Japanese Pharmacopoeia · JP18
Aciclovir
アシクロビル
JP18-aciclovir
- Formula
- C8H11N5O3
- CAS
- 59277-89-3
- Mw
- 225.2
- Version
- 18
Definition
Aciclovir contains not less than 98.
Appearance
Aciclovir occurs as a white to pale yellow-white crystalline powder. It is slightly soluble in water and very slightly soluble in ethanol (99.5). It dissolves in 0.1 mol/L hydrochloric acid TS and in dilute sodium hydroxide TS.
Test specifications
Identification
TestType-Identification
(1) Determine the absorption spectrum of a solution of Aciclovir in 0.1 mol/L hydrochloric acid TS (1 in 100,000) as directed under Ultraviolet-visible Spectropho-tometry <2.24>, and compare the spectrum with the Refer-ence Spectrum or the spectrum of a solution of Aciclovir RS prepared in the same manner as the sample solution: both spectra exhibit similar intensities of absorption at the same wavelengths. (2) Determine the infrared absorption spectrum of Aciclovir as directed in the potassium bromide disk method under Infrared Spectrophotometry <2.25>, and compare the spectrum with the Reference Spectrum or the spectrum of Aciclovir RS: both spectra exhibit similar intensities of ab-sorption at the same wave numbers.
Purity
TestType-Purity
(1) Clarity and color of solution—Dissolve 0.5 g of Aciclovir in 20 mL of dilute sodium hydroxide TS: the so-lution is clear and is not more colored than the following control solution. Control solution: To 2.5 mL of Matching Fluid F add diluted dilute hydrochloric acid (1 in 10) to make 100 mL. Heavy metals <1.07>—Proceed with 1.0 g of Aciclovir according to Method 2, and perform the test. Prepare the control solution with 1.0 mL of Standard Lead Solution (not more than 10 ppm). Related substances—Use the sample solution ob-tained in the Assay as the sample solution. Separately, weigh accurately about 25 mg of guanine, dissolve in 50 mL of dilute sodium hydroxide TS, and add the mobile phase to make exactly 100 mL. Pipet 2 mL of this solution, add the mobile phase to make exactly 100 mL, and use this solution as the standard solution. Perform the test with exactly 10 mL each of the sample solution and standard solution as directed under Liquid Chromatography <2.01> according to the fol-lowing conditions. Determine the peak areas of guanine, AT and AS, and calculate the amount of guanine by the follow-ing equation: it is not more than 0.7z. Determine each peak area from the sample solution by the automatic integration method, and calculate the amount of each related substance other than aciclovir and guanine by the area percentage method: it is not more than 0.2z. Furthermore, the sum of the amount of guanine calculated above and the amounts of related substances determined by the area percentage method is not more than 1.5z. Amount (mg) of aciclovir (C8H11N5O3) = MS × AT/AS MS: Amount (mg) of Aciclovir RS taken, calculated on the anhydrous basis Operating conditions— Detector: An ultraviolet absorption photometer (wave-length: 254 nm). Column: A stainless steel column 4.6 mm in inside diame-ter and 10 cm in length, packed with octadecylsilanized silica gel for liquid chromatography (3 mm in particle diameter). Column temperature: A constant temperature of about 209C. Mobile phase: Dissolve 1.0 g of sodium 1-decanesulfonate and 6.0 g of sodium dihydrogen phosphate dihydrate in 1000 mL of water, and adjust the pH to 3.0 with phosphoric acid. To this solution add 40 mL of acetonitrile. Flow rate: Adjust so that the retention time of aciclovir is about 3 minutes. System suitability— System performance: Dissolve 0.1 g of Aciclovir in 5 mL of dilute sodium hydroxide TS, add 2 mL of a solution of guanine in dilute sodium hydroxide TS (1 in 4000), and add the mobile phase to make 100 mL. When the procedure is run with 10 mL of this solution under the above operating conditions, aciclovir and guanine are eluted in this order with the resolution between these peaks being not less than Amount (z) of guanine = MS/MT MS: Amount (mg) of guanine taken × AT/AS × 2/5 17. System repeatability: When the test is repeated 6 times with 10 mL of the standard solution under the above operat- MT: Amount (mg) of Aciclovir taken Operating conditions— Detector, column, column temperature, mobile phase, and flow rate: Proceed as directed in the operating conditions in the Assay. Time span of measurement: About 8 times as long as the retention time of aciclovir, beginning after the solvent peak. System suitability— System performance: Proceed as directed in the system suitability in the Assay. Test for required detectability: To 1 mL of the sample solution add the mobile phase to make 100 mL, and use this solution as the solution for system suitability test. Pipet 1 mL of the solution for system suitability test, and add the mobile phase to make exactly 10 mL. Confirm that the peak area of aciclovir obtained with 10 mL of this solution is equivalent to 7 to 13z of that with 10 mL of the solution for system suitability test. System repeatability: When the test is repeated 6 times with 10 mL of the standard solution under the above operat-ing conditions, the relative standard deviation of the peak area of guanine is not more than 2.0z. Water <2.48> Not more than 6.0z (50 mg, coulometric titration). Residue on ignition <2.44> Not more than 0.1z (1 g).
