Japanese Pharmacopoeia · JP18
Digoxin
ジゴキシン
JP18-digoxin
Definition
Digoxin, when dried, contains not less than 96.
Appearance
Digoxin occurs as colorless or white crystals or a white crystalline powder. It is freely soluble in pyridine, slightly soluble in ethanol (95), very slightly soluble in acetic acid (100), and practically insoluble in water.
Test specifications
Identification
TestType-Identification
(1) Transfer 1 mg of Digoxin to a small test tube about 10 mm in inside diameter, dissolve in 1 mL of a solution of iron (III) chloride hexahydrate in acetic acid (100) (1 in 10,000), and underlay gently with 1 mL of sulfuric acid: at the zone of contact of the two liquids a brown ring free from a reddish color is produced, and the color of the upper layer near the contact zone changes to green through purple. Finally the entire acetic acid layer shows a green color through a deep blue color. (2) Determine the infrared absorption spectrum of Digoxin, previously dried, as directed in the potassium bro-mide disk method under Infrared Spectrophotometry <2.25>, and compare the spectrum with the Reference Spectrum: both spectra exhibit similar intensities of absorption at the same wave numbers. D Optical rotation <2.49> [a]20: +10.0 – +13.09(after dry-ing, 0.20 g, dehydratead pyridine, 10 mL, 100 mm).
Purity
TestType-Purity
(1) Clarity and color of solution—Dissolve 0.10 g of Digoxin in 15 mL of diluted ethanol (95) (4 in 5) by warm-ing at 709C: the solution is clear and colorless. (2) Related substances—Dissolve 25.0 mg of Digoxin in 50 mL of warm ethanol (95), cool, and add ethanol (95) to make exactly 100 mL. Pipet 10 mL of this solution, add 10 mL of water and dilute ethanol to make exactly 50 mL, and use this solution as the sample solution. Separately, dissolve exactly 5.0 mg of Gitoxin for Purity RS, previously dried under reduced pressure at 1059C for 1 hour, in a mixture of acetonitrile and water (7:3) to make exactly 200 mL. Pipet 2 mL of this solution, add dilute ethanol to make exactly 50 mL, and use this solution as the standard solution. Perform the test with exactly 10 mL each of the sample solution and standard solution as directed under Liquid Chromatography <2.01> according to the following conditions, and determine the peak areas, AT and AS, of gitoxin: AT is not larger than AS, and the total area of the peaks other than digoxin and gitoxin from the sample solution, obtained by the area per-centage method, is not more than 3z. Operating conditions— Detector, column, column temperature, mobile phase, and flow rate: Proceed as directed in the operating conditions in the Assay. Time span of measurement: About 4 times as long as the retention time of digoxin, beginning after the solvent peak. System suitability— Test for required detectability: Dissolve 25 mg of Digoxin in 50 mL of warm ethanol (95), cool, and add ethanol (95) to make 100 mL. To 10 mL of this solution add 10 mL of water and dilute ethanol to make 50 mL, and use this solution as the solution for system suitability test. Pipet 2 mL of the so-lution for system suitability test, and add dilute ethanol to make exactly 100 mL. Pipet 5 mL of this solution, and add dilute ethanol to make exactly 100 mL. Confirm that the peak area of digoxin obtained with 10 mL of this solution is equivalent to 0.07 to 0.13z of that with 10 mL of the solu-tion for system suitability test. System performance: Dissolve 25 mg of Digoxin in 50 mL of warm ethanol (95), cool, and add ethanol (95) to make 100 mL. To 10 mL of this solution add 5 mL of a solution of propyl parahydroxybenzoate in ethanol (95) (1 in 4000), 10 mL of water and dilute ethanol to make 50 mL. When the procedure is run with 10 mL of this solution under the above operating conditions, digoxin and propyl parahydroxyben-zoate are eluted in this order with the resolution between these peaks being not less than 5. System repeatability: When the test is repeated 6 times with 10 mL of the solution for system suitability test under the above operating conditions, the relative standard devia-tion of the peak area of digoxin is not more than 2.5z. Loss on drying <2.41> Not more than 1.0z (0.5 g, in vacu-um, 1059C, 1 hour). Residue on ignition <2.44> Not more than 0.5z (0.1 g).
