Japanese Pharmacopoeia · JP18
Influenza HA Vaccine
インフルエンザ HA ワクチン
JP18-influenza-ha-vaccine
Definition
Influenza HA Vaccine is a liquid for injection con-taining hemagglutinin of influenza virus. It conforms to the requirements of Influenza HA Vaccine in the Minimum Requirements for Biological Products. Description Influenza HA Vaccine is a clear liquid or a slightly whitish turbid liquid. A chain C99H153N25O35S4: 2381.68 B chain C158H234N40O42S2: 3429.92 [11061-68-0] Insulin Human (Genetical Recombination) is a recombinant human insulin. It is a peptide composed of A chain consisting of 21 amino acid residues and B chain consisting of 30 amino acid residues. It contains not less than 27.
Appearance
Influenza HA Vaccine is a clear liquid or a slightly whitish turbid liquid. A chain C99H153N25O35S4: 2381.68 B chain C158H234N40O42S2: 3429.92 [11061-68-0] Insulin Human (Genetical Recombination) is a recombinant human insulin. It is a peptide composed of A chain consisting of 21 amino acid residues and B chain consisting of 30 amino acid residues. It contains not less than 27.5 Insulin Units per mg, calculated on the dried basis. Description Insulin Human (Genetical Recombination) occurs as a white powder. It is practically insoluble in water and in ethanol (95). It dissolves in 0.01 mol/L hydrochloric acid TS and in sodium hydroxide TS with decomposition. It is hygroscopic.
Test specifications
Identification
TestType-Identification
Weigh accurately a suitable amount of Insu-lin Human (Genetical Recombination), and dissolve in 0.01 mol/L hydrochloric acid TS to make a solution so that each mL contains 2.0 mg. Transfer 500 mL of this solution into a clean test tube, add 2.0 mL of HEPES buffer solution (pH 7.5) and 400 mL of V8-protease TS, incubate at 259C for 6 hours, then add 2.9 mL of ammonium sulfate buffer solu-tion to stop the reaction, and use this solution as the sample solution. Separately, proceed with Insulin Human RS in the same manner as above, and use this solution as the standard solution. Perform the test with 50 mL each of the sample so-lution and standard solution as directed under Liquid Chro-matography <2.01> according to the following conditions, and compare the chromatograms obtained from these solu-tions: a similar peak is observed at the same retention time in the both chromatograms. Operating conditions— Detector: An ultraviolet absorption photometer (wave-length: 214 nm). Column: A stainless steel column 4.6 mm in inside diame-ter and 10 cm in length, packed with octadecylsilanized silica gel for liquid chromatography (3 mm in particle diameter). Column temperature: A constant temperature of about 409C. Mobile phase A: A mixture of water, ammonium sulfate buffer solution and acetonitrile (7:2:1). Mobile phase B: A mixture of water, acetonitrile and am-monium sulfate buffer solution (2:2:1). Flowing of mobile phase: Change the mixing ratio of the mobile phase A and B linearly from 9:1 to 3:7 in 60 minutes after sample injection, further change to 0:10 linearly in 5 minutes, and then flow the mobile phase B only for 5 minutes. Flow rate: 1.0 mL per minute. System suitability— System performance: When the procedure is run with 50 mL of the standard solution under the above operating con- ditions, the symmetry factor of the two larger peaks which appear next to the first peak just after the solvent peak are not more than 1.5 respectively, and the resolution between these peaks is not less than 3.4.