Assay
TestType-Assay
Weigh accurately about 20 mg each of Aciclovir and Aciclovir RS (separately determine the water <2.48> in the same manner as Aciclovir), dissolve each in 1 mL of dilute sodium hydroxide TS, add the mobile phase to make exactly 20 mL each, and use these solutions as the sample solution and the standard solution, respectively. Perform the test with exactly 10 mL each of the sample solution and standard solution as directed under Liquid Chromatography <2.01> according to the following conditions, and determine the peak areas, AT and AS, of aciclovir in each solution. ing conditions, the relative standard deviation of the peak area of aciclovir is not more than 1.0z.
Same substance in other pharmacopoeias
View raw JSON-LD
{
"@context": "https://www.openphar.org/ontology/context/pharmacopoeia.jsonld",
"@id": "https://www.openphar.org/data/jp/chemicals/aciclovir",
"@type": "ChemicalDrugMonograph",
"prefLabel": {
"en": "Aciclovir",
"ja": "アシクロビル"
},
"monographId": "JP18-aciclovir",
"publisher": "JP",
"status": "Official",
"version": "18",
"molecularFormula": "C8H11N5O3",
"molecularWeight": 225.2,
"casNumber": "59277-89-3",
"definition": {
"en": "Aciclovir contains not less than 98."
},
"appearance": {
"en": "Aciclovir occurs as a white to pale yellow-white crystalline powder. It is slightly soluble in water and very slightly soluble in ethanol (99.5). It dissolves in 0.1 mol/L hydrochloric acid TS and in dilute sodium hydroxide TS."
},
"testSpecification": [
{
"@type": "IdentificationSpecification",
"testName": {
"en": "Identification"
},
"testType": "TestType-Identification",
"testConditions": {
"en": "(1) Determine the absorption spectrum of a solution of Aciclovir in 0.1 mol/L hydrochloric acid TS (1 in 100,000) as directed under Ultraviolet-visible Spectropho-tometry <2.24>, and compare the spectrum with the Refer-ence Spectrum or the spectrum of a solution of Aciclovir RS prepared in the same manner as the sample solution: both spectra exhibit similar intensities of absorption at the same wavelengths. (2) Determine the infrared absorption spectrum of Aciclovir as directed in the potassium bromide disk method under Infrared Spectrophotometry <2.25>, and compare the spectrum with the Reference Spectrum or the spectrum of Aciclovir RS: both spectra exhibit similar intensities of ab-sorption at the same wave numbers."
