Japanese Pharmacopoeia · JP18
L-Arginine
L-アルギニン
JP18-l-arginine
- Formula
- C6H14N4O2
- Mw
- 174.2
- Version
- 18
Definition
L-Arginine, when dried, contains not less than 98.
Appearance
L-Arginine occurs as white, crystals or crystal-line powder. It has a characteristic odor. It is freely soluble in water and in formic acid, and practi-cally insoluble in ethanol (99.5). It dissolves in dilute hydrochloric acid. It is hygroscopic.
Test specifications
Identification
TestType-Identification
Determine the infrared absorption spectrum of previously dried L-Arginine as directed in the potassium bromide disk method under Infrared Spectrophotometry <2.25>, and compare the spectrum with the Reference Spec- trum: both spectra exhibit similar intensities of absorption at the same wave numbers. D Optical rotation <2.49> [a]20: +26.9 – +27.99(after dry-ing, 2 g, 6 mol/L hydrochloric acid TS, 25 mL, 100 mm). pH <2.54> The pH of a solution prepared by dissolving 1.0 g of L-Arginine in 10 mL of water is between 10.5 and 12.0.
Purity
TestType-Purity
(1) Clarity and color of solution—A solution ob-tained by dissolving 1.0 g of L-Arginine in 10 mL of water is clear and colorless. Chloride <1.03>—Perform the test with 0.5 g of L-Arginine. Prepare the control solution with 0.30 mL of 0.01 mol/L hydrochloric acid VS (not more than 0.021z). Sulfate <1.14>—Perform the test with 0.6 g of L-Arginine. Prepare the control solution with 0.35 mL of 0.005 mol/L sulfuric acid VS (not more than 0.028z). Ammonium <1.02>—Perform the test with 0.25 g of L-Arginine, using the distillation under reduced pressure. Prepare the control solution with 5.0 mL of Standard Am-monium Solution (not more than 0.02z). Heavy metals <1.07>—Dissolve 2.0 g of L-Arginine in 30 mL of water, add 1 drop of phenolphthalein TS, neutral- ize with dilute hydrochloric acid, add 2 mL of dilute acetic acid and water to make 50 mL, and perform the test. Pre-pare the control solution with 2.0 mL of Standard Lead So-lution (not more than 10 ppm). Iron <1.10>—Prepare the test solution with 1.0 g of L-Arginine according to Method 1, and perform the test according to Method A. Prepare the control solution with 1.0 mL of Standard Iron Solution (not more than 10 ppm). Related substances—Dissolve 0.10 g of L-Arginine in 10 mL of water, and use this solution as the sample solution. Pipet 1 mL of the sample solution, and add water to make exactly 50 mL. Pipet 2 mL of this solution, add water to make exactly 20 mL, and use this solution as the standard solution. Perform the test with these solutions as directed under Thin-layer Chromatography <2.03>. Spot 5 mL each of the sample solution and standard solution on a plate of silica gel for thin-layer chromatography. Develop the plate with a mixture of 2-propanol and ammonia solution (28) (7:3) to a distance of about 10 cm, and dry the plate at 809C for 30 minutes. Spray evenly ninhydrin-butanol TS on the plate, and heat the plate at 809C for 10 minutes: the spot other than the principal spot obtained from the sample solution is not more intense than the spot from the standard solution. Loss on drying <2.41> Not more than 0.30z (1 g, 1059C, 3 hours). Residue on ignition <2.44> Not more than 0.1z (1 g).
Assay
TestType-Assay
Weigh accurately about 80 mg of L-Arginine, previ-ously dried, dissolve in 3 mL of formic acid, add 50 mL of acetic acid (100), and titrate <2.50> with 0.1 mol/L perchloric acid VS (potentiometric titration). Perform a blank determi-nation in the same manner, and make any necessary correc-tion. Each mL of 0.1 mol/L perchloric acid VS = 8.710 mg of C6H14N4O2
No counterparts indexed yet — search this title across all datasets
View raw JSON-LD
{
"@context": "https://www.openphar.org/ontology/context/pharmacopoeia.jsonld",
"@id": "https://www.openphar.org/data/jp/amino-acids/l-arginine",
"@type": "AminoAcidMonograph",
"prefLabel": {
"en": "L-Arginine",
"ja": "L-アルギニン"
},
"monographId": "JP18-l-arginine",
"publisher": "JP",
"status": "Official",
"version": "18",
"molecularFormula": "C6H14N4O2",
"molecularWeight": 174.2,
"definition": {
"en": "L-Arginine, when dried, contains not less than 98."
