Japanese Pharmacopoeia · JP18

Insulin Aspart (Genetical Recombination)

インスリン アスパルト(遺伝子組換え)

JP18-insulin-aspart-genetical-recombination

JP

Appearance

Insulin Aspart (Genetical Recombination) oc-curs as a white powder. It is practically insoluble in water and in ethanol (95). It dissolves in 0.01 mol/L hydrochloric acid TS. It is hygroscopic.

Test specifications

Identification

TestType-Identification

Weigh a suitable amount of Insulin Aspart (Genetical Recombination), and dissolve in 0.01 mol/L hy-drochloric acid TS to make a solution so that each mL con-tains 2.0 mg. Separately, dissolve Insulin Aspart RS in 0.01 mol/L hydrochloric acid TS to make a solution so that each mL contains 2.0 mg. Transfer 25 mL each of these solutions into clean test tubes, add 100 mL of HEPES buffer solution (pH 7.5) and 20 mL of V8-protease TS, and allow to react at 259C for 6 hours. Then add 145 mL of ammonium sulfate buffer solution to stop the reaction, and use these solutions as the sample solution and the standard solution, respec-tively. Perform the test with exactly 50 mL each of the sam-ple solution and standard solution as directed under Liquid Chromatography <2.01> according to the following condi-tions, and compare the peak (peak 1) eluted just after the peak of the solvent and the succeeding three peaks (peaks 2, 3 and 4) with apparently higher peak height in the chromato-grams obtained from these solutions: the similar peaks are observed at the same retention times. Operating conditions— Detector: An ultraviolet absorption photometer (wave-length: 214 nm). Column: A stainless steel column 4.6 mm in inside diame-ter and 10 cm in length, packed with octadecylsilanized silica gel for liquid chromatography (not exceeding 5 mm in parti-cle diameter). Column temperature: A constant temperature of about 409C. Mobile phase A: A mixture of water, ammonium sulfate buffer solution and acetonitrile for liquid chromatography (7:2:1). Mobile phase B: A mixture of water, acetonitrile for liquid chromatography and ammonium sulfate buffer solution (2:2:1). Flowing of mobile phase: Control the gradient by mixing the mobile phases A and B as directed in the following table. Time after injection of sample (min) Mobile phase A (volz) Mobile phase B (volz) 0 – 60 90 → 30 10 → 70 60 – 65 30 → 0 70 → 100 65 – 70 Flow rate: 1 mL per minute. System suitability— System performance: When the procedure is run with 50 mL of the standard solution under the above operating con- ditions, the symmetry factors of the peaks 2 and 3 are not more than 1.5, respectively, and the resolution between these peaks is not less than 8.

