DEG per mL), transfer 5.0 mL of solution (H1) to a 20 mL volumetric flask, add 5.0 mL of solution (H3) and dilute to volume with methanol R.\n\nFor solution (R2) (EG+DEG reference solution, 1% (m/m) with reference to the sample concentration in solution (S10), 0.5 mg EG + 0.5 mg DEG per mL), transfer 5.0 mL of solution (H1) to a 100 mL volumetric flask, add 25.0 mL of solution (H3) and dilute to volume with methanol R.\n\nFor solution (R3) (EG+DEG reference solution, 0.2% (m/m) with reference to the sample concentration in solution (S10), 0.1 mg EG + 0.1 mg DEG per mL), transfer 10.0 mL of solution (H2) to a 100 mL volumetric flask, add 25.0 mL of solution (H3) and dilute to volume with methanol R.\n\nFor solution (R4) (EG+DEG reference solution, 0.1% (m/m) with reference to the sample concentration in solution (S10), 0.05 mg EG + 0.05 mg DEG per mL), transfer 5.0 mL of solution (H2) to a 100 mL volumetric flask, add 25.0 mL of solution (H3) and dilute to volume with methanol R.\n\nFor solution (R5) (EG+DEG reference solution, 0.05% (m/m) with reference to the sample concentration in solution (S10), 0.025 mg EG + 0.025 mg DEG per mL), transfer 2.5 mL of solution (H2) to a 100 mL volumetric flask, add 25.0 mL of solution (H3) and dilute to volume with methanol R.\n\nAnalysis. Apply 5 µL of each of solutions (S10), (S11), (R1), (R2), (R3), (R4) and (R5) as bands and dry them in air. Precondition the plate to control its activity and develop it in a saturated chamber. Remove the plate, dry it in a stream of air at room temperature and examine it under white light, short-wave and long-wave UV light.\n\nUse a pencil to lightly circle the spots that are visible in daylight and under UV light. The substances identified may originate from active ingredients, their impurities or degradants, excipients, or other matrix components.\n\nTo identify the spots due to EG/DEG, propylene glycol, glycerol and other components of the sample that are not visible in daylight and under UV light, spray the plate with the derivatization reagent and dry it in a stream of warm air for about 15 to 20 minutes. Let the plate rest for 5 minutes.\n\nExamine the plate under white light. Bright yellow spots should be visible. The following substances are eluted with the following RF values: sorbitol, if present, about 0.08; glycerol about 0.37; DEG and EG about 0.53; propylene glycol about 0.61.\n\nDetermine if components of the sample interfere with the EG/DEG determination by comparing the RF values of spots circled in daylight or UV light with the RF value of the spot due to EG/DEG after derivatization.\n\nThe test is not valid unless the chromatograms obtained with solutions (R1), (R2), and (R3) show three resolved spots due to propylene glycol, EG / DEG and glycerol and in the chromatogram obtained with solution (S11) the spot due to EG or DEG is free of interferences.\n\nDetermine whether a spot due to EG/DEG is present in the chromatogram obtained with solution (S10). If present, estimate the approximate percentage content of DEG or EG (m/m) in the liquid preparation for oral use under investigation by comparing the intensity of the spot due to EG or DEG in the chromatogram obtained with solution (S10) with the intensities of the spots due to EG/DEG in the chromatograms obtained with solutions (R1) to (R5)."
},
{
"name": "Determination by gas chromatography with flame-ionization detection (GC-FID)",
"text": "Determination by gas chromatography with flame-ionization detection (GC-FID)\n\nCarry out the test as described under 1.14.1 Chromatography, Gas chromatography using the internal standard method.\n\nFor the procedure, use a capillary glass or quartz column (30 m × 0.53 mm), the inner surface of which is coated with a layer of macrogol 20M R (1.0 μm). Maintain the temperature of the column at 100 °C for 5 minutes. Increase the temperature at a rate of 10 °C per minute to 245 °C and maintain it at this point for 4 minutes. Maintain the temperature of the injection port and the detector at 250 °C. Use helium R or nitrogen R as the carrier gas with a linear velocity of about 38 cm per second. Use split injection ratio of 1:20 and a flame-ionization detector for detection.\n\nThe retention times and the separation of peaks are similar when using helium R or nitrogen R as the carrier gas. Although the peaks are slightly sharper when using helium R, the use of nitrogen R is preferable from a sustainability perspective.\n\nLaboratories that can only obtain a column with a maximum temperature of 240 °C or below may change the temperature accordingly, if necessary. However, lowering the temperature may affect the ability of the method to clean the column of substances with a high boiling point thus deteriorating column performance over time.\n\nThe described procedure was validated using helium as a carrier gas. The use of nitrogen or hydrogen may also be suitable with little or no changes in peak resolution. Helium is a non-renewable gas that may be or eventually become difficult to source. Nitrogen and hydrogen can be produced on-demand using suitable generators.\n\nFor solution (IS) (10 mg IS per mL), weigh 0.500 g of the internal standard 1,3-butanediol R and dilute to 50.0 mL with water R.