Definition

Auranofin, when dried, contains not less than 98.

Appearance

Auranofin occurs as a white crystalline pow-der. It is very soluble in chloroform, freely soluble in metha-nol, sparingly soluble in ethanol (99.5), and practically in-soluble in water. It shows crystal polymorphism.

Test specifications

Identification

TestType-Identification

(1) To 50 mg of Auranofin add 3 mL of water, 3 mL of nitric acid and 3 mL of sulfuric acid, shake, and allow to stand: golden colored suspended matters are produced. Determine the infrared absorption spectrum of Auranofin as directed in the paste method under Infrared Spectrophotometry <2.25>, and compare the spectrum with the Reference Spectrum or the spectrum of Auranofin RS: both spectra exhibit similar intensities of absorption at the same wave numbers. Prepare the test solution with 1 mg of Auranofin as directed under Oxygen Flask Combustion Method <1.06>, using 10 mL of water as the absorbing liquid. Wash out the test solution into a Nessler tube with water to make 30 mL. Add 10 mL of dilute sulfuric acid, 3 mL of hexaammonium heptamolybdate-sulfuric acid TS and 0.1 mL of tin (II) chlo-ride TS, shake, and allow to stand for 10 to 15 minutes: a blue color is developed. D Optical rotation <2.49> [a]20: -54.0 – -62.09(after dry-ing, 0.2 g, methanol, 20 mL, 100 mm).

Purity

TestType-Purity

(1) Chloride <1.03>—Put 0.5 g of Auranofin in a porcelain crucible, add 0.25 g of anhydrous sodium carbon-ate, mix well, and ignite until the carbonized substance is dis-appeared. After cooling, add 20 mL of water, heat, and filter after cooling. Wash the residue with 20 mL of water, combine the filtrate and the washings, neutralize with dilute nitric acid, then add 6 mL of dilute nitric acid and water to make 50 mL. Perform the test using this solution as the test solution. Prepare the control solution as follows: Dissolve 0.25 g of anhydrous sodium carbonate in 20 mL of water, neutralize with dilute nitric acid, add 0.50 mL of 0.01 mol/L hydrochloric acid, 6 mL of dilute nitric acid, and water to make 50 mL (not more than 0.036z). Heavy metals <1.07>—Proceed with 1.0 g of Auranofin according to Method 2, and perform the test. Prepare the control solution with 2.0 mL of Standard Lead Solution (not more than 20 ppm). Arsenic <1.11>—Put 0.5 g of Auranofin in a Kjeldahl flask, add cautiously 2 mL of sulfuric acid and 5 mL of nitric acid, and heat until the solution becomes almost color-less. After cooling, add 15 mL of a saturated solution of am-monium oxalate monohydrate, heat until white fumes are evolved, and concentrate to 1 to 2 mL. Then, add 3 mL of water and 1 drop of methyl orange TS, neutralize with am-monia solution (28), filter, and perform the test using the fil-trate as the test solution: the color is not darker than that of the following control solution. Control solution: Heat a mixture of 2 mL of sulfuric acid and 5 mL of nitric acid until white fumes are no longer evolved. After cooling, add 15 mL of a saturated solution of ammonium oxalate monohydrate, heat until white fumes are evolved, and concentrate to 1 to 2 mL. Add 3 mL of water and 1 drop of methyl orange TS, neutralize with ammonia solution (28), and filter. To the filtrate add 2.0 mL of Stand-ard Arsenic Solution, then proceed in the same manner as for the test solution (not more than 4 ppm). Related substances—Dissolve 50 mg of Auranofin in 5 mL of chloroform, and use this solution as the sample so-lution. Pipet 1 mL of the sample solution, and add chlo-roform to make exactly 100 mL. To exactly 3 mL of this so-lution add chloroform to make exactly 10 mL, and use this solution as the standard solution. Perform the test with these solutions as directed under Thin-layer Chromatography <2.03>. Spot 10 mL each of the sample solution and standard solution on a plate of silica gel for thin-layer chromatogra-phy. Develop the plate with a mixture of chloroform and acetone (4:1) to a distance of about 10 cm, and air-dry the plate. Dry the plate, furthermore, at 809C for 30 minutes. After cooling, allow the plate to stand in a iodine vapor for 30 minutes: the spots other than the principal spot obtained from the sample solution are not more intense than the spot from the standard solution. Loss on drying <2.41> Not more than 0.5z (1 g, 1059C, 3 hours).