Purity

TestType-Purity

(1) Related substances—Perform the test with 10 mL of the sample solution obtained in the Assay as directed under Liquid Chromatography <2.01> according to the fol-lowing conditions. Determine each peak area by the auto-matic integration method, and calculate the amounts of them by the area percentage method: the amount of the peak of B28isoAsp insulin aspart, having the relative retention time of about 0.9 to insulin aspart, is not more than 0.3z, the total amount of the peak of A21Asp insulin aspart and B3Asp insulin aspart, having the relative retention times of about 1.3, and the peak of B3isoAsp insulin aspart, having the relative retention time of about 1.5, is not more than 1.0z, and the total amount of the peaks other than the peaks mentioned above is not more than 0.5z. Operating conditions— Detector, column, column temperature, mobile phase A, mobile phase B, flowing of mobile phase and flow rate: Pro-ceed as directed in the operating conditions in the Assay. Time span of measurement: From 4 minutes to 50 minutes after injection of the sample solution. System suitability— System performance and system repeatability: Proceed as directed in the system suitability in the Assay. Test for required detectability: Pipet 5 mL of the solution for system suitability test obtained in the Assay, add 0.01 mol/L hydrochloric acid TS to make exactly 10 mL. Con-firm that the area percentage of the peak of B28isoAsp insu-lin aspart obtained with 10 mL of this solution is equivalent to 80 to 120z of that with 10 mL of the solution for system suitability test. High-molecular proteins—Store the sample solution at a temperature between 29C and 89C, and use within 48 hours after preparation. Dissolve 4 mg of Insulin Aspart (Genetical Recombination) in 1 mL of 0.01 mol/L hydro-chloric acid TS, and use this solution as the sample solution. Perform the test with 100 mL of the sample solution as di-rected under Liquid Chromatography <2.01> according to the following conditions, determine each peak area by the automatic integration method, and calculate the amounts of them by the area percentage method: the total amount of the peaks other than insulin aspart is not more than 0.3z. Operating conditions— Detector: An ultraviolet absorption photometer (wave-length: 276 nm). Column: A stainless steel column 7.8 mm in inside diame-ter and 30 cm in length, packed with hydrophilic silica gel for liquid chromatography (5 to 10 mm in particle diameter). Column temperature: A constant temperature of about 209C. Mobile phase: A mixture of a solution of L-arginine (1 in 1000), acetonitrile for liquid chromatography and acetic acid (100) (13:4:3). Flow rate: 0.5 mL per minute. Time span of measurement: From the retention time cor-responding to the exclusion volume of the size-exclusion column to the completion of the elution of insulin aspart. System suitability— Test for required detectability: Allow Insulin Aspart (Genetic Recombination) to stand at ordinary temperature for about 10 days, which results in containing about 0.4z of high-molecular proteins, dissolve in 0.01 mol/L hydrochlo-ride TS so that each mL contains about 4 mg of insulin aspart, and use this solution as the solution for system ‌suitability test. Store the solution for system suitability test at a temperature between 29C and 89C, and use within 7 days. Pipet 5 mL of the solution for system suitability test, and add 0.01 mol/L hydrochloric acid TS to make exactly 10 mL. Confirm that the area percentage of the peak of insulin aspart dimer obtained with 100 mL of this solution is equiva-lent to 80 to 120z of that with 100 mL of the solution for system suitability test. System performance: When the procedure is run with 100 mL of the solution for system suitability test under the above Mobile phase A: Dissolve 142.0 g of anhydrous sodium sulfate in water, add 13.5 mL of phosphoric acid, and add water to make 5 L. Adjust to pH 3.6 with sodium hydroxide TS. To 4500 mL of this solution add 500 mL of acetonitrile for liquid chromatography. Mobile phase B: A mixture of water and acetonitrile for liquid chromatography (1:1). Flowing of mobile phase: Control the gradient by mixing the mobile phases A and B as directed in the following table. operating conditions, insulin aspart polymer (retention time: 13 to 17 minutes), insulin aspart dimer (retention time: about 17.5 minutes) and insulin aspart (retention time: 18 to 20 Time after injection of sample (min) Mobile phase A (volz) Mobile phase B (volz) minutes) are eluted in this order, and determine the peak height of the dimer and the height of the bottom between the peaks of the dimer and the monomer: the peak-valley ratio is not less than 2.0. System repeatability: When the test is repeated 6 times with 100 mL of the solution for system suitability test under the above operating conditions, the relative standard devia-tion of the peak area of insulin aspart is not more than 2.0z. Host cell proteins—Being specified separately when the drug is granted approval based on the Law. Host cell DNA—Being specified separately when the drug is granted approval based on the Law. Loss on drying <2.41> Not more than 10.0z (0.2 g, 1059C, 24 hours). Residue on ignition <2.44> Not more than 6.0z (0.2 g).