Purity
TestType-Purity
(1) Related substances—Perform this procedure rapidly. Dissolve 7.5 mg of Insulin Human (Genetical Recombination) in 2 mL of 0.01 mol/L hydrochloric acid TS, and use this solution as the sample solution. Perform the test with 20 mL of the sample solution as directed under Liq-uid Chromatography <2.01> according to the following con-ditions, and determine the peak area of human insulin, A1, the peak area of the desamido substance having the relative retention time of about 1.3 to human insulin, AD, and the total area of the peaks other than the solvent peak, AT: the amounts of the desamido substance and related substances other than the desamido substance are not more than 2.0z, respectively. Previously, perform the test with 0.01 mol/L hydrochloric acid TS in the same manner to confirm the sol-vent peak. Amount (z) of the desamido substance = AD/AT × 100 Amount (z) of related substances other than the desamido substance = [{AT - (A1 + AD)}/AT] × 100 Operating conditions— Detector: An ultraviolet absorption photometer (wave-length: 214 nm). Column: A stainless steel column 4.6 mm in inside diame-ter and 25 cm in length, packed with octadecylsilanized silica gel for liquid chromatography (5 mm in particle diameter). Column temperature: A constant temperature of about 409C. Mobile phase A: A mixture of phosphoric acid-sodium sulfate buffer solution (pH 2.3) and acetonitrile for liquid chromatography (41:9). Mobile phase B: A mixture of phosphoric acid-sodium sul-fate buffer solution (pH 2.3) and acetonitrile for liquid chro-matography (1:1). Flowing of mobile phase: Flow a mixture of the mobile phase A and B (78:22) for 36 minutes before and after the sample injection, then change the mixing ratio to 33:67 linearly in 25 minutes, and maintain this ratio for 6 minutes. Then flow the first mixture (78:22) for the next 15 minutes. Adjust the mixing ratio of the first mixture so that the reten-tion time of human insulin is about 25 minutes. Flow rate: 1.0 mL per minute. Time span of measurement: For about 75 minutes after the sample is injected. System suitability— Test for required detectability: Confirm that the peak height of the desamido substance obtained with 20 mL of human insulin desamido substance-containing TS is between 30z and 70z of the full scale. System performance: When the procedure is run with 20 mL of human insulin desamido substance-containing TS under the above operating conditions, human insulin and human insulin desamido substance are eluted in this order with the resolution between these peaks being not less than 2.0, and the symmetry factor of the peak of human insulin is not more than 1.8. High-molecular mass proteins—Dissolve 4 mg of In-sulin Human (Genetical Recombination) in 1 mL of 0.01 mol/L hydrochloric acid TS. Perform the test with 100 mL of this solution as directed under Liquid Chromatography <2.01> according to the following conditions, and calculate each peak area: the total of areas of the peaks having smaller retention time than human insulin is not more than 1.0z of the total area of all peaks. Operating conditions— Detector: An ultraviolet absorption photometer (wave-length: 276 nm). Column: A stainless steel column 7.5 mm in inside diame-ter and 30 cm in length, packed with hydrophilic silica gel for liquid chromatography. Column temperature: A constant temperature of about 259C. Mobile phase: A mixture of a solution of L-arginine (1 in 1000), acetonitrile and acetic acid (100) (13:4:3). Flow rate: Adjust so that the retention time of human in-sulin is about 20 minutes. Time span of measurement: Until the peak of human insu-lin monomer has appeared. System suitability— Test for required detectability: Confirm that the peak height of the dimer obtained with 100 mL of human insulin dimer-containing TS is between 10z and 50z of the full scale. System performance: When the procedure is run with 100 mL of human insulin dimer-containing TS under the above operating conditions, polymer, dimer and monomer are eluted in this order, and the ratio, H1/H2, of the peak height of the dimer H1 to the height of the bottom between the peaks of the dimer and the monomer H2 is not less than 2.0. Product related impurities—Being specified sepa-rately when the drug is granted approval based on the Law. Process related impurities—Being specified sepa-rately when the drug is granted approval based on the Law. Loss on drying <2.41> Not more than 10.0z (0.2 g, 1059C, 24 hours). Bacterial endotoxins <4.01> Less than 10 EU/mg. Zinc content Weigh accurately about 50 mg of Insulin Hu-man (Genetical Recombination), and dissolve in 0.01 mol/L hydrochloric acid TS to make exactly 25 mL. If necessary, dilute with 0.01 mol/L hydrochloric acid TS to make a solu-tion so that each mL contains between 0.4 mg and 1.6 mg of zinc (Zn: 65.38), and use this solution as the sample solution. Separately, take exactly a suitable amount of Standard Zinc Solution for Atomic Absorption Spectrophotometry, dilute with 0.01 mol/L hydrochloric acid TS to make solutions containing 0.40 mg, 0.80 mg, 1.20 mg and 1.60 mg of zinc (Zn: 65.38) in each mL, respectively, and use these solutions as the standard solutions. Perform the test with the sample solution and standard solutions as directed under Atomic Absorption Spectrophotometry <2.23>, and calculate the amount of zinc (Zn: 65.38) in the sample solution by using a calibration curve obtained from the absorbances of the standard solutions: not more than 1.0z, calculated on the dried basis. Gas: Combustible gas—Acetylene. Supporting gas—Air. Lamp: Zinc hollow cathode lamp. Wavelength: 213.9 nm.