}
},
{
"@type": "PuritySpecification",
"testName": {
"en": "Purity"
},
"testType": "TestType-Purity",
"testConditions": {
"en": "(1) Clarity and color of solution—Dissolve 0.5 g of Aciclovir in 20 mL of dilute sodium hydroxide TS: the so-lution is clear and is not more colored than the following control solution. Control solution: To 2.5 mL of Matching Fluid F add diluted dilute hydrochloric acid (1 in 10) to make 100 mL. Heavy metals <1.07>—Proceed with 1.0 g of Aciclovir according to Method 2, and perform the test. Prepare the control solution with 1.0 mL of Standard Lead Solution (not more than 10 ppm). Related substances—Use the sample solution ob-tained in the Assay as the sample solution. Separately, weigh accurately about 25 mg of guanine, dissolve in 50 mL of dilute sodium hydroxide TS, and add the mobile phase to make exactly 100 mL. Pipet 2 mL of this solution, add the mobile phase to make exactly 100 mL, and use this solution as the standard solution. Perform the test with exactly 10 mL each of the sample solution and standard solution as directed under Liquid Chromatography <2.01> according to the fol-lowing conditions. Determine the peak areas of guanine, AT and AS, and calculate the amount of guanine by the follow-ing equation: it is not more than 0.7z. Determine each peak area from the sample solution by the automatic integration method, and calculate the amount of each related substance other than aciclovir and guanine by the area percentage method: it is not more than 0.2z. Furthermore, the sum of the amount of guanine calculated above and the amounts of related substances determined by the area percentage method is not more than 1.5z. Amount (mg) of aciclovir (C8H11N5O3) = MS × AT/AS MS: Amount (mg) of Aciclovir RS taken, calculated on the anhydrous basis Operating conditions— Detector: An ultraviolet absorption photometer (wave-length: 254 nm). Column: A stainless steel column 4.6 mm in inside diame-ter and 10 cm in length, packed with octadecylsilanized silica gel for liquid chromatography (3 mm in particle diameter). Column temperature: A constant temperature of about 209C. Mobile phase: Dissolve 1.0 g of sodium 1-decanesulfonate and 6.0 g of sodium dihydrogen phosphate dihydrate in 1000 mL of water, and adjust the pH to 3.0 with phosphoric acid. To this solution add 40 mL of acetonitrile. Flow rate: Adjust so that the retention time of aciclovir is about 3 minutes. System suitability— System performance: Dissolve 0.1 g of Aciclovir in 5 mL of dilute sodium hydroxide TS, add 2 mL of a solution of guanine in dilute sodium hydroxide TS (1 in 4000), and add the mobile phase to make 100 mL. When the procedure is run with 10 mL of this solution under the above operating conditions, aciclovir and guanine are eluted in this order with the resolution between these peaks being not less than Amount (z) of guanine = MS/MT MS: Amount (mg) of guanine taken × AT/AS × 2/5 17. System repeatability: When the test is repeated 6 times with 10 mL of the standard solution under the above operat- MT: Amount (mg) of Aciclovir taken Operating conditions— Detector, column, column temperature, mobile phase, and flow rate: Proceed as directed in the operating conditions in the Assay. Time span of measurement: About 8 times as long as the retention time of aciclovir, beginning after the solvent peak. System suitability— System performance: Proceed as directed in the system suitability in the Assay. Test for required detectability: To 1 mL of the sample solution add the mobile phase to make 100 mL, and use this solution as the solution for system suitability test. Pipet 1 mL of the solution for system suitability test, and add the mobile phase to make exactly 10 mL. Confirm that the peak area of aciclovir obtained with 10 mL of this solution is equivalent to 7 to 13z of that with 10 mL of the solution for system suitability test. System repeatability: When the test is repeated 6 times with 10 mL of the standard solution under the above operat-ing conditions, the relative standard deviation of the peak area of guanine is not more than 2.0z. Water <2.48> Not more than 6.0z (50 mg, coulometric titration). Residue on ignition <2.44> Not more than 0.1z (1 g)."
}
},
{
"@type": "AssaySpecification",
"testName": {
"en": "Assay"
},
"testType": "TestType-Assay",
"testConditions": {
"en": "Weigh accurately about 20 mg each of Aciclovir and Aciclovir RS (separately determine the water <2.48> in the same manner as Aciclovir), dissolve each in 1 mL of dilute sodium hydroxide TS, add the mobile phase to make exactly 20 mL each, and use these solutions as the sample solution and the standard solution, respectively. Perform the test with exactly 10 mL each of the sample solution and standard solution as directed under Liquid Chromatography <2.01> according to the following conditions, and determine the peak areas, AT and AS, of aciclovir in each solution. ing conditions, the relative standard deviation of the peak area of aciclovir is not more than 1.0z."
}
}
],
"storageConditions": {
"en": "Containers—Well-closed contain-ers."
}
}