Japanese Pharmacopoeia · JP18
Insulin Glargine (Genetical Recombination)
インスリン グラルギン(遺伝子組換え)
JP18-insulin-glargine-genetical-recombination
Definition
Insulin Glargine (Genetical Recombination) is a recombinant human insulin analogue, being substitut- JP XVIII Official Monographs / Insulin Glargine (Genetical Recombination) 1163 ed asparagine residue with glycine residue at 21st of A chain and added two arginine residues at C-terminal of B chain. It is a peptide composed with A chain consist-ing of 21 amino acid residues and B chain consisting of 32 amino acid residues. It contains not less than 94.
Appearance
Insulin Glargine (Genetical Recombination) occurs as a white powder. It is practically insoluble in water and in ethanol (99.5). It is sparingly soluble in 0.01 mol/L hydrochloric acid TS. It is hygroscopic. It is gradually decomposed by light.
Test specifications
Identification
TestType-Identification
Keep the sample solution and standard solu-tion at 2 – 89C. Weigh a suitable amount of Insulin Glargine (Genetical Recombination) and Insulin Glargine RS, and dis-solve separately in 0.01 mol/L hydrochloric acid TS so that each mL contains 10.0 mg. Transfer 5 mL of these solutions into clean test tubes, add 1 mL of 1 mol/L tris buffer solu-tion (pH 7.5) and 100 mL of a solution of V8 protease for in-sulin glargine in 1 mol/L tris buffer solution (pH 7.5) (20 units/mL), allow to react at 35 – 379C for 3 hours, then add 2 mL of phosphoric acid to stop the reaction, and use these solutions as the sample solution and the standard solution, respectively. Perform the test with exactly 50 mL each of the sample solution and standard solution as directed under Liq-uid Chromatography <2.01> according to the following con-ditions, and compare the chromatograms obtained from these solutions: The similar peaks appear at the same reten-tion times. Operating conditions— Detector: An ultraviolet absorption photometer (wave-length: 214 nm). Column: A stainless steel column 3 mm in inside diameter and 12.5 cm in length, packed with octadecylsilanized silica gel for liquid chromatography (4 mm in particle diameter). Column temperature: A constant temperature of about 359C. Mobile phase A: To 930 mL of a solution, prepared by dissolving 11.6 g of phosphoric acid and 42.1 g of sodium perchloric acid in 1600 mL of water, adjusting to pH 2.3 with triethylamine and adding water to make 2000 mL, add 70 mL of acetonitrile for liquid chromatography. Mobile phase B: To 430 mL of a solution, prepared by dis-solving 11.6 g of phosphoric acid and 42.1 g of sodium per-chloric acid in 1600 mL of water, adjusting to pH 2.3 with triethylamine and adding water to make 2000 mL, add 570 mL of acetonitrile for liquid chromatography. Flowing of mobile phase: Control the gradient by mixing the mobile phases A and B as follows. appear next to the first peak just after the solvent peak, are not more than 1.5, respectively, and the resolution between these peaks is not less than 3.4.