Assay

TestType-Assay

Weigh accurately about 20 mg each of Auranofin and Auranofin RS, both previously dried, dissolve each in 10 mL of a mixture of water and acetonitrile (1:1), and add exactly 5 mL each of the internal standard solution. Then add a mixture of water and acetonitrile (1:1) to make 100 mL, and use these solutions as the sample solution and the standard solution, respectively. Perform the test with 10 mL each of the sample solution and standard solution as directed under Liquid Chromatography <2.01> according to the fol-lowing conditions, and calculate the ratios, QT and QS, of JP XVIII Official Monographs / Auranofin Tablets 497 ‌the peak area of auranofin to that of the internal standard. Amount (mg) of auranofin (C20H34AuO9PS) = MS × QT/QS MS: Amount (mg) of Auranofin RS taken Internal standard solution—A solution of butyl para-hydroxybenzoate in a mixture of water and acetonitrile (1:1) (3 in 1250). Operating conditions— Detector: An ultraviolet absorption photometer (wave-length: 230 nm). Column: A stainless steel column 4 mm in inside diameter and 15 cm in length, packed with octadecylsilanized silica gel for liquid chromatography (5 mm in particle diameter). Column temperature: A constant temperature of about 259C. Mobile phase: A mixture of sodium dihydrogen phosphate dihydrate solution (1 in 100), tetrahydrofuran and aceto-nitrile (12:5:3). Flow rate: Adjust so that the retention time of auranofin is about 6 minutes. System suitability— System performance: When the procedure is run with 10 mL of the standard solution under the above operating con-ditions, auranofin and the internal standard are eluted in this order with the resolution between these peaks being not less than 9. System repeatability: When the test is repeated 6 times with 10 mL of the standard solution under the above operat-ing conditions, the relative standard deviation of the ratio of the peak area of auranofin to that of the internal standard is not more than 1.0z.