Assay

TestType-Assay

Store the sample solution and the standard solution at a temperature between 29C and 89C, use the sample solu-tion within 24 hours after preparation, and use the standard solution within 48 hours after preparation. Weigh accurately a suitable amount of Insulin Aspart (Genetical Recombina-tion), dissolve in 0.01 mol/L hydrochloric acid TS so that each mL contains 4.0 mg, and use this solution as the sample solution. Separately, dissolve Insulin Aspart RS in 0.01 mol/L hydrochloric acid TS so that each mL contains 4.0 mg, and use this solution as the standard solution. Perform the test with exactly 10 mL each of the sample solution and standard solution as directed under Liquid Chromatography <2.01> according to the following conditions, and determine the total areas, AT and AS, of the peak of B28isoAsp insulin aspart (relative retention time to insulin aspart: about 0.9), the peak of insulin aspart (retention time: 20 to 24 minutes), the peak of A21Asp insulin aspart and B3Asp insulin aspart (usually eluted together having the relative retention time of about 1.3) and the peak of B3isoAsp insulin aspart (relative retention time: about 1.5) in each solution. Amount (mg) of insulin aspart (C256H381N65O79S6) = MS × AT/AS MS: Total amount (mg) of insulin aspart, B28isoAsp insu-lin aspart, A21Asp insulin aspart and B3Asp insulin aspart, and B3isoAsp insulin aspart in 1 mL of the standard solution Operating conditions— Detector: An ultraviolet absorption photometer (wave-length: 214 nm). Column: A stainless steel column 4.0 mm in inside diame-ter and 25 cm in length, packed with octadecylsilanized silica gel for liquid chromatography (not exceeding 5 mm in parti-cle diameter). Column temperature: A constant temperature of about 409C. 0 – 35 58 42 35 – 40 58 → 20 42 → 80 40 – 45 20 80 45 – 46 20 → 58 80 → 42 46 – 60 58 42 Flow rate: 1 mL per minute. System suitability— System performance: Dissolve Insulin Aspart (Genetical Recombination) in 0.01 mol/L sodium dihydrogen phos-phate TS (pH 7.5) so that each mL contains 8 mg, and allow to stand at ordinary temperature for 10 to 15 days. To 1 mL of this solution add 1 mL of 0.01 mol/L hydrochloric acid TS, allow to stand at ordinary temperature for 1 to 3 days, and use this solution as the solution for system suitability test. The solution for system suitability test contains 0.1 to 2.2z of B28isoAsp insulin aspart, and not less than 1z of B3Asp insulin aspart and A21Asp insulin aspart. Store the solution for system suitability test at a temperature between 29C and 89C, and use within 72 hours. When the procedure is run with 10 mL of the solution for system suitability test under the above operating conditions, B28isoAsp insulin aspart, insulin aspart, A21Asp insulin aspart and B3Asp in-sulin aspart, and B3isoAsp insulin aspart are eluted in this order with the resolution between the peak of insulin aspart and the peak of A21Asp insulin aspart and B3Asp insulin aspart being not less than 2.0. System repeatability: When the test is repeated 5 times with 10 mL of the standard solution under the above operat-ing conditions, the relative standard deviation of AS is not more than 1.5z.