Assay
TestType-Assay
Perform this procedure quickly. Weigh accurately about 7.5 mg of Insulin Human (Genetical Recombination), dissolve in 0.01 mol/L hydrochloric acid TS to make exactly 5 mL, and use this solution as the sample solution. Sepa-rately, weigh accurately a suitable amount of Insulin Human RS, dissolve exactly in 0.01 mol/L hydrochloric acid TS to make a solution so that each mL contains about 40 Insulin Units, and use this solution as the standard solution. Per-form the test with exactly 20 mL each of the sample solution JP XVIII Official Monographs / Insulin Human (Genetical Recombination) Injection 1157 and standard solution as directed under Liquid Chromatog-raphy <2.01> according to the following conditions, and de-termine the peak areas of human insulin, ATI and ASI, and the peak areas of the desamido substance having the relative retention time of 1.3 to human insulin, ATD and ASD, respec-tively, of these solutions. Amount (Insulin Unit/mg) of human insulin (C257H383N65O77S6) = (MS × F )/D × (ATI + ATD)/(ASI + ASD) × 5/MT F: Labeled unit (Insulin Unit/mg) of Insulin Human RS D: Volume (mL) of 0.01 mol/L hydrochloric acid TS used to dissolve the reference standard MT: Amount (mg) of Insulin Human (Genetical Recombi-nation) taken, calculated on the dried basis MS: Amount (mg) of Insulin Human RS taken Operating conditions— Detector: An ultraviolet absorption photometer (wave-length: 214 nm). Column: A stainless steel column 4.6 mm in inside diame-ter and 15 cm in length, packed with octadecylsilanized silica gel for liquid chromatography (5 mm in particle diameter). Column temperature: A constant temperature of about 409C. Mobile phase: A mixture of phosphoric acid-sodium sul-fate buffer solution (pH 2.3) and acetonitrile for liquid chro-matography (3:1). Adjust the mixing ratio of the component of the mobile phase so that the retention time of human in-sulin is between 10 minutes and 17 minutes. Flow rate: 1.0 mL per minute. System suitability— System performance: When the procedure is run with 20 mL of human insulin desamido substance-containing TS under the above operating conditions, human insulin and human insulin desamido substance are eluted in this order with the resolution between these peaks being not less than 2.0, and the symmetry factor of the peak of human insulin is not more than 1.8. System repeatability: When the test is repeated 6 times with 20 mL of the standard solution under the above operat-ing conditions, the relative standard deviation of the peak areas of human insulin is not more than 1.6z.
