Indian Pharmacopoeia · ip-2022

Azelnidipine

IP

Definition

AZELNIDIPINE IP 2022 Other tests. Comply with the tests stated under Eye Drops. Assay. Determine by liquid chromatography (2.4.14). Test solution. Dilute a suitable volume of the eye drops containing 2.5 mg of Azelastine Hydrochloride to 50.0 ml with the mobile phase. Reference solution. A0.005 per cent w/v solution of azelastine hydrochloride IPRS in the mobile phase. Chromatographic system - a stainless steel column 25 cm x 4.6. mm, packed with cyanopropyl groups bonded to. porous silica (5 pm), - mobile phase: a mixture of 50 volumes of water, 50 volumes of acetonitrile, 0.4 volume of triethylamine and 0.2 volume of orthophosphoric acid, . - flow rate: 1 ml per minute, - spectrophotometer set at 210 nm, - injection volume: 20 pl. Inject the reference solution. The test is not valid unless the column efficiency is not less than 4500 theoretical plates, the tailing factor is not more than 2.0 and the relative standard deviation for replicate injections is not more than 2.0 per cent. Inject the reference solution and the test solution. Calculate the content of C22H24C1N3O,HC1. in the eye drops. Azelnidipine C33H34NA Mol. Wt. 582.7 Azelnidipine is 3-[l-(Diphenyhnethyl)azetidin-3-yl] 5-(l- methylethyl)(4RS)-2-amino-6-methyl -4-(3-nitrophenyl)-1,4- dihydropyridine-3,5-dicarboxylate. Azelnidipine contains not less than 99.0 per cent and not more than 101.0 per cent of C33H34 N4O6, calculated on the dried basis. Category. Calcium channel blocker Description. A light yellow to yellow crystalline powder. It shows polymorphism (2.5.11).

Monograph text

PREAMBLE

AZELNIDIPINE IP 2022 Other tests. Comply with the tests stated under Eye Drops. Assay. Determine by liquid chromatography (2.4.14). Test solution. Dilute a suitable volume of the eye drops containing 2.5 mg of Azelastine Hydrochloride to 50.0 ml with the mobile phase. Reference solution. A0.005 per cent w/v solution of azelastine hydrochloride IPRS in the mobile phase. Chromatographic system - a stainless steel column 25 cm x 4.6. mm, packed with cyanopropyl groups bonded to. porous silica (5 pm), - mobile phase: a mixture of 50 volumes of water, 50 volumes of acetonitrile, 0.4 volume of triethylamine and 0.2 volume of orthophosphoric acid, . - flow rate: 1 ml per minute, - spectrophotometer set at 210 nm, - injection volume: 20 pl. Inject the reference solution. The test is not valid unless the column efficiency is not less than 4500 theoretical plates, the tailing factor is not more than 2.0 and the relative standard deviation for replicate injections is not more than 2.0 per cent. Inject the reference solution and the test solution. Calculate the content of C22H24C1N3O,HC1. in the eye drops. Azelnidipine C33H34NA Mol. Wt. 582.7 Azelnidipine is 3-[l-(Diphenyhnethyl)azetidin-3-yl] 5-(l- methylethyl)(4RS)-2-amino-6-methyl -4-(3-nitrophenyl)-1,4- dihydropyridine-3,5-dicarboxylate. Azelnidipine contains not less than 99.0 per cent and not more than 101.0 per cent of C33H34 N4O6, calculated on the dried basis. Category. Calcium channel blocker Description. A light yellow to yellow crystalline powder. It shows polymorphism (2.5.11).

Identification

A. Determine by infrared adsorption spectrophotometry (2.4.6).Compare the spectrum with that obtained with azelnidipine IPRS or with the reference spectrum of azelnidipine. B. In the Assay, the principal peak in the chromatogram obtained with the test solution corresponds to the peak in the chromatogram obtained with the reference solution.