No counterparts indexed yet — search this title across all datasets

View raw JSON-LD
{
  "@context": "https://www.openphar.org/ontology/context/pharmacopoeia.jsonld",
  "@id": "https://www.openphar.org/data/jp/biologicals/insulin-aspart-genetical-recombination",
  "@type": "BiologicalSubstanceMonograph",
  "prefLabel": {
    "en": "Insulin Aspart (Genetical Recombination)",
    "ja": "インスリン アスパルト(遺伝子組換え)"
  },
  "monographId": "JP18-insulin-aspart-genetical-recombination",
  "publisher": "JP",
  "status": "Official",
  "version": "18",
  "appearance": {
    "en": "Insulin Aspart (Genetical Recombination) oc-curs as a white powder. It is practically insoluble in water and in ethanol (95). It dissolves in 0.01 mol/L hydrochloric acid TS. It is hygroscopic."
  },
  "testSpecification": [
    {
      "@type": "IdentificationSpecification",
      "testName": {
        "en": "Identification"
      },
      "testType": "TestType-Identification",
      "testConditions": {
        "en": "Weigh a suitable amount of Insulin Aspart (Genetical Recombination), and dissolve in 0.01 mol/L hy-drochloric acid TS to make a solution so that each mL con-tains 2.0 mg. Separately, dissolve Insulin Aspart RS in 0.01 mol/L hydrochloric acid TS to make a solution so that each mL contains 2.0 mg. Transfer 25 mL each of these solutions into clean test tubes, add 100 mL of HEPES buffer solution (pH 7.5) and 20 mL of V8-protease TS, and allow to react at 259C for 6 hours. Then add 145 mL of ammonium sulfate buffer solution to stop the reaction, and use these solutions as the sample solution and the standard solution, respec-tively. Perform the test with exactly 50 mL each of the sam-ple solution and standard solution as directed under Liquid Chromatography <2.01> according to the following condi-tions, and compare the peak (peak 1) eluted just after the peak of the solvent and the succeeding three peaks (peaks 2, 3 and 4) with apparently higher peak height in the chromato-grams obtained from these solutions: the similar peaks are observed at the same retention times. Operating conditions— Detector: An ultraviolet absorption photometer (wave-length: 214 nm). Column: A stainless steel column 4.6 mm in inside diame-ter and 10 cm in length, packed with octadecylsilanized silica gel for liquid chromatography (not exceeding 5 mm in parti-cle diameter). Column temperature: A constant temperature of about 409C. Mobile phase A: A mixture of water, ammonium sulfate buffer solution and acetonitrile for liquid chromatography (7:2:1). Mobile phase B: A mixture of water, acetonitrile for liquid chromatography and ammonium sulfate buffer solution (2:2:1). Flowing of mobile phase: Control the gradient by mixing the mobile phases A and B as directed in the following table. Time after injection of sample (min) Mobile phase A (volz) Mobile phase B (volz) 0 – 60 90 → 30 10 → 70 60 – 65 30 → 0 70 → 100 65 – 70 Flow rate: 1 mL per minute. System suitability— System performance: When the procedure is run with 50 mL of the standard solution under the above operating con- ditions, the symmetry factors of the peaks 2 and 3 are not more than 1.5, respectively, and the resolution between these peaks is not less than 8."
      }
    },
    {
      "@type": "PuritySpecification",
      "testName": {
        "en": "Purity"
      },
      "testType": "TestType-Purity",
      "testConditions": {
        "en": "(1) Related substances—Perform the test with 10 mL of the sample solution obtained in the Assay as directed under Liquid Chromatography <2.01> according to the fol-lowing conditions. Determine each peak area by the auto-matic integration method, and calculate the amounts of them by the area percentage method: the amount of the peak of B28isoAsp insulin aspart, having the relative retention time of about 0.9 to insulin aspart, is not more than 0.3z, the total amount of the peak of A21Asp insulin aspart and B3Asp insulin aspart, having the relative retention times of about 1.3, and the peak of B3isoAsp insulin aspart, having the relative retention time of about 1.5, is not more than 1.0z, and the total amount of the peaks other than the peaks mentioned above is not more than 0.5z. Operating conditions— Detector, column, column temperature, mobile phase A, mobile phase B, flowing of mobile phase and flow rate: Pro-ceed as directed in the operating conditions in the Assay. Time span of measurement: From 4 minutes to 50 minutes after injection of the sample solution. System suitability— System performance and system repeatability: Proceed as directed in the system suitability in the Assay. Test for required detectability: Pipet 5 mL of the solution for system suitability test obtained in the Assay, add 0.01 mol/L hydrochloric acid TS to make exactly 10 mL. Con-firm that the area percentage of the peak of B28isoAsp insu-lin aspart obtained with 10 mL of this solution is equivalent to 80 to 120z of that with 10 mL of the solution for system suitability test. High-molecular proteins—Store the sample solution at a temperature between 29C and 89C, and use within 48 hours after preparation. Dissolve 4 mg of Insulin Aspart (Genetical Recombination) in 1 mL of 0.01 mol/L hydro-chloric acid TS, and use this solution as the sample solution. Perform the test with 100 mL of the sample solution as di-rected under Liquid Chromatography <2.01> according to the following conditions, determine each peak area by the automatic integration method, and calculate the amounts of them by the area percentage method: the total amount of the peaks other than insulin aspart is not more than 0.3z. Operating conditions— Detector: An ultraviolet absorption photometer (wave-length: 276 nm). Column: A stainless steel column 7.8 mm in inside diame-ter and 30 cm in length, packed with hydrophilic silica gel for liquid chromatography (5 to 10 mm in particle diameter). Column temperature: A constant temperature of about 209C. Mobile phase: A mixture of a solution of L-arginine (1 in 1000), acetonitrile for liquid chromatography and acetic acid (100) (13:4:3). Flow