No counterparts indexed yet — search this title across all datasets
View raw JSON-LD
{
"@context": "https://www.openphar.org/ontology/context/pharmacopoeia.jsonld",
"@id": "https://www.openphar.org/data/jp/biologicals/influenza-ha-vaccine",
"@type": "BiologicalSubstanceMonograph",
"prefLabel": {
"en": "Influenza HA Vaccine",
"ja": "インフルエンザ HA ワクチン"
},
"monographId": "JP18-influenza-ha-vaccine",
"publisher": "JP",
"status": "Official",
"version": "18",
"definition": {
"en": "Influenza HA Vaccine is a liquid for injection con-taining hemagglutinin of influenza virus. It conforms to the requirements of Influenza HA Vaccine in the Minimum Requirements for Biological Products. Description Influenza HA Vaccine is a clear liquid or a slightly whitish turbid liquid. A chain C99H153N25O35S4: 2381.68 B chain C158H234N40O42S2: 3429.92 [11061-68-0] Insulin Human (Genetical Recombination) is a recombinant human insulin. It is a peptide composed of A chain consisting of 21 amino acid residues and B chain consisting of 30 amino acid residues. It contains not less than 27."
},
"appearance": {
"en": "Influenza HA Vaccine is a clear liquid or a slightly whitish turbid liquid. A chain C99H153N25O35S4: 2381.68 B chain C158H234N40O42S2: 3429.92 [11061-68-0] Insulin Human (Genetical Recombination) is a recombinant human insulin. It is a peptide composed of A chain consisting of 21 amino acid residues and B chain consisting of 30 amino acid residues. It contains not less than 27.5 Insulin Units per mg, calculated on the dried basis. Description Insulin Human (Genetical Recombination) occurs as a white powder. It is practically insoluble in water and in ethanol (95). It dissolves in 0.01 mol/L hydrochloric acid TS and in sodium hydroxide TS with decomposition. It is hygroscopic."
},
"testSpecification": [
{
"@type": "IdentificationSpecification",
"testName": {
"en": "Identification"
},
"testType": "TestType-Identification",
"testConditions": {
"en": "Weigh accurately a suitable amount of Insu-lin Human (Genetical Recombination), and dissolve in 0.01 mol/L hydrochloric acid TS to make a solution so that each mL contains 2.0 mg. Transfer 500 mL of this solution into a clean test tube, add 2.0 mL of HEPES buffer solution (pH 7.5) and 400 mL of V8-protease TS, incubate at 259C for 6 hours, then add 2.9 mL of ammonium sulfate buffer solu-tion to stop the reaction, and use this solution as the sample solution. Separately, proceed with Insulin Human RS in the same manner as above, and use this solution as the standard solution. Perform the test with 50 mL each of the sample so-lution and standard solution as directed under Liquid Chro-matography <2.01> according to the following conditions, and compare the chromatograms obtained from these solu-tions: a similar peak is observed at the same retention time in the both chromatograms. Operating conditions— Detector: An ultraviolet absorption photometer (wave-length: 214 nm). Column: A stainless steel column 4.6 mm in inside diame-ter and 10 cm in length, packed with octadecylsilanized silica gel for liquid chromatography (3 mm in particle diameter). Column temperature: A constant temperature of about 409C. Mobile phase A: A mixture of water, ammonium sulfate buffer solution and acetonitrile (7:2:1). Mobile phase B: A mixture of water, acetonitrile and am-monium sulfate buffer solution (2:2:1). Flowing of mobile phase: Change the mixing ratio of the mobile phase A and B linearly from 9:1 to 3:7 in 60 minutes after sample injection, further change to 0:10 linearly in 5 minutes, and then flow the mobile phase B only for 5 minutes. Flow rate: 1.0 mL per minute. System suitability— System performance: When the procedure is run with 50 mL of the standard solution under the above operating con- ditions, the symmetry factor of the two larger peaks which appear next to the first peak just after the solvent peak are not more than 1.5 respectively, and the resolution between these peaks is not less than 3.4."