No counterparts indexed yet — search this title across all datasets

View raw JSON-LD
{
  "@context": "https://www.openphar.org/ontology/context/pharmacopoeia.jsonld",
  "@id": "https://www.openphar.org/data/jp/chemicals/auranofin",
  "@type": "ChemicalDrugMonograph",
  "prefLabel": {
    "en": "Auranofin",
    "ja": "オーラノフィン"
  },
  "monographId": "JP18-auranofin",
  "publisher": "JP",
  "status": "Official",
  "version": "18",
  "molecularFormula": "C20H34AuO9PS",
  "molecularWeight": 678.48,
  "definition": {
    "en": "Auranofin, when dried, contains not less than 98."
  },
  "appearance": {
    "en": "Auranofin occurs as a white crystalline pow-der. It is very soluble in chloroform, freely soluble in metha-nol, sparingly soluble in ethanol (99.5), and practically in-soluble in water. It shows crystal polymorphism."
  },
  "testSpecification": [
    {
      "@type": "IdentificationSpecification",
      "testName": {
        "en": "Identification"
      },
      "testType": "TestType-Identification",
      "testConditions": {
        "en": "(1) To 50 mg of Auranofin add 3 mL of water, 3 mL of nitric acid and 3 mL of sulfuric acid, shake, and allow to stand: golden colored suspended matters are produced. Determine the infrared absorption spectrum of Auranofin as directed in the paste method under Infrared Spectrophotometry <2.25>, and compare the spectrum with the Reference Spectrum or the spectrum of Auranofin RS: both spectra exhibit similar intensities of absorption at the same wave numbers. Prepare the test solution with 1 mg of Auranofin as directed under Oxygen Flask Combustion Method <1.06>, using 10 mL of water as the absorbing liquid. Wash out the test solution into a Nessler tube with water to make 30 mL. Add 10 mL of dilute sulfuric acid, 3 mL of hexaammonium heptamolybdate-sulfuric acid TS and 0.1 mL of tin (II) chlo-ride TS, shake, and allow to stand for 10 to 15 minutes: a blue color is developed. D Optical rotation <2.49> [a]20: -54.0 – -62.09(after dry-ing, 0.2 g, methanol, 20 mL, 100 mm)."
      }
    },
    {
      "@type": "PuritySpecification",
      "testName": {
        "en": "Purity"
      },
      "testType": "TestType-Purity",
      "testConditions": {
        "en": "(1) Chloride <1.03>—Put 0.5 g of Auranofin in a porcelain crucible, add 0.25 g of anhydrous sodium carbon-ate, mix well, and ignite until the carbonized substance is dis-appeared. After cooling, add 20 mL of water, heat, and filter after cooling. Wash the residue with 20 mL of water, combine the filtrate and the washings, neutralize with dilute nitric acid, then add 6 mL of dilute nitric acid and water to make 50 mL. Perform the test using this solution as the test solution. Prepare the control solution as follows: Dissolve 0.25 g of anhydrous sodium carbonate in 20 mL of water, neutralize with dilute nitric acid, add 0.50 mL of 0.01 mol/L hydrochloric acid, 6 mL of dilute nitric acid, and water to make 50 mL (not more than 0.036z). Heavy metals <1.07>—Proceed with 1.0 g of Auranofin according to Method 2, and perform the test. Prepare the control solution with 2.0 mL of Standard Lead Solution (not more than 20 ppm). Arsenic <1.11>—Put 0.5 g of Auranofin in a Kjeldahl flask, add cautiously 2 mL of sulfuric acid and 5 mL of nitric acid, and heat until the solution becomes almost color-less. After cooling, add 15 mL of a saturated solution of am-monium oxalate monohydrate, heat until white fumes are evolved, and concentrate to 1 to 2 mL. Then, add 3 mL of water and 1 drop of methyl orange TS, neutralize with am-monia solution (28), filter, and perform the test using the fil-trate as the test solution: the color is not darker than that of the following control solution. Control solution: Heat a mixture of 2 mL of sulfuric acid and 5 mL of nitric acid until white fumes are no longer evolved. After cooling, add 15 mL of a saturated solution of ammonium oxalate monohydrate, heat until white fumes are evolved, and concentrate to 1 to 2 mL. Add 3 mL of water and 1 drop of methyl orange TS, neutralize with ammonia solution (28), and filter. To the filtrate add 2.0 mL of Stand-ard Arsenic Solution, then proceed in the same manner as for the test solution (not more than 4 ppm). Related substances—Dissolve 50 mg of Auranofin in 5 mL of chloroform, and use this solution as the sample so-lution. Pipet 1 mL of the sample solution, and add chlo-roform to make exactly 100 mL. To exactly 3 mL of this so-lution add chloroform to make exactly 10 mL, and use this solution as the standard solution. Perform the test with these solutions as directed under Thin-layer Chromatography <2.03>. Spot 10 mL each of the sample solution and standard solution on a plate of silica gel for thin-layer chromatogra-phy. Develop the plate with a mixture of chloroform and acetone (4:1) to a distance of about 10 cm, and air-dry the plate. Dry the plate, furthermore, at 809C for 30 minutes. After cooling, allow the plate to stand in a iodine vapor for 30 minutes: the spots other than the principal spot obtained from the sample solution are not more intense than the spot from the standard solution. Loss on drying <2.41> Not more than 0.5z (1 g, 1059C, 3 hours)."
      }
    },
    {
      "@type": "AssaySpecification",
      "testName": {
        "en": "Assay"
      },
      "testType": "TestType-Assay",
      "testConditions": {
        "en": "Weigh accurately about 20 mg each of Auranofin and Auranofin RS, both previously dried, dissolve each in 10 mL of a mixture of water and acetonitrile (1:1), and add exactly 5 mL each of the internal standard solution. Then add a mixture of water and acetonitrile (1:1) to make 100 mL, and use these solutions as the sample solution and the standard solution, respectively. Perform the test with 10 mL each of the sample solution and standard solution as directed under Liquid Chromatography <2.01> according to the fol-lowing conditions, and calculate the ratios, QT and QS, of JP XVIII Official Monographs / Auranofin Tablets 497 ‌the peak area of auranofin to that of the internal standard. Amount (mg) of auranofin (C20H34AuO9PS) = MS × QT/QS MS: Amount (mg) of Auranofin RS taken Internal standard solution—A solution of butyl para-hydroxybenzoate in a mixture of water and acetonitrile (1:1) (3 in 1250). Operating conditions— Detector: An ultraviolet absorption photometer (wave-length: 230 nm). Column: A stainless steel column 4 mm in inside diameter and 15 cm in length, packed with octadecylsilanized silica gel for liquid chromatography (5 mm in particle diameter). Column temperature: A constant temperature of about 259C. Mobile phase: A mixture of sodium dihydrogen phosphate dihydrate solution (1 in 100), tetrahydrofuran and aceto-nitrile (12:5:3). Flow rate: Adjust so that the retention time of auranofin is about 6 minutes. System suitability— System performance: When the procedure is run with 10 mL of the standard solution under the above operating con-ditions, auranofin and the internal standard are eluted in this order with the resolution between these peaks being not less than 9. System repeatability: When the test is repeated 6 times with 10 mL of the standard solution under the above operat-ing conditions, the relative standard deviation of the ratio of the peak area of auranofin to that of the internal standard is not more than 1.0z."
      }
    }
  ],
  "storageConditions": {
    "en": "Containers—Tight containers."
  }
}