Tests

Related substances. Determine by liquid chromatography (2.4.14). Solvent mixture. 80 volumes of acetonitrile and 20 volumes of water. Test solution. Dissolve 100 mg of the substance under examination in the solvent mixture and dilute to 100.0 ml with the solvent mixture. Reference solution. Dilute 1.0 ml of the test solution to 100.0 ml with the solvent mixture. Chromatographic system - a stainless steel column 25 cm x 4.6 mm, packed with octadecylsilane bonded to porous silica (5 pm), - column temperature: 40°, - mobile phase: a mixture of 35 volumes of a buffer solution prepared by dissolving 3.0 g of potassium dihydrogen orthophosphate in 1000 ml of water, adjusted to pH 5.5 with orthophosphoric acid, 45 volumes of acetonitrile and 20 volumes of methanol, - flow rate: 1 ml per minute, - spectrophotometer set at 220 nm, - injection volume:10 pl. Inject the reference solution. The test is not valid unless the column efficiency is not less than 15000 theoretical plates, the tailing factor is not more than 1.5 and the relative standard deviation for replicate injections is not more than 1.0. Inject the reference solution and the test solution. Run the chromatogram twice the retention time of the principal peak for the test solution. The area of any secondary peak eluting at a relative retention time of about 0.5 is not more than 0.2 times the area of the principal peak in the chromatogram obtained with the reference solution (0.2 per cent), the area of any secondary peak eluting at a relative retention time of about 1.42 is not more than 0.3 times the area ofthe principal peak in the chromatogram obtained the with the reference solution (0.3 per cent), the area of any other secondary peak is not more than 0.1 times the area of the principal peak in the chromatogram obtained with the reference solution (0.1 per cent) and the sum of areas of all the secondary peaks is not AZELNIDIPINE more than 0.7 times the area, of the principal peak in .the chromatogram obtained with the reference solution (0.7 per cent). Ignore any peak with an area less than 0.05 times the area ofthe principal peak in the chromatogram obtained with the reference solution (0.05 per cent). Heavy metals (2.3.13). 2.0 g complies with the limit test for heavy metals, Method B (10 ppm). Sulphated ash (2.3.18). Not more than 0.1 percent. Loss on drying (2.4.19). Notmore than 0.5 percent, determined on 1.0 g by drying under vacuum at 70° for 5 hours. ' Assay. Determine by liquid chromatography (2.4.14) Solvent mixture. Equal volumes of water and acetonitrile. Test solution. Dissolve 20 mg of the substance under examination in the solvent mixture and dilute to 100.0 ml with the solvent mixture. Dilute 5.0 ml ofthe solution to 50.0 ml with the solvent mixture. Reference solution. A 0.002 per cent w/v solution of azelnidipine IPRS in the solvent mixture. Chromatographic system - a stainless steel column 25 cm x 4.6 mm, packed with octadecylsilane bonded to porous silica (5 pm), - mobile phase: A. a 0A)3'M potassium dihydrogen orthophosphate in water, B. acetonitrile, . . - a gradient programme using the conditions given below, - flow rate: 1 ml per minute, - spectrophotometer set at 256 nm, - injection volume: 20 jri. Time Mobile phase A Mobile phase B (in min.) (per cent v/v) (per cent v/y) 0 80 .20 . 5' ■ 80 20 12 30 70 20 30 70 ,25 80 . 20 ' .30 , 80 20.. Inject the reference solution.’ The test is not valid unless, the column efficiency is not less than 3000 theoretical plates, the tailing factor is not more than 2.0 arid the relative standard deviation for replicate injections is not more than 1.0 per cent; Inject the reference solution.and the test solution.. Calculate the content of C33H34 N4O6. Storage. Store protected from moisture, at a temperature not exceeding 30°;