Purity
TestType-Purity
(1) Related substances—Perform the test with 5 mL of the sample solution obtained in the Assay as directed under Liquid Chromatography <2.01> according to the fol-lowing conditions. Determine each peak area by the auto-matic integration method, and calculate the amount of these peaks by the area percentage method: the amount of the peak other than insulin glargine is not more than 0.4z, and the total amount of the peaks other than insulin glargine is not more than 1.0z. Operating conditions— Detector, column, column temperature, mobile phases A and B, flowing of mobile phase, and flow rate: Proceed as directed in the operating conditions in the Assay. Time span of measurement: For 40 minutes after injec-tion, beginning after the solvent peak. System suitability— Test for required detectability: Pipet 1 mL of the sample solution, add 0.01 mol/L hydrochloric acid TS to make ex-actly 100 mL, and use this solution as the solution for system suitability test. Pipet 1 mL of the solution for system suitability test, add 0.01 mol/L hydrochloric acid TS to make exactly 10 mL. Confirm that the peak area of insulin glargine obtained with 5 mL of this solution is equivalent to 5 to 15z of that with 5 mL of the solution for system suitabil-ity test. System performance: When the procedure is run with 5 mL of the standard solution obtained in the Assay under the above operating conditions, the number of theoretical plates and the symmetry factor of the peak of insulin glargine are not less than 20,000 and not more than 1.8, respectively. System repeatability: When the test is repeated 6 times with 5 mL of the standard solution obtained in the Assay under the above operating conditions, the relative standard deviation of the peak area of insulin glargine is not more than 2.0z. High-molecular mass proteins—Keep the sample so-lution at 2 – 89C. Dissolve 15 mg of Insulin Glargine (Genet-ical Recombination) in 1.5 mL of 0.01 mol/L hydrochloric acid TS, add water to make 10 mL, and use this solution as the sample solution. Perform the test with 100 mL of the sample solution as directed under Liquid Chromatography <2.01> according to the following conditions. Determine each peak area by the automatic integration method, and calcu-late the amount of them by the area percentage method: the total amount of the peaks other than insulin glargine is not more than 0.3z. Operating conditions— Detector: An ultraviolet absorption photometer (wave-length: 276 nm). Column: Two stainless steel columns connected in series of 8 mm in inside diameter and 30 cm in length, packed with hydrophilic silica gel for liquid chromatography (5 mm in Time after injection 0 – 30 90 → 20 10 → 80 30 – 35 of sample (min) Mobile phase A (volz) Mobile phase B (volz) particle diameter). Column temperature: A constant temperature of about 259C. Mobile phase: To 400 mL of water add 300 mL of aceto-nitrile for liquid chromatography and 200 mL of acetic acid (100), adjust to pH 3.0 with ammonia solution (28), and add Flow rate: 0.55 mL per minute. System suitability— System performance: When the procedure is run with 50 mL of the standard solution under the above operating con-ditions, the symmetry factors of the two larger peaks, which water to make 1000 mL. Flow rate: Adjust so that the retention time of insulin glar-gine is about 35 minutes. Time span of measurement: From the retention time cor-responding to the exclusion volume of the size-exclusion column to the completion of the elution of insulin glargine. System suitability— Test for required detectability: To 1 mL of the sample so-lution add 0.01 mol/L hydrochloric acid TS to make 50 mL, the sample solution and standard solution as directed under Liquid Chromatography <2.01> according to the following conditions, and determine the peak areas, AT and AS, of insulin glargine in each solution. and use this solution as the solution for system suitability test. Pipet 1 mL of the solution for system suitability test, add 0.01 mol/L hydrochloric acid TS to make exactly 10 Amount (mg) of insulin glargine (C = MS × AT/AS H404N 72O78 S6) mL. Confirm that the peak area of insulin glargine obtained with 100 mL of this solution is equivalent to 5 to 15z of that with 100 mL of the solution for system suitability test. System performance: Heat 15 mg of Insulin Glargine (Genetical Recombination) at 1009C for 1.5 – 3 hours, then dissolve in 1.5 mL of 0.01 mol/L hydrochloric acid TS, and add water to make exactly 10 mL. When