Assay
TestType-Assay
Weigh accurately about 25 mg each of Digoxin and Digoxin RS, previously dried, dissolve in 50 mL of warm ethanol (95), cool, and add ethanol (95) to make exactly 100 mL. Pipet 10 mL of these solutions, add exactly 5 mL of the internal standard solution, 10 mL of water and dilute ethanol to make 50 mL, and use these solutions as the sample solution and standard solution. Perform the test with 10 mL each of the sample solution and standard solution as directed under Liquid Chromatography <2.01> according to the following conditions, and calculate the ratios, QT and QS, of the peak area of digoxin to that of the internal stand-ard. 309C. Mobile phase: A mixture of water and acetonitrile (7:3). Flow rate: Adjust so that the retention time of digoxin is about 10 minutes. System suitability— System performance: When the procedure is run with 10 mL of the standard solution under the above operating con-ditions, digoxin and the internal standard are eluted in this order with the resolution between these peaks being not less than 5. System repeatability: When the test is repeated 6 times with 10 mL of the standard solution under the above operat-ing conditions, the relative standard deviation of the ratio of the peak area of digoxin to that of the internal standard is not more than 1.0z.
Same substance in other pharmacopoeias
View raw JSON-LD
{
"@context": "https://www.openphar.org/ontology/context/pharmacopoeia.jsonld",
"@id": "https://www.openphar.org/data/jp/chemicals/digoxin",
"@type": "ChemicalDrugMonograph",
"prefLabel": {
"en": "Digoxin",
"ja": "ジゴキシン"
},
"monographId": "JP18-digoxin",
"publisher": "JP",
"status": "Official",
"version": "18",
"definition": {
"en": "Digoxin, when dried, contains not less than 96."
},
"appearance": {
"en": "Digoxin occurs as colorless or white crystals or a white crystalline powder. It is freely soluble in pyridine, slightly soluble in ethanol (95), very slightly soluble in acetic acid (100), and practically insoluble in water."
},
"testSpecification": [
{
"@type": "IdentificationSpecification",
"testName": {
"en": "Identification"
},
"testType": "TestType-Identification",
"testConditions": {
"en": "(1) Transfer 1 mg of Digoxin to a small test tube about 10 mm in inside diameter, dissolve in 1 mL of a solution of iron (III) chloride hexahydrate in acetic acid (100) (1 in 10,000), and underlay gently with 1 mL of sulfuric acid: at the zone of contact of the two liquids a brown ring free from a reddish color is produced, and the color of the upper layer near the contact zone changes to green through purple. Finally the entire acetic acid layer shows a green color through a deep blue color. (2) Determine the infrared absorption spectrum of Digoxin, previously dried, as directed in the potassium bro-mide disk method under Infrared Spectrophotometry <2.25>, and compare the spectrum with the Reference Spectrum: both spectra exhibit similar intensities of absorption at the same wave numbers. D Optical rotation <2.49> [a]20: +10.0 – +13.09(after dry-ing, 0.20 g, dehydratead pyridine, 10 mL, 100 mm)."