Same substance in other pharmacopoeias

View raw JSON-LD
{
  "@id": "https://www.openphar.org/data/ip/monographs/azelnidipine",
  "@type": "IndexedMonograph",
  "prefLabel": {
    "en": "Azelnidipine"
  },
  "edition": "ip-2022",
  "category": "monographs",
  "definition": {
    "en": "AZELNIDIPINE\nIP 2022\nOther tests. Comply with the tests stated under Eye Drops.\nAssay. Determine by liquid chromatography (2.4.14).\nTest solution. Dilute a suitable volume of the eye drops \ncontaining 2.5 mg of Azelastine Hydrochloride to \n50.0 ml with the mobile phase.\nReference solution. A0.005 per cent w/v solution of azelastine \nhydrochloride IPRS in the mobile phase.\nChromatographic system\n- a stainless steel column 25 cm x 4.6. mm, packed with\ncyanopropyl groups bonded to. porous silica (5 pm),\n- mobile phase: a mixture of 50 volumes of water,\n50 volumes of acetonitrile, 0.4 volume of triethylamine \nand 0.2 volume of orthophosphoric acid,\n. \n- flow rate: 1 ml per minute,\n- spectrophotometer set at 210 nm,\n- injection volume: 20 pl.\nInject the reference solution. The test is not valid unless the \ncolumn efficiency is not less than 4500 theoretical plates, the \ntailing factor is not more than 2.0 and the relative standard \ndeviation for replicate injections is not more than 2.0 per cent.\nInject the reference solution and the test solution.\nCalculate the content of C22H24C1N3O,HC1. in the eye drops.\nAzelnidipine\nC33H34NA \nMol. Wt. 582.7\nAzelnidipine is 3-[l-(Diphenyhnethyl)azetidin-3-yl] 5-(l- \nmethylethyl)(4RS)-2-amino-6-methyl -4-(3-nitrophenyl)-1,4- \ndihydropyridine-3,5-dicarboxylate.\nAzelnidipine contains not less than 99.0 per cent and not \nmore than 101.0 per cent of C33H34 N4O6, calculated on the \ndried basis.\nCategory. Calcium channel blocker\nDescription. A light yellow to yellow crystalline powder. It \nshows polymorphism (2.5.11)."
  },
  "sections": [
    {
      "name": "PREAMBLE",
      "text": "AZELNIDIPINE\nIP 2022\nOther tests. Comply with the tests stated under Eye Drops.\nAssay. Determine by liquid chromatography (2.4.14).\nTest solution. Dilute a suitable volume of the eye drops \ncontaining 2.5 mg of Azelastine Hydrochloride to \n50.0 ml with the mobile phase.\nReference solution. A0.005 per cent w/v solution of azelastine \nhydrochloride IPRS in the mobile phase.\nChromatographic system\n- a stainless steel column 25 cm x 4.6. mm, packed with\ncyanopropyl groups bonded to. porous silica (5 pm),\n- mobile phase: a mixture of 50 volumes of water,\n50 volumes of acetonitrile, 0.4 volume of triethylamine \nand 0.2 volume of orthophosphoric acid,\n. \n- flow rate: 1 ml per minute,\n- spectrophotometer set at 210 nm,\n- injection volume: 20 pl.\nInject the reference solution. The test is not valid unless the \ncolumn efficiency is not less than 4500 theoretical plates, the \ntailing factor is not more than 2.0 and the relative standard \ndeviation for replicate injections is not more than 2.0 per cent.\nInject the reference solution and the test solution.\nCalculate the content of C22H24C1N3O,HC1. in the eye drops.\nAzelnidipine\nC33H34NA \nMol. Wt. 582.7\nAzelnidipine is 3-[l-(Diphenyhnethyl)azetidin-3-yl] 5-(l- \nmethylethyl)(4RS)-2-amino-6-methyl -4-(3-nitrophenyl)-1,4- \ndihydropyridine-3,5-dicarboxylate.\nAzelnidipine contains not less than 99.0 per cent and not \nmore than 101.0 per cent of C33H34 N4O6, calculated on the \ndried basis.\nCategory. Calcium channel blocker\nDescription. A light yellow to yellow crystalline powder. It \nshows polymorphism (2.5.11)."
    },
    {
      "name": "Identification",
      "text": "A. Determine by infrared adsorption spectrophotometry \n(2.4.6).Compare the spectrum with that obtained with \nazelnidipine IPRS or with the reference spectrum of \nazelnidipine.\nB. In the Assay, the principal peak in the chromatogram \nobtained with the test solution corresponds to the peak in the \nchromatogram obtained with the reference solution."
    },
    {