}
},
{
"@type": "PuritySpecification",
"testName": {
"en": "Purity"
},
"testType": "TestType-Purity",
"testConditions": {
"en": "(1) Related substances—Perform this procedure rapidly. Dissolve 7.5 mg of Insulin Human (Genetical Recombination) in 2 mL of 0.01 mol/L hydrochloric acid TS, and use this solution as the sample solution. Perform the test with 20 mL of the sample solution as directed under Liq-uid Chromatography <2.01> according to the following con-ditions, and determine the peak area of human insulin, A1, the peak area of the desamido substance having the relative retention time of about 1.3 to human insulin, AD, and the total area of the peaks other than the solvent peak, AT: the amounts of the desamido substance and related substances other than the desamido substance are not more than 2.0z, respectively. Previously, perform the test with 0.01 mol/L hydrochloric acid TS in the same manner to confirm the sol-vent peak. Amount (z) of the desamido substance = AD/AT × 100 Amount (z) of related substances other than the desamido substance = [{AT - (A1 + AD)}/AT] × 100 Operating conditions— Detector: An ultraviolet absorption photometer (wave-length: 214 nm). Column: A stainless steel column 4.6 mm in inside diame-ter and 25 cm in length, packed with octadecylsilanized silica gel for liquid chromatography (5 mm in particle diameter). Column temperature: A constant temperature of about 409C. Mobile phase A: A mixture of phosphoric acid-sodium sulfate buffer solution (pH 2.3) and acetonitrile for liquid chromatography (41:9). Mobile phase B: A mixture of phosphoric acid-sodium sul-fate buffer solution (pH 2.3) and acetonitrile for liquid chro-matography (1:1). Flowing of mobile phase: Flow a mixture of the mobile phase A and B (78:22) for 36 minutes before and after the sample injection, then change the mixing ratio to 33:67 linearly in 25 minutes, and maintain this ratio for 6 minutes. Then flow the first mixture (78:22) for the next 15 minutes. Adjust the mixing ratio of the first mixture so that the reten-tion time of human insulin is about 25 minutes. Flow rate: 1.0 mL per minute. Time span of measurement: For about 75 minutes after the sample is injected. System suitability— Test for required detectability: Confirm that the peak height of the desamido substance obtained with 20 mL of human insulin desamido substance-containing TS is between 30z and 70z of the full scale. System performance: When the procedure is run with 20 mL of human insulin desamido substance-containing TS under the above operating conditions, human insulin and human insulin desamido substance are eluted in this order with the resolution between these peaks being not less than 2.0, and the symmetry factor of the peak of human insulin is not more than 1.8. High-molecular mass proteins—Dissolve 4 mg of In-sulin Human (Genetical Recombination) in 1 mL of 0.01 mol/L hydrochloric acid TS. Perform the test with 100 mL of this solution as directed under Liquid Chromatography <2.01> according to the following conditions, and calculate each peak area: the total of areas of the peaks having smaller retention time than human insulin is not more than 1.0z of the total area of all peaks. Operating conditions— Detector: An ultraviolet absorption photometer (wave-length: 276 nm). Column: A stainless steel column 7.5 mm in inside diame-ter and 30 cm in length, packed with hydrophilic silica gel for liquid chromatography. Column temperature: A constant temperature of about 259C. Mobile phase: A mixture of a solution of L-arginine (1 in 1000), acetonitrile and acetic acid (100) (13:4:3). Flow rate: Adjust so that the retention time of human in-sulin is about 20 minutes. Time span of measurement: Until the peak of human insu-lin monomer has appeared. System suitability— Test for required detectability: Confirm that the peak height of the dimer obtained with 100 mL of human insulin dimer-containing TS is between 10z and 50z of the full scale. System performance: When the procedure is run with 100 mL of human insulin dimer-containing TS under the above operating conditions, polymer, dimer and monomer are eluted in this order, and the ratio, H1/H2, of the peak height of the dimer H1 to the height of the bottom between the peaks of the