the procedure is run with 100 mL of this solution under the above operating con-ditions, the high-molecular mass protein and insulin glargine are eluted in this order with the resolution between these peaks is not less than 1.5. System repeatability: When the test is repeated 6 times with 100 mL of the solution for system suitability test under the above operating conditions, the relative standard devia-tion of the peak area of insulin glargine is not more than 2.0z. Other product-related impurities—Being specified separately when the drug is granted approval based on the Law. Host cell proteins—Being specified separately when the drug is granted approval based on the Law. Host cell DNA—Being specified separately when the drug is granted approval based on the Law. Water <2.48> Not more than 8.0z (90 mg, coulometric titration). MS: Amount (mg) of insulin glargine in 1 mL of the stand-ard solution Operating conditions— Detector: An ultraviolet absorption photometer (wave-length: 214 nm). Column: A stainless steel column 3 mm in inside diameter and 25 cm in length, packed with octadecylsilanized silica gel for liquid chromatography (4 mm in particle diameter). Column temperature: A constant temperature of about 359C. Mobile phase A: Dissolve 20.7 g of anhydrous sodium di-hydrogen phosphate in 900 mL of water, adjust to pH 2.5 with phosphoric acid, and add water to make 1000 mL. To 250 mL of this solution add 250 mL of acetonitrile for liquid chromatography, dissolve 18.4 g of sodium chloride in this solution, and add water to make 1000 mL. Mobile phase B: Dissolve 20.7 g of anhydrous sodium di-hydrogen phosphate in 900 mL of water, adjust to pH 2.5 with phosphoric acid, and add water to make 1000 mL. To 250 mL of this solution add 650 mL of acetonitrile for liquid chromatography, dissolve 3.2 g of sodium chloride in this solution, and add water to make 1000 mL. Flowing of mobile phase: Control the gradient by mixing the mobile phases A and B as directed in the following table. Bacterial endotoxins <4.01> Less than 10 EU/mg. Zinc content Weigh accurately about 45 mg of Insulin Time after injection of sample (min) Mobile phase A (volz) Mobile phase B (volz) Glargine (Genetical Recombination), dissolve in 0.01 mol/L hydrochloric acid TS to make exactly 50 mL. Pipet 10 mL of this solution, add 0.01 mol/L hydrochloric acid TS to make exactly 100 mL, and use this solution as the sample solution. Separately, take exactly a suitable amount of Standard Zinc Solution for Atomic Absorption Spectrophotometry, dilute with 0.01 mol/L hydrochloric acid TS to make three solu-tions containing 0.20 mg, 0.40 mg and 0.60 mg of zinc (Zn: 65.38) in each mL, respectively, and use these solutions as the standard solutions. Perform the test with the sample solution and standard solutions as directed under Atomic Absorption Spectrophotometry <2.23> according to the following conditions, and calculate the amount of zinc in the sample solution using a calibration curve obtained from the absorbances of the standard solutions: not more than 0.80z of zinc (Zn: 65.38), calculated on the anhydrous basis. Gas: Combustible gas—Acetylene. Supporting gas—Air. Lamp: Zinc hollow-cathode lamp. Wavelength: 213.9 nm.
Assay
TestType-Assay
Keep the sample solution and standard solution at 2 – 89C. Weigh accurately about 15 mg of Insulin Glargine (Genetical Recombination), dissolve in 1.5 mL of 0.01 mol/L hydrochloric acid TS, add water to make exactly 10 mL, and use this solution as the sample solution. Separately, dissolve Insulin Glargine RS in 0.01 mol/L hydrochloric acid TS so that each mL contains about 10 mg of insulin glargine, then exactly dilute with water so that each mL contains about 1.5 mg of insulin glargine, and use this solution as the standard solution. Perform the test with exactly 5 mL each of 0 – 20 96 → 83 4 → 17 20 – 30 83 → 63 17 → 37 30 – 40 63 → 96 37 → 4 Flow rate: 0.55 mL per minute (the retention time of insu-lin glargine is about 21 minutes). System suitability— System performance: When the procedure is run with 5 mL of the standard solution under the above operating condi-tions, the number of theoretical plates and the symmetry fac-tor of the peak of insulin glargine are not less than 20,000 and not more than 1.8, respectively. System repeatability: When the test is repeated 6 times with 5 mL of the standard solution under the above operating conditions, the relative standard deviation of the peak area of insulin glargine is not more than 2.0z.