      "name": "Tests",
      "text": "Related substances. Determine by liquid chromatography \n(2.4.14).\nSolvent mixture. 80 volumes of acetonitrile and 20 volumes \nof water.\nTest solution. Dissolve 100 mg of the substance under \nexamination in the solvent mixture and dilute to 100.0 ml with \nthe solvent mixture.\nReference solution. Dilute 1.0 ml of the test solution to\n100.0 ml with the solvent mixture.\nChromatographic system\n- a stainless steel column 25 cm x 4.6 mm, packed with\noctadecylsilane bonded to porous silica (5 pm),\n- column temperature: 40°,\n- mobile phase: a mixture of 35 volumes of a buffer solution\nprepared by dissolving 3.0 g of potassium dihydrogen \northophosphate in 1000 ml of water, adjusted to pH 5.5 \nwith orthophosphoric acid, 45 volumes of acetonitrile \nand 20 volumes of methanol,\n- flow rate: 1 ml per minute,\n- spectrophotometer set at 220 nm,\n- injection volume:10 pl.\nInject the reference solution. The test is not valid unless the \ncolumn efficiency is not less than 15000 theoretical plates, the \ntailing factor is not more than 1.5 and the relative standard \ndeviation for replicate injections is not more than 1.0.\nInject the reference solution and the test solution. Run the \nchromatogram twice the retention time of the principal peak \nfor the test solution. The area of any secondary peak eluting \nat a relative retention time of about 0.5 is not more than 0.2 \ntimes the area of the principal peak in the chromatogram \nobtained with the reference solution (0.2 per cent), the area of \nany secondary peak eluting at a relative retention time of about\n1.42 is not more than 0.3 times the area ofthe principal peak in \nthe chromatogram obtained the with the reference solution \n(0.3 per cent), the area of any other secondary peak is not \nmore than 0.1 times the area of the principal peak in the \nchromatogram obtained with the reference solution (0.1 per \ncent) and the sum of areas of all the secondary peaks is not\nAZELNIDIPINE\nmore than 0.7 times the area, of the principal peak in .the \nchromatogram obtained with the reference solution (0.7 per \ncent). Ignore any peak with an area less than 0.05 times the \narea ofthe principal peak in the chromatogram obtained with \nthe reference solution (0.05 per cent).\nHeavy metals (2.3.13). 2.0 g complies with the limit test for \nheavy metals, Method B (10 ppm).\nSulphated ash (2.3.18). Not more than 0.1 percent.\nLoss on drying (2.4.19). Notmore than 0.5 percent, determined \non 1.0 g by drying under vacuum at 70° for 5 hours. '\nAssay. Determine by liquid chromatography (2.4.14)\nSolvent mixture. Equal volumes of water and acetonitrile.\nTest solution. Dissolve 20 mg of the substance under \nexamination in the solvent mixture and dilute to 100.0 ml with \nthe solvent mixture. Dilute 5.0 ml ofthe solution to 50.0 ml with \nthe solvent mixture.\nReference solution. A 0.002 per cent w/v solution of \nazelnidipine IPRS in the solvent mixture.\nChromatographic system\n- a stainless steel column 25 cm x 4.6 mm, packed with\noctadecylsilane bonded to porous silica (5 pm),\n- mobile phase: A. a 0A)3'M potassium dihydrogen\northophosphate in water,\nB. acetonitrile,\n. . - a gradient programme using the conditions given below,\n- flow rate: 1 ml per minute, \n- spectrophotometer set at 256 nm, \n- injection volume: 20 jri.\nTime\nMobile phase A\nMobile phase B\n(in min.)\n(per cent v/v)\n(per cent v/y)\n0\n80\n.20\n. 5' ■\n80\n20\n12\n30\n70\n20\n30\n70\n,25\n80 .\n20 '\n.30 ,\n80\n20..\nInject the reference solution.’ The test is not valid unless, the \ncolumn efficiency is not less than 3000 theoretical plates, the \ntailing factor is not more than 2.0 arid the relative standard \ndeviation for replicate injections is not more than 1.0 per cent;\nInject the reference solution.and the test solution..\nCalculate the content of C33H34 N4O6.\nStorage. Store protected from moisture, at a temperature not \nexceeding 30°;"
    }
  ]
}