},
"appearance": {
"en": "L-Arginine occurs as white, crystals or crystal-line powder. It has a characteristic odor. It is freely soluble in water and in formic acid, and practi-cally insoluble in ethanol (99.5). It dissolves in dilute hydrochloric acid. It is hygroscopic."
},
"testSpecification": [
{
"@type": "IdentificationSpecification",
"testName": {
"en": "Identification"
},
"testType": "TestType-Identification",
"testConditions": {
"en": "Determine the infrared absorption spectrum of previously dried L-Arginine as directed in the potassium bromide disk method under Infrared Spectrophotometry <2.25>, and compare the spectrum with the Reference Spec- trum: both spectra exhibit similar intensities of absorption at the same wave numbers. D Optical rotation <2.49> [a]20: +26.9 – +27.99(after dry-ing, 2 g, 6 mol/L hydrochloric acid TS, 25 mL, 100 mm). pH <2.54> The pH of a solution prepared by dissolving 1.0 g of L-Arginine in 10 mL of water is between 10.5 and 12.0."
}
},
{
"@type": "PuritySpecification",
"testName": {
"en": "Purity"
},
"testType": "TestType-Purity",
"testConditions": {
"en": "(1) Clarity and color of solution—A solution ob-tained by dissolving 1.0 g of L-Arginine in 10 mL of water is clear and colorless. Chloride <1.03>—Perform the test with 0.5 g of L-Arginine. Prepare the control solution with 0.30 mL of 0.01 mol/L hydrochloric acid VS (not more than 0.021z). Sulfate <1.14>—Perform the test with 0.6 g of L-Arginine. Prepare the control solution with 0.35 mL of 0.005 mol/L sulfuric acid VS (not more than 0.028z). Ammonium <1.02>—Perform the test with 0.25 g of L-Arginine, using the distillation under reduced pressure. Prepare the control solution with 5.0 mL of Standard Am-monium Solution (not more than 0.02z). Heavy metals <1.07>—Dissolve 2.0 g of L-Arginine in 30 mL of water, add 1 drop of phenolphthalein TS, neutral- ize with dilute hydrochloric acid, add 2 mL of dilute acetic acid and water to make 50 mL, and perform the test. Pre-pare the control solution with 2.0 mL of Standard Lead So-lution (not more than 10 ppm). Iron <1.10>—Prepare the test solution with 1.0 g of L-Arginine according to Method 1, and perform the test according to Method A. Prepare the control solution with 1.0 mL of Standard Iron Solution (not more than 10 ppm). Related substances—Dissolve 0.10 g of L-Arginine in 10 mL of water, and use this solution as the sample solution. Pipet 1 mL of the sample solution, and add water to make exactly 50 mL. Pipet 2 mL of this solution, add water to make exactly 20 mL, and use this solution as the standard solution. Perform the test with these solutions as directed under Thin-layer Chromatography <2.03>. Spot 5 mL each of the sample solution and standard solution on a plate of silica gel for thin-layer chromatography. Develop the plate with a mixture of 2-propanol and ammonia solution (28) (7:3) to a distance of about 10 cm, and dry the plate at 809C for 30 minutes. Spray evenly ninhydrin-butanol TS on the plate, and heat the plate at 809C for 10 minutes: the spot other than the principal spot obtained from the sample solution is not more intense than the spot from the standard solution. Loss on drying <2.41> Not more than 0.30z (1 g, 1059C, 3 hours). Residue on ignition <2.44> Not more than 0.1z (1 g)."
}
},
{
"@type": "AssaySpecification",
"testName": {
"en": "Assay"
},
"testType": "TestType-Assay",
"testConditions": {
"en": "Weigh accurately about 80 mg of L-Arginine, previ-ously dried, dissolve in 3 mL of formic acid, add 50 mL of acetic acid (100), and titrate <2.50> with 0.1 mol/L perchloric acid VS (potentiometric titration). Perform a blank determi-nation in the same manner, and make any necessary correc-tion. Each mL of 0.1 mol/L perchloric acid VS = 8.710 mg of C6H14N4O2"
}
}
],
"storageConditions": {
"en": "Containers—Tight containers."
}
}