\n\nDuring the elaboration of the analytical procedure, it was noted that the peak due to 1,3-butanediol may show peak tailing when columns with thinner layers of macrogol are used. In such cases, 1,3 propanediol R was found to be a suitable alternative to 1,3-butanediol R.\n\nFor solution (A) (sample solution, 25 mg of sample per mL), weigh 0.500 g of the liquid preparation for oral use under investigation into a 20 mL volumetric flask, add 1.0 mL of solution (IS) and 1.0 mL of water R and mix thoroughly. Make up to volume with ethanol R and sonicate for 5 minutes. Place the solution in an ice bath for 15 minutes and filter.\n\nFor solution (B) (sample solution without IS), weigh 0.500 g of the liquid preparation for oral solution under investigation into a 20 mL volumetric flask, add 2.0 mL of water R and mix thoroughly. Make up to volume with ethanol R and sonicate for 5 minutes. Place the solution in an ice bath for 15 minutes and filter.\n\nFor solution (C) (EG, PG, DEG stock solution; 10 mg each per mL), weigh 1.000 g of each ethylene glycol RS, propylene glycol R and diethylene glycol RS and dilute to 100.0 mL with ethanol R.\n\nFor solution (D) (EG, PG, DEG stock solution; 1.0 mg each per mL), dilute 2.0 mL of solution (C) to 20.0 mL with ethanol R.\n\nFor solution (E) (EG, DEG calibration solution, 1.25 mg each per mL, 5% with regards to sample concentration in solution (A)), mix 25.0 mL of solution (C) with 10.0 mL of solution (IS), 15 mL of water R and dilute to 200.0 mL with ethanol R.\n\nFor solution (F) (EG, DEG calibration solution, 0.5 mg each per mL, 2% with regards to sample concentration in solution (A)), mix 1.0 mL of solution (C) with 1.0 mL of solution (IS), 1.5 mL of water R and dilute to 20.0 mL with ethanol R.\n\nFor solution (G) (EG, DEG calibration solution, 0.1 mg each per mL, 0.4% with regards to sample concentration in solution (A)), mix 2.0 mL of solution (D) with 1.0 mL of solution (IS), 1.5 mL of water R and dilute to 20.0 mL with ethanol R.\n\nFor solution (H) (EG, DEG calibration solution, 0.025 mg each per mL, 0.1% with regards to sample concentration in solution (A)), dilute 2.0 mL of solution (D) to 20.0 mL with ethanol R. Mix 5.0 mL of this solution with 1.0 mL solution (IS), 1.5 mL of water R and dilute to 20.0 mL with ethanol R.\n\nFor solution (I) (sensitivity control solution, 0.01 mg each per mL), dilute 2.0 mL of solution (D) to 20.0 mL with ethanol R. Mix 2.0 mL of this solution with 1.0 mL solution (IS), 1.5 mL of water R and dilute to 20.0 mL with ethanol R.\n\nInject separately 1.0 µL each of solutions (A), (B), (E), (F), (G), (H) and (I) and record the chromatograms. After each injection, wash the needle first with water R, then with methanol/water (1:1 V/V) and, finally, with 2-propanol R.\n\nDepending on the dimensions of the liner used, the injection volume may need to be adjusted to avoid backflushing of the sample.\n\nMeasure the response of the peaks corresponding to DEG, EG, propylene glycol and 1,3-butanediol in the chromatograms obtained. The substances, if present, are eluted at the following relative retention with reference to 1,3-butanediol (retention time about 14 minutes): propylene glycol about 0.83; EG about 0.87; and DEG about 1.20.\n\nThe test is not valid unless the resolution between the peaks corresponding to EG and propylene glycol in the chromatogram obtained with solution (G) is at least 4.0.\n\nAlso, the test is not valid unless, in the chromatogram obtained with solution (I), the signal-to-noise ratios of the peaks due to DEG and EG are both at least 10.\n\nFurthermore, the test is not valid unless, in the chromatogram obtained with solution (B), any peak having the same retention time as 1,3-butanediol is not more than 0.01 times the area of the peak corresponding to 1,3-butanediol in the chromatogram obtained with solution (A).\n\nThe procedure was successfully applied to numerous samples from the market. However, as with all compendial procedures, it cannot be entirely excluded that certain excipients or sample components may interfere with the signals due to EG, DEG or the internal standard. In such cases, the use of a mass-selective detector may enhance the selectivity of "
},
{
"name": "References",
"text": "References\n\nSonja Drobnjak; Detection and limit test of DEG and EG impurities in syrup products, CBS Edition: 134, 30 April 2025; https://camag.com/article/detection-and-limit-test-of-diethylene-glycol-and-ethylene-glycol-impurities-in-syrup-by-hptlc/\r\n\r\n\r\nSi-Tong Zheng, Zi-Ying Wang, Zhen Liu, Yingxiang Du, Ling Cao, Sheng Tang, Hian Kee Lee, Yaozuo Yuan, Hai-Wei Shi; Rapid Determination of Trace Ethylene Glycol and Diethylene Glycol in Propylene Glycol-Contained Syrups by Ultrahigh-Performance Supercritical Fluid Chromatography-Mass Spectrometry after Precolumn Derivatization; Journal of Chromatography A; Volume 1737; 2024; https://doi.org/10.1016/j.chroma.2024.465433.\r\n\r\n\r\nAltamimy, Monerah A. et al.; A Selective Gas Chromatography–Tandem Mass Spectrometry Method for Quantitation of Ethylene and Diethylene Glycol in Paediatric Syrups; Heliyon; Volume 10; Issue 7; 2024; https://doi.org/10.1016/j.heliyon.2024.e27559.\r\n\r\n\r\nWHO Expert Committee on Specifications for Pharmaceutical Preparations: fifty-seventh report. Geneva: World Health Organization; 2024; Annex 4 (WHO Technical Report Series, No. 1052)."
}
]
}