}
},
{
"@type": "PuritySpecification",
"testName": {
"en": "Purity"
},
"testType": "TestType-Purity",
"testConditions": {
"en": "(1) Clarity and color of solution—Dissolve 0.10 g of Digoxin in 15 mL of diluted ethanol (95) (4 in 5) by warm-ing at 709C: the solution is clear and colorless. (2) Related substances—Dissolve 25.0 mg of Digoxin in 50 mL of warm ethanol (95), cool, and add ethanol (95) to make exactly 100 mL. Pipet 10 mL of this solution, add 10 mL of water and dilute ethanol to make exactly 50 mL, and use this solution as the sample solution. Separately, dissolve exactly 5.0 mg of Gitoxin for Purity RS, previously dried under reduced pressure at 1059C for 1 hour, in a mixture of acetonitrile and water (7:3) to make exactly 200 mL. Pipet 2 mL of this solution, add dilute ethanol to make exactly 50 mL, and use this solution as the standard solution. Perform the test with exactly 10 mL each of the sample solution and standard solution as directed under Liquid Chromatography <2.01> according to the following conditions, and determine the peak areas, AT and AS, of gitoxin: AT is not larger than AS, and the total area of the peaks other than digoxin and gitoxin from the sample solution, obtained by the area per-centage method, is not more than 3z. Operating conditions— Detector, column, column temperature, mobile phase, and flow rate: Proceed as directed in the operating conditions in the Assay. Time span of measurement: About 4 times as long as the retention time of digoxin, beginning after the solvent peak. System suitability— Test for required detectability: Dissolve 25 mg of Digoxin in 50 mL of warm ethanol (95), cool, and add ethanol (95) to make 100 mL. To 10 mL of this solution add 10 mL of water and dilute ethanol to make 50 mL, and use this solution as the solution for system suitability test. Pipet 2 mL of the so-lution for system suitability test, and add dilute ethanol to make exactly 100 mL. Pipet 5 mL of this solution, and add dilute ethanol to make exactly 100 mL. Confirm that the peak area of digoxin obtained with 10 mL of this solution is equivalent to 0.07 to 0.13z of that with 10 mL of the solu-tion for system suitability test. System performance: Dissolve 25 mg of Digoxin in 50 mL of warm ethanol (95), cool, and add ethanol (95) to make 100 mL. To 10 mL of this solution add 5 mL of a solution of propyl parahydroxybenzoate in ethanol (95) (1 in 4000), 10 mL of water and dilute ethanol to make 50 mL. When the procedure is run with 10 mL of this solution under the above operating conditions, digoxin and propyl parahydroxyben-zoate are eluted in this order with the resolution between these peaks being not less than 5. System repeatability: When the test is repeated 6 times with 10 mL of the solution for system suitability test under the above operating conditions, the relative standard devia-tion of the peak area of digoxin is not more than 2.5z. Loss on drying <2.41> Not more than 1.0z (0.5 g, in vacu-um, 1059C, 1 hour). Residue on ignition <2.44> Not more than 0.5z (0.1 g)."
}
},
{
"@type": "AssaySpecification",
"testName": {
"en": "Assay"
},
"testType": "TestType-Assay",
"testConditions": {
"en": "Weigh accurately about 25 mg each of Digoxin and Digoxin RS, previously dried, dissolve in 50 mL of warm ethanol (95), cool, and add ethanol (95) to make exactly 100 mL. Pipet 10 mL of these solutions, add exactly 5 mL of the internal standard solution, 10 mL of water and dilute ethanol to make 50 mL, and use these solutions as the sample solution and standard solution. Perform the test with 10 mL each of the sample solution and standard solution as directed under Liquid Chromatography <2.01> according to the following conditions, and calculate the ratios, QT and QS, of the peak area of digoxin to that of the internal stand-ard. 309C. Mobile phase: A mixture of water and acetonitrile (7:3). Flow rate: Adjust so that the retention time of digoxin is about 10 minutes. System suitability— System performance: When the procedure is run with 10 mL of the standard solution under the above operating con-ditions, digoxin and the internal standard are eluted in this order with the resolution between these peaks being not less than 5. System repeatability: When the test is repeated 6 times with 10 mL of the standard solution under the above operat-ing conditions, the relative standard deviation of the ratio of the peak area of digoxin to that of the internal standard is not more than 1.0z."
}
}
],
"storageConditions": {
"en": "Containers—Tight containers."
}
}