dimer and the monomer H2 is not less than 2.0. Product related impurities—Being specified sepa-rately when the drug is granted approval based on the Law. Process related impurities—Being specified sepa-rately when the drug is granted approval based on the Law. Loss on drying <2.41> Not more than 10.0z (0.2 g, 1059C, 24 hours). Bacterial endotoxins <4.01> Less than 10 EU/mg. Zinc content Weigh accurately about 50 mg of Insulin Hu-man (Genetical Recombination), and dissolve in 0.01 mol/L hydrochloric acid TS to make exactly 25 mL. If necessary, dilute with 0.01 mol/L hydrochloric acid TS to make a solu-tion so that each mL contains between 0.4 mg and 1.6 mg of zinc (Zn: 65.38), and use this solution as the sample solution. Separately, take exactly a suitable amount of Standard Zinc Solution for Atomic Absorption Spectrophotometry, dilute with 0.01 mol/L hydrochloric acid TS to make solutions containing 0.40 mg, 0.80 mg, 1.20 mg and 1.60 mg of zinc (Zn: 65.38) in each mL, respectively, and use these solutions as the standard solutions. Perform the test with the sample solution and standard solutions as directed under Atomic Absorption Spectrophotometry <2.23>, and calculate the amount of zinc (Zn: 65.38) in the sample solution by using a calibration curve obtained from the absorbances of the standard solutions: not more than 1.0z, calculated on the dried basis. Gas: Combustible gas—Acetylene. Supporting gas—Air. Lamp: Zinc hollow cathode lamp. Wavelength: 213.9 nm."
}
},
{
"@type": "AssaySpecification",
"testName": {
"en": "Assay"
},
"testType": "TestType-Assay",
"testConditions": {
"en": "Perform this procedure quickly. Weigh accurately about 7.5 mg of Insulin Human (Genetical Recombination), dissolve in 0.01 mol/L hydrochloric acid TS to make exactly 5 mL, and use this solution as the sample solution. Sepa-rately, weigh accurately a suitable amount of Insulin Human RS, dissolve exactly in 0.01 mol/L hydrochloric acid TS to make a solution so that each mL contains about 40 Insulin Units, and use this solution as the standard solution. Per-form the test with exactly 20 mL each of the sample solution JP XVIII Official Monographs / Insulin Human (Genetical Recombination) Injection 1157 and standard solution as directed under Liquid Chromatog-raphy <2.01> according to the following conditions, and de-termine the peak areas of human insulin, ATI and ASI, and the peak areas of the desamido substance having the relative retention time of 1.3 to human insulin, ATD and ASD, respec-tively, of these solutions. Amount (Insulin Unit/mg) of human insulin (C257H383N65O77S6) = (MS × F )/D × (ATI + ATD)/(ASI + ASD) × 5/MT F: Labeled unit (Insulin Unit/mg) of Insulin Human RS D: Volume (mL) of 0.01 mol/L hydrochloric acid TS used to dissolve the reference standard MT: Amount (mg) of Insulin Human (Genetical Recombi-nation) taken, calculated on the dried basis MS: Amount (mg) of Insulin Human RS taken Operating conditions— Detector: An ultraviolet absorption photometer (wave-length: 214 nm). Column: A stainless steel column 4.6 mm in inside diame-ter and 15 cm in length, packed with octadecylsilanized silica gel for liquid chromatography (5 mm in particle diameter). Column temperature: A constant temperature of about 409C. Mobile phase: A mixture of phosphoric acid-sodium sul-fate buffer solution (pH 2.3) and acetonitrile for liquid chro-matography (3:1). Adjust the mixing ratio of the component of the mobile phase so that the retention time of human in-sulin is between 10 minutes and 17 minutes. Flow rate: 1.0 mL per minute. System suitability— System performance: When the procedure is run with 20 mL of human insulin desamido substance-containing TS under the above operating conditions, human insulin and human insulin desamido substance are eluted in this order with the resolution between these peaks being not less than 2.0, and the symmetry factor of the peak of human insulin is not more than 1.8. System repeatability: When the test is repeated 6 times with 20 mL of the standard solution under the above operat-ing conditions, the relative standard deviation of the peak areas of human insulin is not more than 1.6z."
}
}
],
"storageConditions": {
"en": "Containers—Tight containers. Storage—Not exceeding -209C."
}
}