No counterparts indexed yet — search this title across all datasets
View raw JSON-LD
{
"@context": "https://www.openphar.org/ontology/context/pharmacopoeia.jsonld",
"@id": "https://www.openphar.org/data/jp/biologicals/insulin-glargine-genetical-recombination",
"@type": "BiologicalSubstanceMonograph",
"prefLabel": {
"en": "Insulin Glargine (Genetical Recombination)",
"ja": "インスリン グラルギン(遺伝子組換え)"
},
"monographId": "JP18-insulin-glargine-genetical-recombination",
"publisher": "JP",
"status": "Official",
"version": "18",
"definition": {
"en": "Insulin Glargine (Genetical Recombination) is a recombinant human insulin analogue, being substitut- JP XVIII Official Monographs / Insulin Glargine (Genetical Recombination) 1163 ed asparagine residue with glycine residue at 21st of A chain and added two arginine residues at C-terminal of B chain. It is a peptide composed with A chain consist-ing of 21 amino acid residues and B chain consisting of 32 amino acid residues. It contains not less than 94."
},
"appearance": {
"en": "Insulin Glargine (Genetical Recombination) occurs as a white powder. It is practically insoluble in water and in ethanol (99.5). It is sparingly soluble in 0.01 mol/L hydrochloric acid TS. It is hygroscopic. It is gradually decomposed by light."
},
"testSpecification": [
{
"@type": "IdentificationSpecification",
"testName": {
"en": "Identification"
},
"testType": "TestType-Identification",
"testConditions": {
"en": "Keep the sample solution and standard solu-tion at 2 – 89C. Weigh a suitable amount of Insulin Glargine (Genetical Recombination) and Insulin Glargine RS, and dis-solve separately in 0.01 mol/L hydrochloric acid TS so that each mL contains 10.0 mg. Transfer 5 mL of these solutions into clean test tubes, add 1 mL of 1 mol/L tris buffer solu-tion (pH 7.5) and 100 mL of a solution of V8 protease for in-sulin glargine in 1 mol/L tris buffer solution (pH 7.5) (20 units/mL), allow to react at 35 – 379C for 3 hours, then add 2 mL of phosphoric acid to stop the reaction, and use these solutions as the sample solution and the standard solution, respectively. Perform the test with exactly 50 mL each of the sample solution and standard solution as directed under Liq-uid Chromatography <2.01> according to the following con-ditions, and compare the chromatograms obtained from these solutions: The similar peaks appear at the same reten-tion times. Operating conditions— Detector: An ultraviolet absorption photometer (wave-length: 214 nm). Column: A stainless steel column 3 mm in inside diameter and 12.5 cm in length, packed with octadecylsilanized silica gel for liquid chromatography (4 mm in particle diameter). Column temperature: A constant temperature of about 359C. Mobile phase A: To 930 mL of a solution, prepared by dissolving 11.6 g of phosphoric acid and 42.1 g of sodium perchloric acid in 1600 mL of water, adjusting to pH 2.3 with triethylamine and adding water to make 2000 mL, add 70 mL of acetonitrile for liquid chromatography. Mobile phase B: To 430 mL of a solution, prepared by dis-solving 11.6 g of phosphoric acid and 42.1 g of sodium per-chloric acid in 1600 mL of water, adjusting to pH 2.3 with triethylamine and adding water to make 2000 mL, add 570 mL of acetonitrile for liquid chromatography. Flowing of mobile phase: Control the gradient by mixing the mobile phases A and B as follows. appear next to the first peak just after the solvent peak, are not more than 1.5, respectively, and the resolution between these peaks is not less than 3.4."