rate: 0.5 mL per minute. Time span of measurement: From the retention time cor-responding to the exclusion volume of the size-exclusion column to the completion of the elution of insulin aspart. System suitability— Test for required detectability: Allow Insulin Aspart (Genetic Recombination) to stand at ordinary temperature for about 10 days, which results in containing about 0.4z of high-molecular proteins, dissolve in 0.01 mol/L hydrochlo-ride TS so that each mL contains about 4 mg of insulin aspart, and use this solution as the solution for system ‌suitability test. Store the solution for system suitability test at a temperature between 29C and 89C, and use within 7 days. Pipet 5 mL of the solution for system suitability test, and add 0.01 mol/L hydrochloric acid TS to make exactly 10 mL. Confirm that the area percentage of the peak of insulin aspart dimer obtained with 100 mL of this solution is equiva-lent to 80 to 120z of that with 100 mL of the solution for system suitability test. System performance: When the procedure is run with 100 mL of the solution for system suitability test under the above Mobile phase A: Dissolve 142.0 g of anhydrous sodium sulfate in water, add 13.5 mL of phosphoric acid, and add water to make 5 L. Adjust to pH 3.6 with sodium hydroxide TS. To 4500 mL of this solution add 500 mL of acetonitrile for liquid chromatography. Mobile phase B: A mixture of water and acetonitrile for liquid chromatography (1:1). Flowing of mobile phase: Control the gradient by mixing the mobile phases A and B as directed in the following table. operating conditions, insulin aspart polymer (retention time: 13 to 17 minutes), insulin aspart dimer (retention time: about 17.5 minutes) and insulin aspart (retention time: 18 to 20 Time after injection of sample (min) Mobile phase A (volz) Mobile phase B (volz) minutes) are eluted in this order, and determine the peak height of the dimer and the height of the bottom between the peaks of the dimer and the monomer: the peak-valley ratio is not less than 2.0. System repeatability: When the test is repeated 6 times with 100 mL of the solution for system suitability test under the above operating conditions, the relative standard devia-tion of the peak area of insulin aspart is not more than 2.0z. Host cell proteins—Being specified separately when the drug is granted approval based on the Law. Host cell DNA—Being specified separately when the drug is granted approval based on the Law. Loss on drying <2.41> Not more than 10.0z (0.2 g, 1059C, 24 hours). Residue on ignition <2.44> Not more than 6.0z (0.2 g)."
      }
    },
    {
      "@type": "AssaySpecification",
      "testName": {
        "en": "Assay"
      },
      "testType": "TestType-Assay",
      "testConditions": {
        "en": "Store the sample solution and the standard solution at a temperature between 29C and 89C, use the sample solu-tion within 24 hours after preparation, and use the standard solution within 48 hours after preparation. Weigh accurately a suitable amount of Insulin Aspart (Genetical Recombina-tion), dissolve in 0.01 mol/L hydrochloric acid TS so that each mL contains 4.0 mg, and use this solution as the sample solution. Separately, dissolve Insulin Aspart RS in 0.01 mol/L hydrochloric acid TS so that each mL contains 4.0 mg, and use this solution as the standard solution. Perform the test with exactly 10 mL each of the sample solution and standard solution as directed under Liquid Chromatography <2.01> according to the following conditions, and determine the total areas, AT and AS, of the peak of B28isoAsp insulin aspart (relative retention time to insulin aspart: about 0.9), the peak of insulin aspart (retention time: 20 to 24 minutes), the peak of A21Asp insulin aspart and B3Asp insulin aspart (usually eluted together having the relative retention time of about 1.3) and the peak of B3isoAsp insulin aspart (relative retention time: about 1.5) in each solution. Amount (mg) of insulin aspart (C256H381N65O79S6) = MS × AT/AS MS: Total amount (mg) of insulin aspart, B28isoAsp insu-lin aspart, A21Asp insulin aspart and B3Asp insulin aspart, and B3isoAsp insulin aspart in 1 mL of the standard solution Operating conditions— Detector: An ultraviolet absorption photometer (wave-length: 214 nm). Column: A stainless steel column 4.0 mm in inside diame-ter and 25 cm in length, packed with octadecylsilanized silica gel for liquid chromatography (not exceeding 5 mm in parti-cle diameter). Column temperature: A constant temperature of about 409C. 0 – 35 58 42 35 – 40 58 → 20 42 → 80 40 – 45 20 80 45 – 46 20 → 58 80 → 42 46 – 60 58 42 Flow rate: 1 mL per minute. System suitability— System performance: Dissolve Insulin Aspart (Genetical Recombination) in 0.01 mol/L sodium dihydrogen phos-phate TS (pH 7.5) so that each mL contains 8 mg, and allow to stand at ordinary temperature for 10 to 15 days. To 1 mL of this solution add 1 mL of 0.01 mol/L hydrochloric acid TS, allow to stand at ordinary temperature for 1 to 3 days, and use this solution as the solution for system suitability test. The solution for system suitability test contains 0.1 to 2.2z of B28isoAsp insulin aspart, and not less than 1z of B3Asp insulin aspart and A21Asp insulin aspart. Store the solution for system suitability test at a temperature between 29C and 89C, and use within 72 hours. When the procedure is run with 10 mL of the solution for system suitability test under the above operating conditions, B28isoAsp insulin aspart, insulin aspart, A21Asp insulin aspart and B3Asp in-sulin aspart, and B3isoAsp insulin aspart are eluted in this order with the resolution between the peak of insulin aspart and the peak of A21Asp insulin aspart and B3Asp insulin aspart being not less than 2.0. System repeatability: When the test is repeated 5 times with 10 mL of the standard solution under the above operat-ing conditions, the relative standard deviation of AS is not more than 1.5z."
      }
    }
  ],
  "storageConditions": {
    "en": "Containers—Tight containers. Storage—Not exceeding -189C."
  }
}