Japanese Pharmacopoeia · JP18

Atenolol

アテノロール

JP18-atenolol

JP
Formula
C14H22N2O3
Mw
266.34
Version
18

Definition

Atenolol, when dried, contains not less than 99.

Appearance

Atenolol occurs as a white to pale yellow crys-talline powder. It is freely soluble in methanol and in acetic acid (100), soluble in ethanol (99.5), and slightly soluble in water. A solution of Atenolol in methanol (1 in 25) shows no op-tical rotation.

Test specifications

Identification

TestType-Identification

(1) Determine the absorption spectrum of a solution of Atenolol in methanol (1 in 50,000) as directed under Ultraviolet-visible Spectrophotometry <2.24>, and compare the spectrum with the Reference Spectrum: both spectra exhibit similar intensities of absorption at the same wavelengths. (2) Determine the infrared absorption spectrum of Atenolol as directed in the potassium bromide disk method under Infrared Spectrophotometry <2.25>, and compare the spectrum with the Reference Spectrum: both spectra exhibit similar intensities of absorption at the same wave numbers. Melting Pint <2.60> 152 – 1569C

Purity

TestType-Purity

(1) Heavy metals <1.07>—Proceed with 1.0 g of Atenolol according to Method 2, and perform the test. Pre-pare the control solution with 2.0 mL of Standard Lead So-lution (not more than 20 ppm). (2) Related substances—Dissolve 50 mg of Atenolol in 25 mL of the mobile phase, and use this solution as the sam-ple solution. Pipet 1 mL of the sample solution, add the mo-bile phase to make exactly 200 mL, and use this solution as the standard solution. Perform the test with exactly 10 mL each of the sample solution and standard solution as directed under Liquid Chromatography <2.01> according to the fol-lowing conditions, and determine each peak area by the automatic integration method: the area of the peak other than atenolol obtained from the sample solution is not larger than 1/2 times the peak area of atenolol from the standard solution, and the total area of the peaks other than atenolol from the sample solution is not larger than the peak area of atenolol from the standard solution. Operating conditions— Detector: An ultraviolet absorption photometer (wave-length: 226 nm). Column: A stainless steel column 4.6 mm in inside diame-ter and 15 cm in length, packed with octadecylsilanized silica gel for liquid chromatography (5 mm in particle diameter). Column temperature: A constant temperature of about 259C. Mobile phase: Dissolve 3.4 g of potassium dihydrogen phosphate in 1000 mL of water, and adjust to pH 3.0 with phosphoric acid. To 40 volume of this solution add 9 volume of methanol and 1 volume of tetrahydrofuran. Dissolve 1 g of sodium 1-octanesulfonate and 0.4 g of tetrabutylammo-nium hydrogensulfate in 1000 mL of this solution. Flow rate: Adjust so that the retention time of atenolol is about 8 minutes. Time span of measurement: About 4 times as long as the retention time of atenolol. System suitability— Test for required detectability: To exactly 10 mL of the standard solution add the mobile phase to make exactly 50 mL. Confirm that the peak area of atenolol obtained with 10 mL of this solution is equivalent to 14 to 26z of that with 10 mL of the standard solution. System performance: When the procedure is run with 10 mL of the standard solution under the above operating con-ditions, the number of theoretical plates and the symmetry factor of the peak of atenolol are not less than 5000 and not more than 1.5, respectively. System repeatability: When the test is repeated 6 times with 10 mL of the standard solution under the above operat-ing conditions, the relative standard deviation of the peak area of atenolol is not more than 1.0z. Loss on drying <2.41> Not more than 0.5z (1 g, 1059C, 3 hours). Residue on ignition <2.44> Not more than 0.2z (1 g).

Assay

TestType-Assay

Weigh accurately about 0.3 g of Atenolol, previ-ously dried, dissolve in 100 mL of acetic acid (100), and titrate <2.50> with 0.1 mol/L perchloric acid VS (potentio-metric titration). Perform a blank determination in the same manner, and make any necessary correction. Each mL of 0.1 mol/L perchloric acid VS = 26.63 mg of C14H22N2O3