}
},
{
"@type": "PuritySpecification",
"testName": {
"en": "Purity"
},
"testType": "TestType-Purity",
"testConditions": {
"en": "(1) Related substances—Perform the test with 5 mL of the sample solution obtained in the Assay as directed under Liquid Chromatography <2.01> according to the fol-lowing conditions. Determine each peak area by the auto-matic integration method, and calculate the amount of these peaks by the area percentage method: the amount of the peak other than insulin glargine is not more than 0.4z, and the total amount of the peaks other than insulin glargine is not more than 1.0z. Operating conditions— Detector, column, column temperature, mobile phases A and B, flowing of mobile phase, and flow rate: Proceed as directed in the operating conditions in the Assay. Time span of measurement: For 40 minutes after injec-tion, beginning after the solvent peak. System suitability— Test for required detectability: Pipet 1 mL of the sample solution, add 0.01 mol/L hydrochloric acid TS to make ex-actly 100 mL, and use this solution as the solution for system suitability test. Pipet 1 mL of the solution for system suitability test, add 0.01 mol/L hydrochloric acid TS to make exactly 10 mL. Confirm that the peak area of insulin glargine obtained with 5 mL of this solution is equivalent to 5 to 15z of that with 5 mL of the solution for system suitabil-ity test. System performance: When the procedure is run with 5 mL of the standard solution obtained in the Assay under the above operating conditions, the number of theoretical plates and the symmetry factor of the peak of insulin glargine are not less than 20,000 and not more than 1.8, respectively. System repeatability: When the test is repeated 6 times with 5 mL of the standard solution obtained in the Assay under the above operating conditions, the relative standard deviation of the peak area of insulin glargine is not more than 2.0z. High-molecular mass proteins—Keep the sample so-lution at 2 – 89C. Dissolve 15 mg of Insulin Glargine (Genet-ical Recombination) in 1.5 mL of 0.01 mol/L hydrochloric acid TS, add water to make 10 mL, and use this solution as the sample solution. Perform the test with 100 mL of the sample solution as directed under Liquid Chromatography <2.01> according to the following conditions. Determine each peak area by the automatic integration method, and calcu-late the amount of them by the area percentage method: the total amount of the peaks other than insulin glargine is not more than 0.3z. Operating conditions— Detector: An ultraviolet absorption photometer (wave-length: 276 nm). Column: Two stainless steel columns connected in series of 8 mm in inside diameter and 30 cm in length, packed with hydrophilic silica gel for liquid chromatography (5 mm in Time after injection 0 – 30 90 → 20 10 → 80 30 – 35 of sample (min) Mobile phase A (volz) Mobile phase B (volz) particle diameter). Column temperature: A constant temperature of about 259C. Mobile phase: To 400 mL of water add 300 mL of aceto-nitrile for liquid chromatography and 200 mL of acetic acid (100), adjust to pH 3.0 with ammonia solution (28), and add Flow rate: 0.55 mL per minute. System suitability— System performance: When the procedure is run with 50 mL of the standard solution under the above operating con-ditions, the symmetry factors of the two larger peaks, which water to make 1000 mL. Flow rate: Adjust so that the retention time of insulin glar-gine is about 35 minutes. Time span of measurement: From the retention time cor-responding to the exclusion volume of the size-exclusion column to the completion of the elution of insulin glargine. System suitability— Test for required detectability: To 1 mL of the sample so-lution add 0.01 mol/L hydrochloric acid TS to make 50 mL, the sample solution and standard solution as directed under Liquid Chromatography <2.01> according to the following conditions, and determine the peak areas, AT and AS, of insulin glargine in each solution. and use this solution as the solution for system suitability test. Pipet 1 mL of the solution for system suitability test, add 0.01 mol/L hydrochloric acid TS to make exactly 10 Amount (mg) of insulin glargine (C = MS × AT/AS H404N 72O78 S6) mL. Confirm that the peak area of insulin glargine obtained with 100 mL of this solution is equivalent to 5 to 15z of that with 100 mL of the solution for system suitability test. System performance: Heat 15 mg of Insulin Glargine (Genetical Recombination) at 1009C for 1.5 – 3 hours, then dissolve in 1.5 mL of 0.01 mol/L hydrochloric acid TS, and add water to make exactly 10 mL. When the procedure is run with 100 mL of this solution