Same substance in other pharmacopoeias

View raw JSON-LD
{
  "@context": "https://www.openphar.org/ontology/context/pharmacopoeia.jsonld",
  "@id": "https://www.openphar.org/data/jp/chemicals/atenolol",
  "@type": "ChemicalDrugMonograph",
  "prefLabel": {
    "en": "Atenolol",
    "ja": "アテノロール"
  },
  "monographId": "JP18-atenolol",
  "publisher": "JP",
  "status": "Official",
  "version": "18",
  "molecularFormula": "C14H22N2O3",
  "molecularWeight": 266.34,
  "definition": {
    "en": "Atenolol, when dried, contains not less than 99."
  },
  "appearance": {
    "en": "Atenolol occurs as a white to pale yellow crys-talline powder. It is freely soluble in methanol and in acetic acid (100), soluble in ethanol (99.5), and slightly soluble in water. A solution of Atenolol in methanol (1 in 25) shows no op-tical rotation."
  },
  "testSpecification": [
    {
      "@type": "IdentificationSpecification",
      "testName": {
        "en": "Identification"
      },
      "testType": "TestType-Identification",
      "testConditions": {
        "en": "(1) Determine the absorption spectrum of a solution of Atenolol in methanol (1 in 50,000) as directed under Ultraviolet-visible Spectrophotometry <2.24>, and compare the spectrum with the Reference Spectrum: both spectra exhibit similar intensities of absorption at the same wavelengths. (2) Determine the infrared absorption spectrum of Atenolol as directed in the potassium bromide disk method under Infrared Spectrophotometry <2.25>, and compare the spectrum with the Reference Spectrum: both spectra exhibit similar intensities of absorption at the same wave numbers. Melting Pint <2.60> 152 – 1569C"
      }
    },
    {
      "@type": "PuritySpecification",
      "testName": {
        "en": "Purity"
      },
      "testType": "TestType-Purity",
      "testConditions": {
        "en": "(1) Heavy metals <1.07>—Proceed with 1.0 g of Atenolol according to Method 2, and perform the test. Pre-pare the control solution with 2.0 mL of Standard Lead So-lution (not more than 20 ppm). (2) Related substances—Dissolve 50 mg of Atenolol in 25 mL of the mobile phase, and use this solution as the sam-ple solution. Pipet 1 mL of the sample solution, add the mo-bile phase to make exactly 200 mL, and use this solution as the standard solution. Perform the test with exactly 10 mL each of the sample solution and standard solution as directed under Liquid Chromatography <2.01> according to the fol-lowing conditions, and determine each peak area by the automatic integration method: the area of the peak other than atenolol obtained from the sample solution is not larger than 1/2 times the peak area of atenolol from the standard solution, and the total area of the peaks other than atenolol from the sample solution is not larger than the peak area of atenolol from the standard solution. Operating conditions— Detector: An ultraviolet absorption photometer (wave-length: 226 nm). Column: A stainless steel column 4.6 mm in inside diame-ter and 15 cm in length, packed with octadecylsilanized silica gel for liquid chromatography (5 mm in particle diameter). Column temperature: A constant temperature of about 259C. Mobile phase: Dissolve 3.4 g of potassium dihydrogen phosphate in 1000 mL of water, and adjust to pH 3.0 with phosphoric acid. To 40 volume of this solution add 9 volume of methanol and 1 volume of tetrahydrofuran. Dissolve 1 g of sodium 1-octanesulfonate and 0.4 g of tetrabutylammo-nium hydrogensulfate in 1000 mL of this solution. Flow rate: Adjust so that the retention time of atenolol is about 8 minutes. Time span of measurement: About 4 times as long as the retention time of atenolol. System suitability— Test for required detectability: To exactly 10 mL of the standard solution add the mobile phase to make exactly 50 mL. Confirm that the peak area of atenolol obtained with 10 mL of this solution is equivalent to 14 to 26z of that with 10 mL of the standard solution. System performance: When the procedure is run with 10 mL of the standard solution under the above operating con-ditions, the number of theoretical plates and the symmetry factor of the peak of atenolol are not less than 5000 and not more than 1.5, respectively. System repeatability: When the test is repeated 6 times with 10 mL of the standard solution under the above operat-ing conditions, the relative standard deviation of the peak area of atenolol is not more than 1.0z. Loss on drying <2.41> Not more than 0.5z (1 g, 1059C, 3 hours). Residue on ignition <2.44> Not more than 0.2z (1 g)."
      }
    },
    {
      "@type": "AssaySpecification",
      "testName": {
        "en": "Assay"
      },
      "testType": "TestType-Assay",
      "testConditions": {
        "en": "Weigh accurately about 0.3 g of Atenolol, previ-ously dried, dissolve in 100 mL of acetic acid (100), and titrate <2.50> with 0.1 mol/L perchloric acid VS (potentio-metric titration). Perform a blank determination in the same manner, and make any necessary correction. Each mL of 0.1 mol/L perchloric acid VS = 26.63 mg of C14H22N2O3"
      }
    }
  ],
  "storageConditions": {
    "en": "Containers—Tight containers."
  }
}