under the above operating con-ditions, the high-molecular mass protein and insulin glargine are eluted in this order with the resolution between these peaks is not less than 1.5. System repeatability: When the test is repeated 6 times with 100 mL of the solution for system suitability test under the above operating conditions, the relative standard devia-tion of the peak area of insulin glargine is not more than 2.0z. Other product-related impurities—Being specified separately when the drug is granted approval based on the Law. Host cell proteins—Being specified separately when the drug is granted approval based on the Law. Host cell DNA—Being specified separately when the drug is granted approval based on the Law. Water <2.48> Not more than 8.0z (90 mg, coulometric titration). MS: Amount (mg) of insulin glargine in 1 mL of the stand-ard solution Operating conditions— Detector: An ultraviolet absorption photometer (wave-length: 214 nm). Column: A stainless steel column 3 mm in inside diameter and 25 cm in length, packed with octadecylsilanized silica gel for liquid chromatography (4 mm in particle diameter). Column temperature: A constant temperature of about 359C. Mobile phase A: Dissolve 20.7 g of anhydrous sodium di-hydrogen phosphate in 900 mL of water, adjust to pH 2.5 with phosphoric acid, and add water to make 1000 mL. To 250 mL of this solution add 250 mL of acetonitrile for liquid chromatography, dissolve 18.4 g of sodium chloride in this solution, and add water to make 1000 mL. Mobile phase B: Dissolve 20.7 g of anhydrous sodium di-hydrogen phosphate in 900 mL of water, adjust to pH 2.5 with phosphoric acid, and add water to make 1000 mL. To 250 mL of this solution add 650 mL of acetonitrile for liquid chromatography, dissolve 3.2 g of sodium chloride in this solution, and add water to make 1000 mL. Flowing of mobile phase: Control the gradient by mixing the mobile phases A and B as directed in the following table. Bacterial endotoxins <4.01> Less than 10 EU/mg. Zinc content Weigh accurately about 45 mg of Insulin Time after injection of sample (min) Mobile phase A (volz) Mobile phase B (volz) Glargine (Genetical Recombination), dissolve in 0.01 mol/L hydrochloric acid TS to make exactly 50 mL. Pipet 10 mL of this solution, add 0.01 mol/L hydrochloric acid TS to make exactly 100 mL, and use this solution as the sample solution. Separately, take exactly a suitable amount of Standard Zinc Solution for Atomic Absorption Spectrophotometry, dilute with 0.01 mol/L hydrochloric acid TS to make three solu-tions containing 0.20 mg, 0.40 mg and 0.60 mg of zinc (Zn: 65.38) in each mL, respectively, and use these solutions as the standard solutions. Perform the test with the sample solution and standard solutions as directed under Atomic Absorption Spectrophotometry <2.23> according to the following conditions, and calculate the amount of zinc in the sample solution using a calibration curve obtained from the absorbances of the standard solutions: not more than 0.80z of zinc (Zn: 65.38), calculated on the anhydrous basis. Gas: Combustible gas—Acetylene. Supporting gas—Air. Lamp: Zinc hollow-cathode lamp. Wavelength: 213.9 nm."
}
},
{
"@type": "AssaySpecification",
"testName": {
"en": "Assay"
},
"testType": "TestType-Assay",
"testConditions": {
"en": "Keep the sample solution and standard solution at 2 – 89C. Weigh accurately about 15 mg of Insulin Glargine (Genetical Recombination), dissolve in 1.5 mL of 0.01 mol/L hydrochloric acid TS, add water to make exactly 10 mL, and use this solution as the sample solution. Separately, dissolve Insulin Glargine RS in 0.01 mol/L hydrochloric acid TS so that each mL contains about 10 mg of insulin glargine, then exactly dilute with water so that each mL contains about 1.5 mg of insulin glargine, and use this solution as the standard solution. Perform the test with exactly 5 mL each of 0 – 20 96 → 83 4 → 17 20 – 30 83 → 63 17 → 37 30 – 40 63 → 96 37 → 4 Flow rate: 0.55 mL per minute (the retention time of insu-lin glargine is about 21 minutes). System suitability— System performance: When the procedure is run with 5 mL of the standard solution under the above operating condi-tions, the number of theoretical plates and the symmetry fac-tor of the peak of insulin glargine are not less than 20,000 and not more than 1.8, respectively. System repeatability: When the test is repeated 6 times with 5 mL of the standard solution under the above operating conditions, the relative standard deviation of the peak area of insulin glargine is not more than 2.0z."
}
}
],
"storageConditions": {
"en": "Containers—Tight containers. Storage—Not exceeding -159C."
}
}